NEWRelease 08 98,6% in English. Released on 20/11/2026: 40 documents, 841 pages and 85 new dossiers in English.View now ↗
UFOandUAPARCHIVE IN ENGLISH

Date: 23/03/2010 (D130) and 31/03/2010 (D136)Location: Reports prepared for the DIA's Acquisition Support Division (DWO-3), Washington, D.C., USA

DIA, 2010: AAWSAP studies assess controlling machines by thought and miniature biomedical implants

Two DIRDs from March 2010 review brain-machine interfaces and microfabricated biomedical sensors. The first concludes that muscle-activity sensors would be the practical option in the short term and that direct control by thought would require brain implants whose durability had not yet been demonstrated; the second describes implants and labs-on-a-chip.

Full dossierAAWSAP and advanced technologies
Event date
23/03/2010 (D130) and 31/03/2010 (D136)
Location
Reports prepared for the DIA's Acquisition Support Division (DWO-3), Washington, D.C., USA
Topic
AAWSAP and advanced technologies
Source agencies
DOW
Documents
2 documents · 81 pages
Reading time
168 min
Cover with the DIA seal and the title about controlling external devices without limb-operated interfaces.Cover of official reportPhysical page 1
Cover of official report · Defense Intelligence Agency (DIA) · Physical page 1 of the released file. Cover of the DIRD “Technological Approaches to Controlling External Devices in the Absence of Limb-Operated Interfaces,” dated March 23, 2010. D130, physical page 1. Documentary source ↗ · Enlarge image ↗

DOCUMENTARY SOURCES · DOW

What the records tell

These are two technical studies commissioned by the U.S. Defense Intelligence Agency (DIA) under the AAWSAP program. “Technological Approaches to Controlling External Devices in the Absence of Limb-Operated Interfaces,” dated March 23, 2010, has an author whose name was replaced with “AAP Person 73.” “Biosensors and BioMEMS: A Survey of the Present Field,” dated March 31, 2010, is by “AAP Person 65.” They are not sighting reports and do not mention UFOs or UAPs. They deal with the link between the human body and machines, a subject that appears in another DIRD in the program, on the cockpit of a future spacecraft.

The interface study sets an ambitious goal: operating remote machines “by thought” during normal activities, without a shielded room, without remaining motionless and without buttons, at a rate of at least 5 to 10 bits per second and with a response within 300 milliseconds. It reviews electroencephalography, magnetoencephalography, functional magnetic resonance imaging, near-infrared spectroscopy and implanted electrodes, with experiments on monkeys, rats and lampreys and clinical trials in people.

The conclusion is realistic. In the short term, the path would be to read electrical signals from the muscles with a few dry sensors, something that, according to the author, could surpass traditional controls within five years. In the long term, only invasive connections with individual neurons of the cortex or cerebellum would provide high capacity, but the implants of the time failed within a few weeks and two-way communication with the brain had not yet been demonstrated. The author suggests following the field closely.

The biosensor study is a survey of miniature medical devices: micromotors that reposition electrodes in the brain, insulin pumps, glucose sensors, retinal prostheses, ultrasound-powered stimulators and labs-on-a-chip, including a NASA-supported project to study cells in space. The conclusion predicts that miniaturization will advance down to the nanometer scale.

The two documents show the breadth of the program's subjects, which went beyond propulsion and included the interaction between pilot and machine. Neither deals with the effects of unknown phenomena on the human body, the subject of another DIRD in the program, on field effects on human tissue. The predictions are the authors' and reflect the state of research in 2010.

In discussing control by muscle signals (electromyography), the interface study says that a lightweight wireless system, with feedback on a head-up display, could be used to “untether the pilot from the cockpit.” It notes that recent work achieved 1 to 2 bits per second with minimal training, about four times the performance of a forehead electroencephalography sensor, still below the goal of 5 to 10 bits. It is an assessment based on published work; the text does not describe actual military use.

Among the experiments described is the neurochip of Eberhard Fetz and colleagues, implanted in freely moving monkeys: a self-contained, battery-powered device that simultaneously recorded neural and muscle activity and could stimulate the nervous system. The report also describes a hybrid system in which a mobile robot was guided by a lamprey brainstem kept in the laboratory, receiving signals from the robot's light sensors. These are experimental results with animals, cited from scientific publications.

The biosensor survey relies heavily on work from Arizona State University: many figures are credited to researchers at that university, such as Bruce Towe and J. Muthuswamy. Others come from university web pages, including a Brown University course site on retinal implants. It is a review of the literature and of academic outreach material, not a report on the program's own research.

The text recalls that, since the early days of the space program, NASA sought noninvasive ways to monitor astronauts' blood chemistry, and describes thermopile glucose sensors tested briefly in a pig, with the response to insulin recorded on a graph. The report itself admits that these sensors had stability problems in tissue and blood and lost sensitivity over time. These are third-party laboratory results, with no in-flight application described.

DIRECT READING OF THE FILE

The document, in the original

D130: translated in full are the cover, the masthead (page 2), the introduction (pages 5 and 6), and the conclusions (pages 33 and 34, without the references). Left out were the table of contents, the review of neural signals and technologies (pages 7 to 32), the section on implantable chips and arrays that precedes the conclusions, and the references. D136: translated in full are the cover, the masthead, the introduction (page 6), and the conclusion (page 45). Left out were the table of contents, the lists of figures, and the technical survey (pages 7 to 44). Neither of the two mentions UFOs or UAPs.

EXCERPT 1 · PHYSICAL PAGE 1

D130, physical page 1: cover

UNCLASSIFIED/ f 1"8rt 8Ffl@ltltl ~!HI 8HL\f 23 March 2010 !COD: 1 December 2009 DIA-08 -1003 -012 Defense Intelligence Reference Document Acquisition Threat Support Technological Approaches to Controlling External Devices in the Absence of Limb-Operated Interfaces UNCLASSIFIED/ /f8R 8FFI&I.t.k Wliili Qtlb¥

Editorial note: The marking “FOR OFFICIAL USE ONLY” appears struck through, which indicates that this restriction was removed upon release.

Check the original PDF
UNCLASSIFIED//[FOR OFFICIAL USE ONLY, struck through] Defense Intelligence Reference Document Acquisition Threat Support 23 March 2010 ICOD: 1 December 2009 DIA-08-1003-012 Technological Approaches to Controlling External Devices in the Absence of Limb-Operated Interfaces

View the document record ↗ · Physical page 1, counting the cover.

EXCERPT 2 · PHYSICAL PAGE 2

D130, physical page 2: masthead

UNCLASSIFIED//F8R 8FFl6i,t.k Miili Ot!P X Technological Approaches to Controlling External Devices in the Absence of Limb-Operated Interfaces Prepared by: Acquisition Support Division (DW0-3) Defense Warning Office Direct orate for Analysis Defense Intelligence Agency Author: AAP Person 73 Administrative Note COPYRIGHT WARN ING: Further disseminat ion of the photographs in this publication is not author ized. This product is one in a series of advanced technology reports produced in FY 2009 under the Defense Intelligence Agency, Defense Warning Office's Advanced Aerospace Weapon System Applications (AAWSA) Program. Comments or questions pertaining to this document should be addressed to !AAP Person 1 l AAWSA Program Manager, Defense Inte lligence Agency, ATTN: CLAR/DWO-3, Bldg 6000, Washington, DC 20340-5100 . UNCLASSIFIED/ /FQA &FFIGIAk Wiili ,u11a¥ ii

Editorial note: The names appear in the facsimile as boxes reading “AAP Person”.

Check the original PDF
Technological Approaches to Controlling External Devices in the Absence of Limb-Operated Interfaces Prepared by: Acquisition Support Division (DWO-3) Defense Warning Office Directorate for Analysis Defense Intelligence Agency Author: AAP Person 73 Administrative Note COPYRIGHT WARNING: Further dissemination of the photographs in this publication is not authorized. This product is one in a series of advanced technology reports produced in FY 2009 under the Defense Intelligence Agency, Defense Warning Office's Advanced Aerospace Weapon System Applications (AAWSA) Program. Comments or questions pertaining to this document should be addressed to [AAP Person 1], AAWSA Program Manager, Defense Intelligence Agency, ATTN: CLAR/DWO-3, Bldg 6000, Washington, DC 20340-5100.

View the document record ↗ · Physical page 2, counting the cover.

EXCERPT 3 · PHYSICAL PAGE 5

D130, physical pages 5 and 6: introduction (full text)

UNCLASSIFIED/ /P(Ht err1e1s1tt l!ISI!!! 9HL'I Technological Approaches to Controlling External Devices in the Absence of Limb-Operated Interfaces Introduction Since the advent of modern interactive control of computers, technologies have been sought to directly connect the biological and the physical to form a seamless entity. While science fiction explores the possibilities of shared consciousness between brains and mainframes, real-life scientists work toward an equally fantastic but more pedestrian goal of eliminating required electromechanical human-machine interfaces (HMis). Such technologies promise integration of thought and computer-controlled action, without the need for a limb-operated device to translate intent from physiological networks to physical circuits. This paper first briefly reviews underlying neural structure, function, and activity to provide background on the type of signals and the scale of temporal changes that arise from conscious control within the nervous system. A short primer on brain-machine interfaces (BMis) is included at the end of the background material. This is followed by a survey of the state-of-the-art detection and stimulation technologies available utilizing noninvasive and invasive methods, including several studies that exemplify research paths currently being undertaken. Discussion brings together elements of the technology survey, application limitations, a timeline for useful commercial deployment, and predicted future research directions. Two technology research paths are highlighted as the most probable to produce functionally useful devices (defined as nearly equal or even superior to the control capabilities of current HMis) in the near and far term. The technology endpoint this paper seeks is thought-based operation of remote machinery during normal human activities without mechanical device interaction-that is, control of external devices without the need to go to a specified location, such as a shielded room; without the need to remain perfectly motionless to reduce signal noise; and without the need for interaction with a normal electro-mechanical device, such as an i-Phone or other handheld device with buttons and trackballs. Data transfer rates are sought to exceed 5-10 bits/second to be useful for operation of complex devices; this rate range and above is referred to as high-bandwidth BMis. Response time for a 1-of-N selection of commands is targeted at 300 milliseconds or less. These are the operational parameters assumed for final implementation unless some limitation or supercapability is described. The paper concludes that noninvasive electrical monitoring of neural activity, primarily reading combined action of muscles and neurons, is the most promising commercial technology in the near term. Inherent limitations in the noninvasive electrical approach require future development of different research paths. The paper argues, mainly by eliminating other approaches, that the most probable technology in the long term involves invasive single­ neuron-based direct cortical connections to form a network of high-bandwidth duplex communication pathways. Currently the most promising technologies UNCLASSIFIED/ /FOR. OFFIGIAk Uii QPlk¥ V
Check the original PDF
Technological Approaches to Controlling External Devices in the Absence of Limb-Operated Interfaces Introduction Since the advent of modern interactive control of computers, technologies have been sought to directly connect the biological and the physical to form a seamless entity. While science fiction explores the possibilities of shared consciousness between brains and mainframes, real-life scientists work toward an equally fantastic but more pedestrian goal of eliminating required electromechanical human-machine interfaces (HMIs). Such technologies promise integration of thought and computer-controlled action, without the need for a limb-operated device to translate intent from physiological networks to physical circuits. This paper first briefly reviews underlying neural structure, function, and activity to provide background on the type of signals and the scale of temporal changes that arise from conscious control within the nervous system. A short primer on brain-machine interfaces (BMIs) is included at the end of the background material. This is followed by a survey of the state-of-the-art detection and stimulation technologies available utilizing noninvasive and invasive methods, including several studies that exemplify research paths currently being undertaken. Discussion brings together elements of the technology survey, application limitations, a timeline for useful commercial deployment, and predicted future research directions. Two technology research paths are highlighted as the most probable to produce functionally useful devices (defined as nearly equal or even superior to the control capabilities of current HMIs) in the near and far term. The technology endpoint this paper seeks is thought-based operation of remote machinery during normal human activities without mechanical device interaction-that is, control of external devices without the need to go to a specified location, such as a shielded room; without the need to remain perfectly motionless to reduce signal noise; and without the need for interaction with a normal electro-mechanical device, such as an i-Phone or other handheld device with buttons and trackballs. Data transfer rates are sought to exceed 5-10 bits/second to be useful for operation of complex devices; this rate range and above is referred to as high-bandwidth BMIs. Response time for a 1-of-N selection of commands is targeted at 300 milliseconds or less. These are the operational parameters assumed for final implementation unless some limitation or supercapability is described. The paper concludes that noninvasive electrical monitoring of neural activity, primarily reading combined action of muscles and neurons, is the most promising commercial technology in the near term. Inherent limitations in the noninvasive electrical approach require future development of different research paths. The paper argues, mainly by eliminating other approaches, that the most probable technology in the long term involves invasive single-neuron-based direct cortical connections to form a network of high-bandwidth duplex communication pathways. Currently the most promising technologies for robust construction of such an interface are optical stimulation, gating, and sensory devices, and chip-based electrode arrays that have been encased in ex-vivo-engineered neural tissue.

View the document record ↗ · Physical page 5, counting the cover.

EXCERPT 4 · PHYSICAL PAGE 33

D130, physical pages 33 and 34: conclusions (full text, without the references)

UNCLASSIFIED/ /POI': OPFIClltt U.!I! Oflt I • Developing complex neural networks on top of chips prior to implant. • Development of chronic electrode materials such as biopolymers that may be suitable for implant without an ex-vivo grown sheath. • Creating a biological to biological interface upon implant. This technol ogy does still rely on proximal sensing and stimulation of action potentials, but the neural tissue at the biological to physical interface is engineered rather than native, thus providing the opportunity to develop an effective bridging network to seamlessly integra te between the two systems. Development of such chronic implant capability could make feasible the nondestructive addition of cerebellar pathways for control activity that incorporates the huge potential of brain plasticity without adding significant cognitive burden on the prefrontal cortex. This would effectively turn the controlled device into part of the body as far as the brain is concerned. IMPLANTABLE CHIPS , LADDERS AND ARRAYS Research utilizing ECoG or neocortica l ladder array technology is the state of the art in neura l communication. However, stimulating nerves or peripheral pathways in this matter without damage to the receiving cells has proven difficult. Even in cochlear arrays, normal functioning of the surrounding tissue is lost and only a fraction of the quality of natural stimulation is available. Locating single neurons has also been challenging, though new electrode designs are being developed. These devices will continue to be useful for research applications such as better understanding of network structure and network function in conjunction with fMRI. BMI application will continue in the foreseeable future to be lim ited to instances where closed-loop with visual or other traditional sensory feedback is sufficient. Until new electrode designs develop a robust method of two-way communication with single neurons, they will not be the dominant BMI technology for use in normal, healthy individua ls. Conclusions The gamut of modern technologies that connect neural systems to physical systems has been surveyed, with attention to the underlying physiological signals. Many examples have been presented of studies illustrating the different research paths under way. Two of these technologies show the most promise of near term and long term successful high-ba ndwidth integration of brain and external systems. In the near term, noninvasive electrical sensors that primarily rely on EMG signals, but also include those weaker signals directly from neuro nal firing, are expected to dominate real-world applications. The decoding of these signals from just a handful of dry sensors can produce a large combination of on-off and variable strength control commands that should surpass the information capability of traditional electro­ mechanical interfaces in the next 5 years. This technology is limited, however, by the number of available EMG sites and the required coherent firing of very large numbers of neurons. To surpass these limitations, technologies capable of connections to individual neurons on a large scale will be necessary. In the far term, an invasive approach to establish high-bandwidth duplex communication networks, 5-20 bits/second, using interfaces with single neurons UNCLASSIFIED/ /P91l err1e1Jct U.!I! or•t I 27
Check the original PDF
Conclusions The gamut of modern technologies that connect neural systems to physical systems has been surveyed, with attention to the underlying physiological signals. Many examples have been presented of studies illustrating the different research paths under way. Two of these technologies show the most promise of near term and long term successful high-bandwidth integration of brain and external systems. In the near term, noninvasive electrical sensors that primarily rely on EMG signals, but also include those weaker signals directly from neuronal firing, are expected to dominate real-world applications. The decoding of these signals from just a handful of dry sensors can produce a large combination of on-off and variable strength control commands that should surpass the information capability of traditional electromechanical interfaces in the next 5 years. This technology is limited, however, by the number of available EMG sites and the required coherent firing of very large numbers of neurons. To surpass these limitations, technologies capable of connections to individual neurons on a large scale will be necessary. In the far term, an invasive approach to establish high-bandwidth duplex communication networks, 5-20 bits/second, using interfaces with single neurons directly in the cortex or cerebellum can take the fullest advantage of neural training and processing capability. Two research paths currently showing the most promise are optical interfaces and ex-vivo preparation of electrode arrays encased in engineered neural tissue. New electrode designs that could establish two-way communication with single neurons are also promising. The cerebellar connection point is extremely interesting to perhaps provide a connection that would effectively make the external device a part of the body as far as the brain is concerned. The current state of the art using metal electrode arrays for proximal stimulation and sensing does not appear to be advancing toward long duration viability as a commercial BMI without some unforeseen advance in two-way communication. Peripheral connections have some theoretical promise, but an example of such an implant in a human trial did not shown terrific success over several weeks it functioned. Implantation of cortical arrays in human trials has not been conducted on a wide scale for durations longer than a few weeks, and two-way electrical communication has yet to be realistically demonstrated, limiting the possible commercial application portfolio for this technology. Many possible research directions for disruptive advances have been presented. These areas and the physiological-physical interconnection field of study as a whole should be monitored regularly for advances, as well as the ancillary technology areas of brain plasticity, neural signal decoding, and general basic neuroscience. Advances in any and all of these areas could alter the future landscape of commercial applications and dramatically alter our understanding of what is possible through thought-directed control.

View the document record ↗ · Physical page 33, counting the cover.

EXCERPT 5 · PHYSICAL PAGE 1

D136, physical page 1: cover

UNCLASSIFIED/ /FQA QFFl&IAL t:l!H!! 8HL I Defense Intelligence Reference Document Acquisition Threat Support 31 March 2010 ICOD : 1 December 2009 DIA-08 - 1003-020 Biosensors and BioMEMS: A Survey of the Present Field UNCLASSIFIED/ /FQR QFFIQlal.ls W&&i &P•Llt

Editorial note: The marking “FOR OFFICIAL USE ONLY” appears struck through, which indicates that this restriction was removed upon release.

Check the original PDF
UNCLASSIFIED//[FOR OFFICIAL USE ONLY, struck through] Defense Intelligence Reference Document Acquisition Threat Support 31 March 2010 ICOD: 1 December 2009 DIA-08-1003-020 Biosensors and BioMEMS: A Survey of the Present Field

View the document record ↗ · Physical page 1, counting the cover.

EXCERPT 6 · PHYSICAL PAGE 2

D136, physical page 2: masthead

UNCLASSIFIED/ /POR: OPPl@IAL HS& 0Nk¥ Biosensors and BioMEMS: A Survey of the Present Field Prepared by: Acquisition Support Division (DW0-3) Defense Warning Office Directorate for Analysis Defense Intelligence Agency AAP Person 65 Author: Administrative Note COPYRIGHT WARNING: Further dissemination of the photographs in this publ ication is not author ized. This product is one in a series of advanced technology reports produced in FY 2009 under t he Defense Intelligence Agency, Defense Warning Office's Advanced Aerospace Weapon System Applications (AAWSA) Program. Comments or 1uestions pertaining to this document should be addressed to!AAP Person 1 , AAWSA Program Manager, Defense Intell igence Agency, ATTN: CLAR/DWO-3, Bldg 6000, Washington, DC 20340-5 100. UNCLASSIFIED/ {FOR OFFICIO! !!ii Qllk¥ ii

Editorial note: The names appear in the facsimile as boxes reading “AAP Person”.

Check the original PDF
Biosensors and BioMEMS: A Survey of the Present Field Prepared by: Acquisition Support Division (DWO-3) Defense Warning Office Directorate for Analysis Defense Intelligence Agency Author: AAP Person 65 Administrative Note COPYRIGHT WARNING: Further dissemination of the photographs in this publication is not authorized. This product is one in a series of advanced technology reports produced in FY 2009 under the Defense Intelligence Agency, Defense Warning Office's Advanced Aerospace Weapon System Applications (AAWSA) Program. Comments or questions pertaining to this document should be addressed to [AAP Person 1], AAWSA Program Manager, Defense Intelligence Agency, ATTN: CLAR/DWO-3, Bldg 6000, Washington, DC 20340-5100.

View the document record ↗ · Physical page 2, counting the cover.

EXCERPT 7 · PHYSICAL PAGE 6

D136, physical page 6: introduction (full text)

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ Biosensors and BioMEMS: A Survey of the Present Field Introduction Biomedical sensors and implantable devices employing micro­ electromechanical technology will be important to the future of biomedicine. Once just science fiction, the notion of a bionic man is now becoming a reality through the application of microscale technologies. Today it is not unusual to have a friend or family member who has an implantable device, such as a pacemaker, defibrillator, cochlear implant, biosensor, neurostimulator, or insulin pump. We have only seen the beginning of this technology development, and today's state-of-the-art implantable devices will be seen as crude and cumbersome tomorrow. With the rapid pace of development, it is probable that within the next two decades we will have as many medical treatments based on microdevices as there are pharmaceutical solutions today. This paper examines some of the most recent advances in the field, as well as the technologies that are likely to appear in the next few years. UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ vi
Check the original PDF
Biosensors and BioMEMS: A Survey of the Present Field Introduction Biomedical sensors and implantable devices employing microelectromechanical technology will be important to the future of biomedicine. Once just science fiction, the notion of a bionic man is now becoming a reality through the application of microscale technologies. Today it is not unusual to have a friend or family member who has an implantable device, such as a pacemaker, defibrillator, cochlear implant, biosensor, neurostimulator, or insulin pump. We have only seen the beginning of this technology development, and today's state-of-the-art implantable devices will be seen as crude and cumbersome tomorrow. With the rapid pace of development, it is probable that within the next two decades we will have as many medical treatments based on microdevices as there are pharmaceutical solutions today. This paper examines some of the most recent advances in the field, as well as the technologies that are likely to appear in the next few years.

View the document record ↗ · Physical page 6, counting the cover.

EXCERPT 8 · PHYSICAL PAGE 45

D136, physical page 45: conclusion (full text)

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ Conclusion MEMs are characterized by small dimensions, enabling new applications of physical principles to make sensors and actuators of superior characterist ics. Physical properties like surface tension and electrostatic charge dominate the operation of the devices, and new fabrication approaches are required to make them. The economic driving forces for this miniaturization are strong for health care and biology. Advanced fabrication processes are still being discovered to further miniaturize electromechanical systems and to bring us into the realm of nanomechanical systems (NEMS). The new class of NEMS devices are expected to provide a higher performance in applications such as sensors, medical diagnostics and in the electronics industry. Some devices will enable experiments on the structure and function of individual biomolecules. This field is expanding rapidly. Searches of the scientific literature show new ideas being developed in a number of laboratories throughout the world. UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ 39
Check the original PDF
Conclusion MEMs are characterized by small dimensions, enabling new applications of physical principles to make sensors and actuators of superior characteristics. Physical properties like surface tension and electrostatic charge dominate the operation of the devices, and new fabrication approaches are required to make them. The economic driving forces for this miniaturization are strong for health care and biology. Advanced fabrication processes are still being discovered to further miniaturize electromechanical systems and to bring us into the realm of nanomechanical systems (NEMS). The new class of NEMS devices are expected to provide a higher performance in applications such as sensors, medical diagnostics and in the electronics industry. Some devices will enable experiments on the structure and function of individual biomolecules. This field is expanding rapidly. Searches of the scientific literature show new ideas being developed in a number of laboratories throughout the world.

View the document record ↗ · Physical page 45, counting the cover.

EXCERPT 9 · PHYSICAL PAGE 3

D130, physical page 3: table of contents

UNCLASSIFIED/ /FOlil OFFI&I.t.k WIiii 8Plklf Contents Introduction ............................................................................................................ v Direct Neural Signals .............................................................................................. 1 Indirect Neuronal Signals - The BOLD Effect .......................................................... 3 Control of External Devices .................................................................................... 4 Noninvasive Technologies ...................................................................................... 6 EEG ..................................................................................................................... 7 MEG .................................................................................................................... 8 EMG .................................................................................................................... 9 MRI and fMRI ..................................................................................................... 9 NIRS .................................................................................................................... 10 Invasive Technologies .......................................................................................... 10 Open-Loop Direct Cortical Array Algorithm Modeling ....................................... 11 Closed-Loop Peripheral Arrays Utilizing Visual Feedback ................................. 13 MEMS, ECoG, and PSoC Circuitry ...................................................................... 14 Chronic Neural Implants and fMRI ................................................................... 16 New Electrode Designs ..................................................................................... 18 Hybrid Neuro-Robotic Systems for True Closed-Loop BMI ................................ 20 Trials Using Human Subjects ............................................................................ 22 Optical Stimulation of Action Potentials ........................................................... 23 Discussion ............................................................................................................ 23 Noninvasive Electrical Devices ......................................................................... 24 Noninvasive BOLD-Based devices ..................................................................... 25 Noninvasive Magnetic Devices ......................................................................... 26 Invasive Technologies - General, Optical, and Ex-Vivo Engineering ................. 26 Implantable Chips, Ladders, and Arrays ........................................................... 27 UNCLASSIFIED/ /rOR: orr1e1J1ct U91!! OHL¥ iii
Check the original PDF
Contents Introduction ... v Direct Neural Signals ... 1 Indirect Neuronal Signals – The BOLD Effect ... 3 Control of External Devices ... 4 Noninvasive Technologies ... 6 EEG ... 7 MEG ... 8 EMG ... 9 MRI and fMRI ... 9 NIRS ... 10 Invasive Technologies ... 10 Open-Loop Direct Cortical Array Algorithm Modeling ... 11 Closed-Loop Peripheral Arrays Utilizing Visual Feedback ... 13 MEMS, ECoG, and PSoC Circuitry ... 14 Chronic Neural Implants and fMRI ... 16 New Electrode Designs ... 18 Hybrid Neuro-Robotic Systems for True Closed-Loop BMI ... 20 Trials Using Human Subjects ... 22 Optical Stimulation of Action Potentials ... 23 Discussion ... 23 Noninvasive Electrical Devices ... 24 Noninvasive BOLD-Based devices ... 25 Noninvasive Magnetic Devices ... 26 Invasive Technologies – General, Optical, and Ex-Vivo Engineering ... 26 Implantable Chips, Ladders, and Arrays ... 27

View the document record ↗ · Physical page 3, counting the cover.

EXCERPT 10 · PHYSICAL PAGE 4

D130, physical page 4: table of contents (end) and list of figures

UNCLASSIFIED/ ,'FOR: 8ffl@IJllt t:191!! l>flt I Conclusions .......................................................................................................... 27 Figures Figure 1. Simplified Rendering of a Neuron ............................................................ 1 Figure 4. Experimental Overview of Brain-Controlled Robot in a Closed Loop Figure 9. Image Distortion and Custom Microwire Electrode Assembly to Figure 11. T2 Value Analysis Summary of T2 Values in All the Image Slices That Figure 2. The General Layout of a Closed-Loop Control Interface ........................... 5 Figure 3. Two Commercially Available EEG Sensors ................................................ 8 With Visual Feedback Experiment ......................................................... 13 Figure s. Schematic of the Neurochip Functional Blocks ...................................... 15 Figure 6. Implant Location ................................................................................... 16 Figure 7. Histology and Electrode Tracks ............................................................. 17 Figure 8. The Michigan Electrodes ........................................................................ 18 Improve It............................................................................................. 19 Figure 10. Example of T2 Variability ..................................................................... 19 Spanned the Electrode Arrays in All Animals ....................................... 20 Figure 12. A Hybrid Neuro-Robotic System .......................................................... 21 Figure 13. Experimental Arrangements ................................................................ 21 UNCLASSIFIED/ /FOil Offl@IJllL YSIE 8Htlf iv
Check the original PDF
Conclusions ... 27 Figures Figure 1. Simplified Rendering of a Neuron ... 1 Figure 2. The General Layout of a Closed-Loop Control Interface ... 5 Figure 3. Two Commercially Available EEG Sensors ... 8 Figure 4. Experimental Overview of Brain-Controlled Robot in a Closed Loop With Visual Feedback Experiment ... 13 Figure 5. Schematic of the Neurochip Functional Blocks ... 15 Figure 6. Implant Location ... 16 Figure 7. Histology and Electrode Tracks ... 17 Figure 8. The Michigan Electrodes ... 18 Figure 9. Image Distortion and Custom Microwire Electrode Assembly to Improve It ... 19 Figure 10. Example of T2 Variability ... 19 Figure 11. T2 Value Analysis Summary of T2 Values in All the Image Slices That Spanned the Electrode Arrays in All Animals ... 20 Figure 12. A Hybrid Neuro-Robotic System ... 21 Figure 13. Experimental Arrangements ... 21

View the document record ↗ · Physical page 4, counting the cover.

EXCERPT 11 · PHYSICAL PAGE 7

D130, physical page 7: direct neural signals and Figure 1

UNCLASSIFIED/ /POR: err1e1At l:191!! er•t I Direct Neural Signals The human nervous system has two classes of cells, neurons and glia. Based on all research to date, it is believed that signals within the network of neurons constitute the whole of information processing, with glial cells playing a purely supporting role. This neural doctrine has dominated research in BMI until recently and still constitutes the only major research path in direct technologies. Furthermore, all technologies directly measuring human neuronal action rely on detecting or influencing electrical activity of these cells; no current in situ research selectively affects neurotransmitter activity between local cells for the purpose of information exchange . Therefore, the focus for the foreseeable future will be on the electrical activity of neurons as the primary target of BMI. Neurons consist of four parts: axon, dendrites, cell body or soma, and pre-synaptic terminals. Electrical information is transmitted to the neuron through the dendrites, proceeds through the cell body, and leaves the cell through the axon at one or more pre-synaptic terminals. Neurons have one axon and from one to tens of thousands of dendrites. Figure 1. Simplified Rendering of a Neuron. The arrows indicate t he direction in which signals are conveyed . The single axon conducts signals away from the cell body, while the multiple dendrites receive signals from the axons of other neurons. The nerve terminals end on the dendrites or cell body of other neurons or on other cell types, such as muscle or gland cells. (Reference 1) Chemical details of how the action potentials travel through the cell or are transmitted across the synapse are not important to the current treatise, other than the distinction that in these biologically based electrical networks, ions of sodium, potassium, and chlorine move through the cell membranes perpendicular to the propagation of the action potential down the axon. This allows information to be transmitted faster than ions could flow down the axon. The propagation of information is similar to a wave traveling down a garden hose: quickly move one end of the hose back and forth with sufficient force, and a wave will travel to the other end of the hose; however, any part of the hose structure has only moved (nominally) perpendicular to the direction of wave propagation. In a similar fashion, ions flow through channels across the axon's cell membrane, changing the local membrane potential and thus propagating the electrical signal down the axon. UNCLASSIFIED/ ;'FOR OFFI&I.t.k Wliliii 8fslk¥ 1
Check the original PDF
Direct Neural Signals The human nervous system has two classes of cells, neurons and glia. Based on all research to date, it is believed that signals within the network of neurons constitute the whole of information processing, with glial cells playing a purely supporting role. This neural doctrine has dominated research in BMI until recently and still constitutes the only major research path in direct technologies. Furthermore, all technologies directly measuring human neuronal action rely on detecting or influencing electrical activity of these cells; no current in situ research selectively affects neurotransmitter activity between local cells for the purpose of information exchange. Therefore, the focus for the foreseeable future will be on the electrical activity of neurons as the primary target of BMI. Neurons consist of four parts: axon, dendrites, cell body or soma, and pre-synaptic terminals. Electrical information is transmitted to the neuron through the dendrites, proceeds through the cell body, and leaves the cell through the axon at one or more pre-synaptic terminals. Neurons have one axon and from one to tens of thousands of dendrites. [Figure 1 labels: cell body; dendrites; axon (less than 1 mm to more than 1 m in length); terminal branches of axon] Figure 1. Simplified Rendering of a Neuron. The arrows indicate the direction in which signals are conveyed. The single axon conducts signals away from the cell body, while the multiple dendrites receive signals from the axons of other neurons. The nerve terminals end on the dendrites or cell body of other neurons or on other cell types, such as muscle or gland cells. (Reference 1) Chemical details of how the action potentials travel through the cell or are transmitted across the synapse are not important to the current treatise, other than the distinction that in these biologically based electrical networks, ions of sodium, potassium, and chlorine move through the cell membranes perpendicular to the propagation of the action potential down the axon. This allows information to be transmitted faster than ions could flow down the axon. The propagation of information is similar to a wave traveling down a garden hose: quickly move one end of the hose back and forth with sufficient force, and a wave will travel to the other end of the hose; however, any part of the hose structure has only moved (nominally) perpendicular to the direction of wave propagation. In a similar fashion, ions flow through channels across the axon's cell membrane, changing the local membrane potential and thus propagating the electrical signal down the axon.

View the document record ↗ · Physical page 7, counting the cover.

EXCERPT 12 · PHYSICAL PAGE 8

D130, physical page 8: neural signal transmission compared with electrical circuits

UNCLASSIFIED/ ;'FOR OFFl&I.t.k Wliliii &NL¥ The signal transmission down the axon of a neuron is an all-or-nothing process. When the cell body is stimulated above threshold, the axon transmits the same action potential at the same speed and in the same direction, regardless of the extent above threshold or duration of the input . Action potentials have durations of 1-10 milliseconds. Input signals can result in transmission of multiple action potentials, and thus the frequency and number of neuronal firings do vary with the input. Neurons require some t ime to reset between firings, nominally the duration of the pulse for that axon, yielding a typical maximum firing rate of between 100 hertz (Hz) and 1 kilohertz (kHz). It is instructional at this point to contrast this mechanism with propagation of signals through a physical electrical circuit, the planned external portion of our BMI. In a copper wire, electrons carry the signal. Electrons drift along the signal path, but the signal itself moves as a compression wave rather than a transverse wave as in the biologica l system. Going back to our garden hose example, consider the hose now filled with small marbles: inserting a marble at one end will move each marble in the hose just a little, but very rapidly the last marble in line will pop out of the far end of the hose. As with the biological system, the signal is propagated to the far end of the hose by local actors rather than physical motion of a single ion or electron moving the whole distance. The underlying physics governing the signal transmission makes metallic and semimetallic circuits about a million times faster than the biological system. This difference in the carriers and underlying mechanisms of signal transmission between biological and physical circuits has so far prevented the invention of a direct connection between the two disparate systems. Instead, both noninvasive and invasive direct-detection technologies rely on placing physical sensors or transmitters in close proximity to the neurons of interest and utilizing classical electrodynamics to govern signal jump between the systems. Additionally, given the maximum typical firing rate for neurons of 1 kHz, sampling of action potentials at a few kHz will be fast enough to detect firing of any individual neuron, though super-sampling above 10 kHz can be used to reduce noise. Higher sampl ing frequencies also may be required if mult iple neurons are monitored and quantitative information about their relative firing sequence is desired . Frequencies of a 1 kHz or below are suffic ient to stimulate action potentials, and again, higher system frequency may be required for multiple neuron sequent ial stimulation. Finally, higher frequencies may be required if monitoring or stimulation of some aspect of signal transmission other than action potentials is sought, such as monitoring single ion channels. 1 There is currently no evidence that transduction frequencies above 100 kHz have any advantage in BMis, thus the main challenge is the connection dynamics, since even this ultra-maximum frequency is easily attainable with current electronic manufacturing technology. The human brain doesn't process information as a traditional computer does. Information is moved around through pathways and at certain neurons it is allowed or not allowed to pass based on excitory or inhibitory dendritic signals arriving before triggering of action potentials . Local groups of neurons can act nearly coherently, for example in volition of motor action like a hand movement. Detecting such coherent firing at nodes around the brain is robust both noninvasively and invasively, though 1 Technologies that monitor single ion channels on a neuronal membrane are important for researc h on neural function and neurotransm itter action . However, these devices are ultra -sensitive to physical motion, and have so far not proven useful in large scale information transfer required in BMis . UNCLASSIFIED/ /fOll OFFl@IAl W&lii OPU..¥ 2
Check the original PDF
The signal transmission down the axon of a neuron is an all-or-nothing process. When the cell body is stimulated above threshold, the axon transmits the same action potential at the same speed and in the same direction, regardless of the extent above threshold or duration of the input. Action potentials have durations of 1-10 milliseconds. Input signals can result in transmission of multiple action potentials, and thus the frequency and number of neuronal firings do vary with the input. Neurons require some time to reset between firings, nominally the duration of the pulse for that axon, yielding a typical maximum firing rate of between 100 hertz (Hz) and 1 kilohertz (kHz). It is instructional at this point to contrast this mechanism with propagation of signals through a physical electrical circuit, the planned external portion of our BMI. In a copper wire, electrons carry the signal. Electrons drift along the signal path, but the signal itself moves as a compression wave rather than a transverse wave as in the biological system. Going back to our garden hose example, consider the hose now filled with small marbles: inserting a marble at one end will move each marble in the hose just a little, but very rapidly the last marble in line will pop out of the far end of the hose. As with the biological system, the signal is propagated to the far end of the hose by local actors rather than physical motion of a single ion or electron moving the whole distance. The underlying physics governing the signal transmission makes metallic and semimetallic circuits about a million times faster than the biological system. This difference in the carriers and underlying mechanisms of signal transmission between biological and physical circuits has so far prevented the invention of a direct connection between the two disparate systems. Instead, both noninvasive and invasive direct-detection technologies rely on placing physical sensors or transmitters in close proximity to the neurons of interest and utilizing classical electrodynamics to govern signal jump between the systems. Additionally, given the maximum typical firing rate for neurons of 1 kHz, sampling of action potentials at a few kHz will be fast enough to detect firing of any individual neuron, though super-sampling above 10 kHz can be used to reduce noise. Higher sampling frequencies also may be required if multiple neurons are monitored and quantitative information about their relative firing sequence is desired. Frequencies of a 1 kHz or below are sufficient to stimulate action potentials, and again, higher system frequency may be required for multiple neuron sequential stimulation. Finally, higher frequencies may be required if monitoring or stimulation of some aspect of signal transmission other than action potentials is sought, such as monitoring single ion channels.¹ There is currently no evidence that transduction frequencies above 100 kHz have any advantage in BMIs, thus the main challenge is the connection dynamics, since even this ultra-maximum frequency is easily attainable with current electronic manufacturing technology. The human brain doesn't process information as a traditional computer does. Information is moved around through pathways and at certain neurons it is allowed or not allowed to pass based on excitory or inhibitory dendritic signals arriving before triggering of action potentials. Local groups of neurons can act nearly coherently, for example in volition of motor action like a hand movement. Detecting such coherent firing at nodes around the brain is robust both noninvasively and invasively, though ¹ Technologies that monitor single ion channels on a neuronal membrane are important for research on neural function and neurotransmitter action. However, these devices are ultra-sensitive to physical motion, and have so far not proven useful in large scale information transfer required in BMIs.

View the document record ↗ · Physical page 8, counting the cover.

EXCERPT 13 · PHYSICAL PAGE 9

D130, physical page 9: coherent firing signals, the P300 signal and notes 2 and 3

UNCLASSIFIED/ /FOR OFFl&IAk le.ISi: OPtklf noninvasive techniques currently cannot resolve firing sequences of individual neurons within such groups. Living neurons in an active tissue fire in the rest state. Changes in the frequency of these firings imply that a given neuron is currently involved in the processing of information. Bulk changes in local field potential oscillations imply that several neurons are active. This is the signal seen in the noninvasive direct-measurement techniques of electroencephalography (EEG) and magnetoencephalography (MEG). Movement as simple as an eye blink involves signal communication through a million neurons. Several locales in the nervous system thus offer the possibility of placement of an invasive monitoring device for detecting electrical activity associated with an eye blink or other signal of interest. Many other factors will influence the placement decision, but considering only catching the signal as an action potential, using any neuron along the complete pathway is equally as good, assuming detection of individual neuronal firing can be accomplished. Considering cortical placement of detection devices, the most common area of activity under study is the outer covering of gray matter of the cerebral cortex, the neocortex. The neocortex is about 2. 5 mm thick in humans and follows the ridges and fissures of the brain (gyri and sucli, respectively, or gyrus and sulcus, if singular). The neocortex is roughly divided into six layers and different cortical probes can concentrate on activity in different layers, or just measure the combined activity on the surface of the cortex, or the combined activity that is detectable noninvasively through the layers of tissue and bone of the cranium. Detecting single firings of individual neurons is a difficult process because the signals are weak to start with, and not isolated from the rest of the electrical activity within the brain. Large groups of coherent neurons, perhaps a few thousand to tens of thousands all firing at once in relation to an external event, are the most studied of single firing signals. 2 One of the most studied signals is the so-called P300 which occurs in many cognitive tasks (References 2-4). P300 is a term used to indicate a pulse signal from a large group of neurons that appears about 300 milliseconds after a stimulus event. Peaks that occur between 200 and 400 milliseconds are commonly grouped into the P300 category. The "P" stands for a positive measured voltage, while "N" signals are negative. 3 The P300 signal has been shown to be influenced by top-down executive function and is therefore a prime candidate for a trainable interface (Reference 5). Earlier signals, like PS0 and Nl00, are of a greater interest for differential diagnosis of pathology in current research. The preceding discussion is greatly simplified version of the electrical dynamics of neuronal firing and does not include differences between axon and dendrite signals, or the transmission of signals across the synapse. Complete discussion of underlying electrical signals in the nervous system can be found in (References 6, 7). Indirect Neuronal Signals - The BOLD Effect 2 Single firing signals here mean a single peak of combined electrical activity relative to an event. This is not necessarily the same as single firings of each neuron . 3 The literature is not consistent with plotting P signals up, and N signals down ; however, P peaks are always in the opposite direction of N peaks. UNCLASSIFIED/ /POil OPPl@IAL liSI!! 8HLY 3
Check the original PDF
noninvasive techniques currently cannot resolve firing sequences of individual neurons within such groups. Living neurons in an active tissue fire in the rest state. Changes in the frequency of these firings imply that a given neuron is currently involved in the processing of information. Bulk changes in local field potential oscillations imply that several neurons are active. This is the signal seen in the noninvasive direct-measurement techniques of electroencephalography (EEG) and magnetoencephalography (MEG). Movement as simple as an eye blink involves signal communication through a million neurons. Several locales in the nervous system thus offer the possibility of placement of an invasive monitoring device for detecting electrical activity associated with an eye blink or other signal of interest. Many other factors will influence the placement decision, but considering only catching the signal as an action potential, using any neuron along the complete pathway is equally as good, assuming detection of individual neuronal firing can be accomplished. Considering cortical placement of detection devices, the most common area of activity under study is the outer covering of gray matter of the cerebral cortex, the neocortex. The neocortex is about 2.5 mm thick in humans and follows the ridges and fissures of the brain (gyri and sucli, respectively, or gyrus and sulcus, if singular). The neocortex is roughly divided into six layers and different cortical probes can concentrate on activity in different layers, or just measure the combined activity on the surface of the cortex, or the combined activity that is detectable noninvasively through the layers of tissue and bone of the cranium. Detecting single firings of individual neurons is a difficult process because the signals are weak to start with, and not isolated from the rest of the electrical activity within the brain. Large groups of coherent neurons, perhaps a few thousand to tens of thousands all firing at once in relation to an external event, are the most studied of single firing signals.² One of the most studied signals is the so-called P300 which occurs in many cognitive tasks (References 2-4). P300 is a term used to indicate a pulse signal from a large group of neurons that appears about 300 milliseconds after a stimulus event. Peaks that occur between 200 and 400 milliseconds are commonly grouped into the P300 category. The "P" stands for a positive measured voltage, while "N" signals are negative.³ The P300 signal has been shown to be influenced by top-down executive function and is therefore a prime candidate for a trainable interface (Reference 5). Earlier signals, like P50 and N100, are of a greater interest for differential diagnosis of pathology in current research. The preceding discussion is greatly simplified version of the electrical dynamics of neuronal firing and does not include differences between axon and dendrite signals, or the transmission of signals across the synapse. Complete discussion of underlying electrical signals in the nervous system can be found in (References 6, 7). Indirect Neuronal Signals - The BOLD Effect ² Single firing signals here mean a single peak of combined electrical activity relative to an event. This is not necessarily the same as single firings of each neuron. ³ The literature is not consistent with plotting P signals up, and N signals down; however, P peaks are always in the opposite direction of N peaks.

View the document record ↗ · Physical page 9, counting the cover.

EXCERPT 14 · PHYSICAL PAGE 10

D130, physical page 10: the BOLD effect and control of external devices

UNCLASSIFIED/ /EOR OlifilEIAk W&li (UtLY The brain activity mentioned above is a complex chain of ionic motion within the central nervous system. Ionic production, release, and movement within and between cells all consume energy. This energy is supplied by the conversion of blood-borne oxyhemoglobin to deoxyhemoglobin. The rate of oxygen consumption in a localized volume varies based on local neural activity. The circulatory system compensates for changes in energy demand by increasing or decreasing both the flow rate and volume of blood, regionally and locally. Local energy demand, expressed in the capillary beds, will alter the rate at which oxygen is metabolized, called the cerebral rate of oxygen metabolism, abbreviated CMRO2. When brai n activity increases in a region, the circulatory response, called the hemodynamic response, will be increases in flow and volume, while the local areas increase CMRO2. The hemodynamic response consistently provides an excess of oxygen over what is required, and this results in some oxyhemoglobin traveling through the capillary bed and local venous structure without being converted into deoxyhemoglobin. Oxy- and deoxyhemoglobin have different magnetic susceptibilities, and different infrared spectra. The hemodynamic response, by changing the net ratio of oxy- to deoxyhemoglobin in the local venous structure, thus changes the local magnetic susceptib ility and local infrared resonance spectra around focused brain activity. This complex chain reaction is called the Blood Oxygen Level Dependent, or BOLD effect (Reference 8). The BOLD effect leads to a method to indirect ly measure the local brain activity by monitoring the hemodynamic response using Magnetic Resonance Imaging (MRI) or Near Infrared Spectroscopy (NIRS). The BOLD response to any event peaks about 4-6 seconds a~er the event occurs, lim iti ng the applications for which monitoring these signals and their associated delay may be useful, given the BMI operating parameters defined above Furthermore, person to person variation in distributed signals show significant differences in regions activated (Reference 9), though there is evidence that these inter-subject variations are stable intra-subject over time (Reference 10). Control of External Devices In general, there are two types of BMI design called open-loop and closed-loop. Open loop designs, those either detecting activity or providing stimulation, are important for BMI research and application other than the practical control of an external device. Closed-loop systems include both output signals from the brain to effect a change in the state of a device, and a stimulation channel, which can be used as feedback. In some system designs, the feedback can be via visual cues such as watching a display (Reference 11). Open- loop systems are important for BMI research and have application in sense replacement such as artificial hearing, or when extensive output signal processing is combined with external device state feedback (see remote robot operatio n below). For learning and fine, efficient control of external devices without significant external processing, closed-loop systems are typically needed . Several components constitute a general BMI system for control of an external device (Figure 2). As mentioned in the previous section, the interfaces where the inform ation signal makes the jump between biological and physical pathways are the most challenging part of the system. These connections can be placed to stimulate or read peripheral or cerebral neurons . The processing step could be as simple as amplification UNCLASSIFIED/ /FOR OFFl@IAL Y!H! 8HL1/ 4
Check the original PDF
The brain activity mentioned above is a complex chain of ionic motion within the central nervous system. Ionic production, release, and movement within and between cells all consume energy. This energy is supplied by the conversion of blood-borne oxyhemoglobin to deoxyhemoglobin. The rate of oxygen consumption in a localized volume varies based on local neural activity. The circulatory system compensates for changes in energy demand by increasing or decreasing both the flow rate and volume of blood, regionally and locally. Local energy demand, expressed in the capillary beds, will alter the rate at which oxygen is metabolized, called the cerebral rate of oxygen metabolism, abbreviated CMRO2. When brai n activity increases in a region, the circulatory response, called the hemodynamic response, will be increases in flow and volume, while the local areas increase CMRO2. The hemodynamic response consistently provides an excess of oxygen over what is required, and this results in some oxyhemoglobin traveling through the capillary bed and local venous structure without being converted into deoxyhemoglobin. Oxy- and deoxyhemoglobin have different magnetic susceptibilities, and different infrared spectra. The hemodynamic response, by changing the net ratio of oxy- to deoxyhemoglobin in the local venous structure, thus changes the local magnetic susceptibility and local infrared resonance spectra around focused brain activity. This complex chain reaction is called the Blood Oxygen Level Dependent, or BOLD effect (Reference 8). The BOLD effect leads to a method to indirectly measure the local brain activity by monitoring the hemodynamic response using Magnetic Resonance Imaging (MRI) or Near Infrared Spectroscopy (NIRS). The BOLD response to any event peaks about 4-6 seconds after the event occurs, limiting the applications for which monitoring these signals and their associated delay may be useful, given the BMI operating parameters defined above Furthermore, person to person variation in distributed signals show significant differences in regions activated (Reference 9), though there is evidence that these inter-subject variations are stable intra-subject over time (Reference 10). Control of External Devices In general, there are two types of BMI design called open-loop and closed-loop. Open loop designs, those either detecting activity or providing stimulation, are important for BMI research and application other than the practical control of an external device. Closed-loop systems include both output signals from the brain to effect a change in the state of a device, and a stimulation channel, which can be used as feedback. In some system designs, the feedback can be via visual cues such as watching a display (Reference 11). Open-loop systems are important for BMI research and have application in sense replacement such as artificial hearing, or when extensive output signal processing is combined with external device state feedback (see remote robot operation below). For learning and fine, efficient control of external devices without significant external processing, closed-loop systems are typically needed. Several components constitute a general BMI system for control of an external device (Figure 2). As mentioned in the previous section, the interfaces where the information signal makes the jump between biological and physical pathways are the most challenging part of the system. These connections can be placed to stimulate or read peripheral or cerebral neurons. The processing step could be as simple as amplification

View the document record ↗ · Physical page 10, counting the cover.

EXCERPT 15 · PHYSICAL PAGE 11

D130, physical page 11: Figure 2, closed-loop control interface, and usefulness of BMIs

UNCLASSIFIED/ /FOR: 8Ffl@IJltt t:191!! er•t I of a spiking train to trigger a switch, or as complex as decoding signal from noise utiliz ing a 300-channel EEG cap. ~-------------------------, : Additional sensory : I ---1 -------------------' ~ Brain Output interface ,----1 Input interface Output signal processing Components of a Closed-loop BMI Control System Input signal processing External Device Figure 2. The General Layout of a Closed-Loop Control Interface. The input and output interfaces can attach to read or affect activity of cerebra l or peripheral neurons . Additional sensory feedback channels such as visual displays, audio tones, or haptic feedback are possible. In some system designs, especially noninvasive types, these sensory feedback channels replace stimulat ion inputs. In an open-loop interface, either the input or output signal paths are absent. One consideration in developing a BMI control system is the utility of the application: does it make sense to directly tie these controls to neural activity? The bulk of research in direct neural interfaces is toward the goal of restoring mechanical capabilities to those individuals who have either lost limbs or lost control of limbs through central nervous system injury or disease. In these cases it is of obvious utility to produce a system that moves a cursor across screen to select an item over the course of several seconds; however, for a healthy individual, it is far more practical to execute a hand movement to control a mechanical device4 to achieve the same goal. An exception to consider is the case of applications where the subject's hands or feet are already occupied with other essential tasks in the overall application. A research question for any such application is whether training a subject to uti lize a BMI is advantageous over a more complex mechanical interface. Furthermore, whether training on a new BMI affects learning/retaining proficiency with similar BMis is an additional concern. Moreover, for any BMI, one can quantitatively describe the informat ion transfer in controlling the magnitude of human motor action (Reference 12). Since the advent of digital control of external devices, this information is expressed in equivalent bits per 4 Mechanical device as used here represents any limb-operated interface, such as a mouse or touchscreen. UNCLASSIFIED/ /FOR OFFI&IAk W&E 8Ptk¥ 5
Check the original PDF
of a spiking train to trigger a switch, or as complex as decoding signal from noise utilizing a 300-channel EEG cap. [Figure 2 labels: Components of a Closed-loop BMI Control System; Additional sensory; Brain; Input interface; Input signal processing; Output interface; Output signal processing; External Device] Figure 2. The General Layout of a Closed-Loop Control Interface. The input and output interfaces can attach to read or affect activity of cerebral or peripheral neurons. Additional sensory feedback channels such as visual displays, audio tones, or haptic feedback are possible. In some system designs, especially noninvasive types, these sensory feedback channels replace stimulation inputs. In an open-loop interface, either the input or output signal paths are absent. One consideration in developing a BMI control system is the utility of the application: does it make sense to directly tie these controls to neural activity? The bulk of research in direct neural interfaces is toward the goal of restoring mechanical capabilities to those individuals who have either lost limbs or lost control of limbs through central nervous system injury or disease. In these cases it is of obvious utility to produce a system that moves a cursor across screen to select an item over the course of several seconds; however, for a healthy individual, it is far more practical to execute a hand movement to control a mechanical device⁴ to achieve the same goal. An exception to consider is the case of applications where the subject's hands or feet are already occupied with other essential tasks in the overall application. A research question for any such application is whether training a subject to utilize a BMI is advantageous over a more complex mechanical interface. Furthermore, whether training on a new BMI affects learning/retaining proficiency with similar BMIs is an additional concern. Moreover, for any BMI, one can quantitatively describe the information transfer in controlling the magnitude of human motor action (Reference 12). Since the advent of digital control of external devices, this information is expressed in equivalent bits per ⁴ Mechanical device as used here represents any limb-operated interface, such as a mouse or touchscreen.

View the document record ↗ · Physical page 11, counting the cover.

EXCERPT 16 · PHYSICAL PAGE 12

D130, physical page 12: information rates, cognitive limits and noninvasive technologies

UNCLASSIFIED/ /POil 8ffl61Al W&li 0NL¥ second transferred. Higher bit rates equate to more efficient interfaces . Baseline examples of performance include finger pointing, which can convey 14 bits/s of informatio n (Reference 13), operation of a mouse about 8 bits/s (Reference 14), while stylus tapping a soft QWERTY keyboard on a PDA has a lower rate, around 5 bits/s (Reference 15). Once these questions are researched and answered for a given application, the design choice should be made whether a new mechanical interface, or an optical interface that tracking detailed motion of the eyes, body and limbs, may be the optimum solution rather than a BMI.5 Another consideration in developing a BMI control system is the cognitive limit of supervisory control of external devices. The current state of the art for human interfaces involves volition of control, meaning that there is some executive supervision, typically involving the pre-frontal cortex, active during the control process. Recent studies relating to control of semiautonomous vehicles show that there are significant limits on the number of supervisory activities that can be undertaken simultaneously (Reference 16). In response to these limits, one can consider utilizatio n of nonsupervised brain networks in control of external devices, similar to those brain systems that initiate very complex muscle coordination activity such as martial arts or playing a musical instrume nt, or systems like those that are responsible for autonomic function. Application from such research is long term, but there are current studies that show BMI training of at least one spinal cord patient exhibited differential activity in the cerebellum, owing to extraordinary plasticity (Reference 17). It is therefore not out of the realm of possibility that sufficient input and output interfaces that include neural pathways through the cerebellum could result in over-learning a BMI application to the point that supervisory control is developed and thus significant cognitive effort is not required. Noninvasive Technologies There are four noninvasive technologies currently in widespread use in monitoring brain activity. The two direct-measure technologies involve detecting surface currents from the relative voltage changes at or just below the scalp, electroencephalography (EEG), and detection of near scalp magnetic fields associated wit h neura l pathway current flow, magnetoencephalography (MEG). The remaining two indirect measures involve monitoring BOLD response through rapid successions of whole brain MRI (functional MRI or fMRI), and near-i nfrared spectroscopy (NIRS). 6 The primary technology used for BMI is also the oldest. EEG was first described in 1929 (Reference 18) and now exists in several derivative forms. Traditional EEG uses electrodes at the surface of the scalp to measure and amplify potential differences between points above the cortical surface and a fixed refere nce such as the average reading from the earlobes. Traditional EEG data is analyzed by breaking up the power spectrum into several bands between 0.5 and 100 Hz. A derivative form of EEG developed about 10 years later is called event-related potentials, or ERP. In ERP, scalp 5 There is a valid argument to be made that optical tracking and analysis, especially of the eyes, is a BMI technology as defined in the current treatise. It is excluded as one merely by fiat. 6 NIRS is occasionally referred to as functional NIRS or fNIRS. NIRS using multiple sources to produce 3D images of internal changes in blood flow is occasionally called diffuse optical tomography (DOT). DOT is a more general technology that can also refer methods such as to visible-light laser excitation of tissue. UNCLASSIFIED/ /FOil OFFl61Al WSE OHlY 6
Check the original PDF
second transferred. Higher bit rates equate to more efficient interfaces. Baseline examples of performance include finger pointing, which can convey 14 bits/s of information (Reference 13), operation of a mouse about 8 bits/s (Reference 14), while stylus tapping a soft QWERTY keyboard on a PDA has a lower rate, around 5 bits/s (Reference 15). Once these questions are researched and answered for a given application, the design choice should be made whether a new mechanical interface, or an optical interface that tracking detailed motion of the eyes, body and limbs, may be the optimum solution rather than a BMI.⁵ Another consideration in developing a BMI control system is the cognitive limit of supervisory control of external devices. The current state of the art for human interfaces involves volition of control, meaning that there is some executive supervision, typically involving the pre-frontal cortex, active during the control process. Recent studies relating to control of semiautonomous vehicles show that there are significant limits on the number of supervisory activities that can be undertaken simultaneously (Reference 16). In response to these limits, one can consider utilization of nonsupervised brain networks in control of external devices, similar to those brain systems that initiate very complex muscle coordination activity such as martial arts or playing a musical instrument, or systems like those that are responsible for autonomic function. Application from such research is long term, but there are current studies that show BMI training of at least one spinal cord patient exhibited differential activity in the cerebellum, owing to extraordinary plasticity (Reference 17). It is therefore not out of the realm of possibility that sufficient input and output interfaces that include neural pathways through the cerebellum could result in over-learning a BMI application to the point that supervisory control is developed and thus significant cognitive effort is not required. Noninvasive Technologies There are four noninvasive technologies currently in widespread use in monitoring brain activity. The two direct-measure technologies involve detecting surface currents from the relative voltage changes at or just below the scalp, electroencephalography (EEG), and detection of near scalp magnetic fields associated with neural pathway current flow, magnetoencephalography (MEG). The remaining two indirect measures involve monitoring BOLD response through rapid successions of whole brain MRI (functional MRI or fMRI), and near-infrared spectroscopy (NIRS).⁶ The primary technology used for BMI is also the oldest. EEG was first described in 1929 (Reference 18) and now exists in several derivative forms. Traditional EEG uses electrodes at the surface of the scalp to measure and amplify potential differences between points above the cortical surface and a fixed reference such as the average reading from the earlobes. Traditional EEG data is analyzed by breaking up the power spectrum into several bands between 0.5 and 100 Hz. A derivative form of EEG developed about 10 years later is called event-related potentials, or ERP. In ERP, scalp ⁵ There is a valid argument to be made that optical tracking and analysis, especially of the eyes, is a BMI technology as defined in the current treatise. It is excluded as one merely by fiat. ⁶ NIRS is occasionally referred to as functional NIRS or fNIRS. NIRS using multiple sources to produce 3D images of internal changes in blood flow is occasionally called diffuse optical tomography (DOT). DOT is a more general technology that can also refer methods such as to visible-light laser excitation of tissue.

View the document record ↗ · Physical page 12, counting the cover.

EXCERPT 17 · PHYSICAL PAGE 13

D130, physical page 13: EEG and commercial dry-electrode sensors

UNCLASSIFIED/ j POI\ OFFICIAL l:ISE 8Ptllf data is averaged over several electrodes time-locked to a stimulus (Reference 19). Both the previous methods record summed electrical activity of nominally 50,000 local neurons, thus large coherent group spiking activity 7 is required to produce appreciable signal. EEG EEG-based BMI systems use pattern recognition among the several electrodes to transmit information. In closed-loop systems, audio or visual feedback is utilized. Training on the system and adaptation by the processing software can increase target detection efficiency, though some recent work shows that systems can be produced that nearly work right out of the box. Blankertz demonstrated a system that required only 20 minutes of training on naNe subjects (Reference 20). Development is partially being driven by the need to provide a means of communication or action on the environment to patients that have lost control of their body. Much of this clinically-orientated research has focused on 'locked-in' patients, who suffer from total paralys is following brainstem stroke or degenerat ive diseases such as amyotrophic lateral sclerosis (ALS) (Reference 21). The goal has been to extract control signals either from surface EEG signals or from electrodes implanted near or within the cerebral cortex: ECoG (see next section on invasive technologies for details on ECoG). ALS deteriorates peripheral motor function before progression to cognitive areas. This greatly reduces a primary source of bioelectric noise, cranial and facial muscle action, and thus provides a reduced signal processing problem to decode neural signals. Successful communication has been established via EEG BMI in several studies based on both spiking activity and P300 signals (References 22-25). The response time to execute a command using these systems is measured in seconds. The results from ALS patients represent a best-case scenario for what could be accomplished using EEG-only sensors in a normal, healthy human who would have significant muscle noise to sift through. The number of electrodes and the time-consuming application of conduct ing gel make EEG arrays bulky and slow to put on. An improvement would be a reduction in the number of electrodes, typically a few dozen for traditional EEG, and electrodes that could operate without conducting gel. Commercial versions of dry-electrode devices are being released on the market from companies such as Neurosky, OCZ Technology, and Emotiv. 8 The Neurosky and Emotive systems claim proprietary processing algor ithms, lack peer-reviewed literature support ing their claims, and even discuss using facial muscle movement to send signals (References 26, 27), raising doubt about whether neural signals are being measured at all. The NIA, for Neural Impulse Actuator, from OCZ clearly states that the electrodes pick up a combination of EEG, EMG, and EOG,9 and that the algorithm is only interpreting the net signal patterns instead of trying to sort out the EEG component. 7 Spiking activity is the term used for recognition of action potentials. Spikes are fast and easy to recognize with electron ic triggering circuits, while more complex waveforms require additional processing . 8 Websites www .emotiv.com , www.ocztechnology .com, and www.neurosky .com, last accessed 12 May 2009. 9 The electrco-myogram (EMG) reads signals from muscle activity, in this case facial muscles. The electro­ oculogram (EOG) measures electrical signals arising from muscles associated with the eyes. 7 UNCLASSIFIED/ fFOR OFFI&I.t.L W&E 8Pttlf
Check the original PDF
data is averaged over several electrodes time-locked to a stimulus (Reference 19). Both the previous methods record summed electrical activity of nominally 50,000 local neurons, thus large coherent group spiking activity⁷ is required to produce appreciable signal. EEG EEG-based BMI systems use pattern recognition among the several electrodes to transmit information. In closed-loop systems, audio or visual feedback is utilized. Training on the system and adaptation by the processing software can increase target detection efficiency, though some recent work shows that systems can be produced that nearly work right out of the box. Blankertz demonstrated a system that required only 20 minutes of training on naïve subjects (Reference 20). Development is partially being driven by the need to provide a means of communication or action on the environment to patients that have lost control of their body. Much of this clinically-orientated research has focused on 'locked-in' patients, who suffer from total paralysis following brainstem stroke or degenerative diseases such as amyotrophic lateral sclerosis (ALS) (Reference 21). The goal has been to extract control signals either from surface EEG signals or from electrodes implanted near or within the cerebral cortex: ECoG (see next section on invasive technologies for details on ECoG). ALS deteriorates peripheral motor function before progression to cognitive areas. This greatly reduces a primary source of bioelectric noise, cranial and facial muscle action, and thus provides a reduced signal processing problem to decode neural signals. Successful communication has been established via EEG BMI in several studies based on both spiking activity and P300 signals (References 22-25). The response time to execute a command using these systems is measured in seconds. The results from ALS patients represent a best-case scenario for what could be accomplished using EEG-only sensors in a normal, healthy human who would have significant muscle noise to sift through. The number of electrodes and the time-consuming application of conducting gel make EEG arrays bulky and slow to put on. An improvement would be a reduction in the number of electrodes, typically a few dozen for traditional EEG, and electrodes that could operate without conducting gel. Commercial versions of dry-electrode devices are being released on the market from companies such as Neurosky, OCZ Technology, and Emotiv.⁸ The Neurosky and Emotive systems claim proprietary processing algorithms, lack peer-reviewed literature supporting their claims, and even discuss using facial muscle movement to send signals (References 26, 27), raising doubt about whether neural signals are being measured at all. The NIA, for Neural Impulse Actuator, from OCZ clearly states that the electrodes pick up a combination of EEG, EMG, and EOG,⁹ and that the algorithm is only interpreting the net signal patterns instead of trying to sort out the EEG component. ⁷ Spiking activity is the term used for recognition of action potentials. Spikes are fast and easy to recognize with electronic triggering circuits, while more complex waveforms require additional processing. ⁸ Websites www.emotiv.com, www.ocztechnology.com, and www.neurosky.com, last accessed 12 May 2009. ⁹ The electrco-myogram (EMG) reads signals from muscle activity, in this case facial muscles. The electro-oculogram (EOG) measures electrical signals arising from muscles associated with the eyes.

View the document record ↗ · Physical page 13, counting the cover.

EXCERPT 18 · PHYSICAL PAGE 14

D130, physical page 14: Figure 3, commercial EEG sensors, and MEG

UNCLASSIFIED/ /FOR OFFI@Il.tk WSI: Ortklf Commercial EEG sensors Mindset, by NeuroSky nia, by OCZ Technology Figure 3. Two Commercially Available EEG Sensors. The Mindset utilizes two sensors, one in the right earphone and one for placement on the forehead (what looks like a microphone arm is to be pressed against the forehead). The nia records signals from three sensors on the forehead . In a documented and peer-reviewed study, Popescu and colleagues have shown a system that uses 6 dry electrodes and is 90 percent accurate in operation of a 1-D cursor by untrained subjects. Additionally, a measurement of error rates as a function of number of electrodes show that an increase to 12 electrodes could drop the error rate to around 5 percent, but that addit ional electrodes much beyond a dozen do not significantly improve the accuracy of their algorithm (Reference 28). MEG MEG-based BMI systems have been shown to be feasible utilizing a subject imagining limb movements for binary decisions (References 29, 30). Future work could improve the methodology to parallel that achieved with EEG; however, there are significant technological hurdles to a field deployment of MEG. The magnetic fields from neural activity are detected with very sensitive devices called superconduct ing quantum interference devices, or SQUIDs. These detectors are sensitive to the neural activity induced 100 fT (femtoTesla) changes near the scalp. SQUIDs only operate at very low temperatu res thus requiring a cryogenic system as well significant detection and amplification electronics. The availability of a cold sink and high vacuum, such as in a space-based application, could reduce the support system overhead, but there is still the matter of the weakness of the signals. Even if future detector development like atomic magnetometers would solve the equipment overhead issue for Earthbound application, the fact that 100 fT is about 100 milli on times smaller than the Earth's magnetic field will prove an insurmountable barrier to sifting signal from noise in anything but a heavily-sh ielded, metal-free environment . Attempts have been made to use High-Tc superconductors as a shielding material with some success (Reference 31), but significant further development is needed. UNCLASSIFIED/ /FOR OFFIEiIAk WSIE 8HL1/ 8
Check the original PDF
[Figure 3 labels: Commercial EEG sensors; MindSet, by NeuroSky; nia, by OCZ Technology] Figure 3. Two Commercially Available EEG Sensors. The Mindset utilizes two sensors, one in the right earphone and one for placement on the forehead (what looks like a microphone arm is to be pressed against the forehead). The nia records signals from three sensors on the forehead. In a documented and peer-reviewed study, Popescu and colleagues have shown a system that uses 6 dry electrodes and is 90 percent accurate in operation of a 1-D cursor by untrained subjects. Additionally, a measurement of error rates as a function of number of electrodes show that an increase to 12 electrodes could drop the error rate to around 5 percent, but that additional electrodes much beyond a dozen do not significantly improve the accuracy of their algorithm (Reference 28). MEG MEG-based BMI systems have been shown to be feasible utilizing a subject imagining limb movements for binary decisions (References 29, 30). Future work could improve the methodology to parallel that achieved with EEG; however, there are significant technological hurdles to a field deployment of MEG. The magnetic fields from neural activity are detected with very sensitive devices called superconducting quantum interference devices, or SQUIDs. These detectors are sensitive to the neural activity induced 100 fT (femtoTesla) changes near the scalp. SQUIDs only operate at very low temperatures thus requiring a cryogenic system as well significant detection and amplification electronics. The availability of a cold sink and high vacuum, such as in a space-based application, could reduce the support system overhead, but there is still the matter of the weakness of the signals. Even if future detector development like atomic magnetometers would solve the equipment overhead issue for Earthbound application, the fact that 100 fT is about 100 million times smaller than the Earth's magnetic field will prove an insurmountable barrier to sifting signal from noise in anything but a heavily-shielded, metal-free environment. Attempts have been made to use High-Tc superconductors as a shielding material with some success (Reference 31), but significant further development is needed.

View the document record ↗ · Physical page 14, counting the cover.

EXCERPT 19 · PHYSICAL PAGE 15

D130, physical page 15: EMG and magnetic resonance imaging

UNCLASSIFIED/ /FOA OFFIEill.tL l::181: 8HLY EMG Instead of measuring nerve impulses and amplifying them, one can design a system that monitors muscle movement in a hands-free approach to a mechanical interface, essentially using the muscles as a biological amplifier of neural signals. One may close the feedback loop using a heads-up display, monocle, or other visual device, or another traditional sensory feedback. The advantage of such a design is that controls may be actuated through a lightweight wireless system, effectively providing control stations anywhere such a wireless system would work. Such a system could be used to untie a pilot from the cockpit. Recent work has shown that performance of 1-2 bits/s is possible with minimal training, about four times the current performance of a comparison EEG forehead sensor (Reference 14). MRI AND FMRI Magnetic Resonance Imaging (MRI) works by a simple excitation and relaxation of spin states. When molecules containing hydrogen are placed in a strong static magnetic field, a small but detectable number of hydrogen protons align their intrinsic spins along the direction of the external field. An applied radiofrequency (RF) pulse near the proton resonant frequency, 42.6 MHz/Tesla or 128 MHz at 3 Tesla, knocks the spins perpend icular to the field and the relaxation back to ground state releases RF energy in patterns that can be reconstructed to show both composition and distr ibution of any hydrogen-rich mater iel. The resonant frequency is a direct funct ion of the local magnetic field defined by the Larmor relation: c.o = y B; where c.o is the frequency of precession, B is the local magnetic field, and y is a constant of the mater ial, 42.6 MHz/Tesla for bare protons as mentioned above. Small perturbations to the static field will change the resonant frequency. By applying a small gradient to the stat ic field, for example 100 milliTes la/meter along the z-axis, and limiting the bandwidth of the RF excitation signal to 8ro, one may select a slice of the brain perpendicular to the z-axis for excitat ion to 82. A change in the gradient field will change the position of the excited slice for the next excitation. Similar gradients in the x and y d irections can limit the excitation to a single small volume of brain tissue. In current MRis, these gradient fields are produced with electromagnets, and the series of time-dependent imaging gradient manipulations is called the scan sequence. Free hydrogen (H) would produce a resonant signal slightly different than the bare proton due to the local field changes induced by its valance electron. Hydrogen gas (H2) would produce a still different frequency since the local field around each proton is altered by the two shared electrons. Water molecules (H2O) contain two hydrogen atoms and an entirely different "electron shield" than either H or H2 and thus shows still another slightly different resonant frequency. Fat and other lipid molecules, important cell structure building blocks, have long chains of hydrocarbons, and the resulting ensemble of electron screening produces a wide peak that is substant ially shifted 10 from that of water. Brain gray matter and white matter have different macroscopic lipid content and are thus able to be differentiated in an MRI scan. Different signals also arise in bone, 1° Frequency detection sensitivities in MRI are very good, and "su bstant ial" here means about 3 parts per million. The frequency shifts caused by imaging gradients ranges in the parts per thousand. UNCLASSIFIED/ f FOA OFFIEiIAL l::ISE 8PtLY 9
Check the original PDF
EMG Instead of measuring nerve impulses and amplifying them, one can design a system that monitors muscle movement in a hands-free approach to a mechanical interface, essentially using the muscles as a biological amplifier of neural signals. One may close the feedback loop using a heads-up display, monocle, or other visual device, or another traditional sensory feedback. The advantage of such a design is that controls may be actuated through a lightweight wireless system, effectively providing control stations anywhere such a wireless system would work. Such a system could be used to untie a pilot from the cockpit. Recent work has shown that performance of 1-2 bits/s is possible with minimal training, about four times the current performance of a comparison EEG forehead sensor (Reference 14). MRI AND FMRI Magnetic Resonance Imaging (MRI) works by a simple excitation and relaxation of spin states. When molecules containing hydrogen are placed in a strong static magnetic field, a small but detectable number of hydrogen protons align their intrinsic spins along the direction of the external field. An applied radiofrequency (RF) pulse near the proton resonant frequency, 42.6 MHz/Tesla or 128 MHz at 3 Tesla, knocks the spins perpendicular to the field and the relaxation back to ground state releases RF energy in patterns that can be reconstructed to show both composition and distribution of any hydrogen-rich materiel. The resonant frequency is a direct function of the local magnetic field defined by the Larmor relation: ω = γ B; where ω is the frequency of precession, B is the local magnetic field, and γ is a constant of the material, 42.6 MHz/Tesla for bare protons as mentioned above. Small perturbations to the static field will change the resonant frequency. By applying a small gradient to the static field, for example 100 milliTesla/meter along the z-axis, and limiting the bandwidth of the RF excitation signal to δω, one may select a slice of the brain perpendicular to the z-axis for excitation to δz. A change in the gradient field will change the position of the excited slice for the next excitation. Similar gradients in the x and y directions can limit the excitation to a single small volume of brain tissue. In current MRIs, these gradient fields are produced with electromagnets, and the series of time-dependent imaging gradient manipulations is called the scan sequence. Free hydrogen (H) would produce a resonant signal slightly different than the bare proton due to the local field changes induced by its valance electron. Hydrogen gas (H2) would produce a still different frequency since the local field around each proton is altered by the two shared electrons. Water molecules (H2O) contain two hydrogen atoms and an entirely different "electron shield" than either H or H2 and thus shows still another slightly different resonant frequency. Fat and other lipid molecules, important cell structure building blocks, have long chains of hydrocarbons, and the resulting ensemble of electron screening produces a wide peak that is substantially shifted¹⁰ from that of water. Brain gray matter and white matter have different macroscopic lipid content and are thus able to be differentiated in an MRI scan. Different signals also arise in bone, ¹⁰ Frequency detection sensitivities in MRI are very good, and "substantial" here means about 3 parts per million. The frequency shifts caused by imaging gradients ranges in the parts per thousand.

View the document record ↗ · Physical page 15, counting the cover.

EXCERPT 20 · PHYSICAL PAGE 16

D130, physical page 16: functional MRI, NIRS and beginning of invasive technologies

UNCLASSIFIED/ /P91t 9Ffl@IAL YSIE 8HLY cerebral-spinal fluid (CSF), and internal tissue structures of various other organs. Unlike x-ray based technologies, MRI scans can be optimized to contrast any of the many parts of the physics signal: total density of protons, water content, lipid content, and even particle motion in advanced techniques involving diffusion or spin labeling. Using such scans sequences that take several minutes, one can construct very high resolution images of gray and white matter structure for comparison with, and also mapping onto a "standard brain" template. In addition to electron screening, macroscopic susceptibility will also change the local response to RF stimulation. The presence of even a small amount of metal, say as small as a hairpin, will greatly distort the reconstructed images. Indeed, the usual effect is a shift of frequency completely outside the sensitivity of the machine RF receiver in what is known as "drop-o ut." Smaller changes in local susceptibility, like produced in the BOLD effect, are measureable. A series of fast scan sequences, typically collecting an entire brain volume at a resolution of 3 mm3 in 2 seconds, that are calibrated to optimize detection of the BOLD signal will show the dynamics of brain function under the specific internal or applied conditions; this is known as a functional MRI, or simply fMRI. 11 The major advantages of fMRI are unmatched 3D spatial resolution, compared to othe r noninvasive imaging methods, and complete skull penetration, making it the only imaging modal ity to unambiguously detect limbic activations important for determining emotionally-laden neuropsychologica l states. The main disadvantage for BMI is that the BOLD signal is detected several seconds after the neuronal firing takes place, making fMRI inappropriate for many naturalistic applications. A long term prospect, likely in the 20- to 40-year timeframe, is that combined low-field MRI and MEG technology could detect neuronal firing deep in the brain and with high temporal accuracy. Initial experiments indicate some level of feasibi lity, but there is substantial development work required in room temperature low field magnetic field detection devices, such as atomic magnetometers, and signal processing algorithms to sift through the substantial electromagnetic background (References 32, 33). NIRS Near-infrared spectroscopy is an additional technology to monitor the BOLD effect noninvasively. Studies have shown it correlates well with the fMRI signal in animal models, although with reduced coverage and lower resolution (Reference 34). This lowered resolution greatly affects the accuracy of the technique, with recent work involving single trials and a decision attaining only 80 percent accuracy (Reference 35). Invasive Technologies The most prolific invasive BMI for use in humans is the cochlear implant (Reference 36), a sensory neuroprosthesis designed to aid in hearing for deaf individuals. This device, under continued development and refinement for more than 30 years, consists of a microphone, sound processor, and a receiver t hat is attached to an array of 11 Specifically this is T2* Echo-Planar Imaging, also called BOLD EPI, Gradient Echo EPI, or BOLD fMRI. This approach is used in well over 95 percent of published functional studies, though there are more advanced techniques that concentrate on smaller portions of the hemodynamic signal. For example, Spin-Echo EPI will provide a higher localization within the gray matter, but the cost is a loss of 90 percent of the signal amplitude. UNCLASSIFIED/ /FOR OFFI&Il.tk WSE 8Hk¥ 10
Check the original PDF
cerebral-spinal fluid (CSF), and internal tissue structures of various other organs. Unlike x-ray based technologies, MRI scans can be optimized to contrast any of the many parts of the physics signal: total density of protons, water content, lipid content, and even particle motion in advanced techniques involving diffusion or spin labeling. Using such scans sequences that take several minutes, one can construct very high resolution images of gray and white matter structure for comparison with, and also mapping onto a "standard brain" template. In addition to electron screening, macroscopic susceptibility will also change the local response to RF stimulation. The presence of even a small amount of metal, say as small as a hairpin, will greatly distort the reconstructed images. Indeed, the usual effect is a shift of frequency completely outside the sensitivity of the machine RF receiver in what is known as "drop-out." Smaller changes in local susceptibility, like produced in the BOLD effect, are measureable. A series of fast scan sequences, typically collecting an entire brain volume at a resolution of 3 mm³ in 2 seconds, that are calibrated to optimize detection of the BOLD signal will show the dynamics of brain function under the specific internal or applied conditions; this is known as a functional MRI, or simply fMRI.¹¹ The major advantages of fMRI are unmatched 3D spatial resolution, compared to other noninvasive imaging methods, and complete skull penetration, making it the only imaging modality to unambiguously detect limbic activations important for determining emotionally-laden neuropsychological states. The main disadvantage for BMI is that the BOLD signal is detected several seconds after the neuronal firing takes place, making fMRI inappropriate for many naturalistic applications. A long term prospect, likely in the 20- to 40-year timeframe, is that combined low-field MRI and MEG technology could detect neuronal firing deep in the brain and with high temporal accuracy. Initial experiments indicate some level of feasibility, but there is substantial development work required in room temperature low field magnetic field detection devices, such as atomic magnetometers, and signal processing algorithms to sift through the substantial electromagnetic background (References 32, 33). NIRS Near-infrared spectroscopy is an additional technology to monitor the BOLD effect noninvasively. Studies have shown it correlates well with the fMRI signal in animal models, although with reduced coverage and lower resolution (Reference 34). This lowered resolution greatly affects the accuracy of the technique, with recent work involving single trials and a decision attaining only 80 percent accuracy (Reference 35). Invasive Technologies The most prolific invasive BMI for use in humans is the cochlear implant (Reference 36), a sensory neuroprosthesis designed to aid in hearing for deaf individuals. This device, under continued development and refinement for more than 30 years, consists of a microphone, sound processor, and a receiver that is attached to an array of ¹¹ Specifically this is T2* Echo-Planar Imaging, also called BOLD EPI, Gradient Echo EPI, or BOLD fMRI. This approach is used in well over 95 percent of published functional studies, though there are more advanced techniques that concentrate on smaller portions of the hemodynamic signal. For example, Spin-Echo EPI will provide a higher localization within the gray matter, but the cost is a loss of 90 percent of the signal amplitude.

View the document record ↗ · Physical page 16, counting the cover.

EXCERPT 21 · PHYSICAL PAGE 17

D130, physical page 17: cochlear implant, direct cortical arrays and penetrating electrodes

UNCLASSIFIED/ /FOR 8FFI€iIAL YSE 8,.LV currently 22 electrodes directly implanted into the cochlea of the inner ear. The microphone and sound processor replaces the outer and middle ear, while the electrodes replace the frequency selective hair fibers of the inner ear that normally would transmit electrical signals to the cochlea. The quality of the sound is much less than natural hearing, but the only option for patients who have lost hearing or were born deaf. It has been estimated that 100,000 cochlear implants provide sound to users worldwide (Reference 37). The cochlear implant is an open loop stimulation system that provides complex signals to the nervous system through a peripheral connection. BMI technologies have evolved from assistive technology devices solely targeted for the healthcare industry, into apparatuses designed for intracortical microstimulation to deliver sensory feedback. Such systems allow the simultaneous recording and microstimulation of neuronal and behavioral events. The primary device that has emerged leading this technological transformation is the direct cortical array containing either surface or neocortex penetrating electrodes. The direct cortical array is implanted on the surface of the brain near the functional area of interest, and then the connection is reverse-engineered: individual electrodes are tested to determine if they should be assigned as input, output, or neither. 12 These devices are designed to fuse neural signaling pathways with external machinery into a 3D control system, such as those apparatuses designed to modulate the movement of appendages (e.g. robotic arms), though the signals could be used for control of any complex machine. The control circuits on these systems are intricate and often bulky, and they can be designed with either open- or closed-loop sensory feedback. An additional device is the penetrating cortical electrode. These electrodes contain a ladder of input/output probes and can be selected to transmit or receive signals in any layer of the neocortex. Research is ongoing regarding the optimal layer with which to place an interface. When using penetrating electrodes, tissue response is an additional challenge as these devices frequently cause scarring. Animal studies are in progress to quantify this effect. Technological challenges in development of all types of invasive BMI devices include signal decoding/stimulation algorithms, and localization of brain activation near the implant. Functional MRI (fMRI) is utilized in conjunction with the invasive implants to confirm additional neural network activity during interface tasks. Modifications in the design of electrodes is necessary for experiments involving fMRI (Reference 38). 13 The majority of invasive experiments to date use animal or even tissue models, though a few human trials have been conducted (with the exception of the cochlear implant described above) . OPEN-LOOP DIRECT CORTICAL ARRAY ALGORITHM MODELING In traditional open loop experiments, eye movement systems are utilized to develop a linear model for a physiological system. 14 In such experiments, invasive signals are recorded from the cortex and the motion of the eye is recorded in tandem. The location t i This procedure eliminates the need to directly locate the neuron(s) of interest during implantation . 13 Field potentials at the points of metal electrodes cause concentration of RF energy from the excitation pulses of the MRI. This effect is used in a similar setup for tissue ablation therapy; however, such energy concentration is undesirable in the studies at hand . 1• These techniques may be generally applied to any motor control systems. UNCLASSIFIED/ /FOR. 8fPltlAL U.91!! f>flt I 11
Check the original PDF
currently 22 electrodes directly implanted into the cochlea of the inner ear. The microphone and sound processor replaces the outer and middle ear, while the electrodes replace the frequency selective hair fibers of the inner ear that normally would transmit electrical signals to the cochlea. The quality of the sound is much less than natural hearing, but the only option for patients who have lost hearing or were born deaf. It has been estimated that 100,000 cochlear implants provide sound to users worldwide (Reference 37). The cochlear implant is an open loop stimulation system that provides complex signals to the nervous system through a peripheral connection. BMI technologies have evolved from assistive technology devices solely targeted for the healthcare industry, into apparatuses designed for intracortical microstimulation to deliver sensory feedback. Such systems allow the simultaneous recording and microstimulation of neuronal and behavioral events. The primary device that has emerged leading this technological transformation is the direct cortical array containing either surface or neocortex penetrating electrodes. The direct cortical array is implanted on the surface of the brain near the functional area of interest, and then the connection is reverse-engineered: individual electrodes are tested to determine if they should be assigned as input, output, or neither.¹² These devices are designed to fuse neural signaling pathways with external machinery into a 3D control system, such as those apparatuses designed to modulate the movement of appendages (e.g. robotic arms), though the signals could be used for control of any complex machine. The control circuits on these systems are intricate and often bulky, and they can be designed with either open- or closed-loop sensory feedback. An additional device is the penetrating cortical electrode. These electrodes contain a ladder of input/output probes and can be selected to transmit or receive signals in any layer of the neocortex. Research is ongoing regarding the optimal layer with which to place an interface. When using penetrating electrodes, tissue response is an additional challenge as these devices frequently cause scarring. Animal studies are in progress to quantify this effect. Technological challenges in development of all types of invasive BMI devices include signal decoding/stimulation algorithms, and localization of brain activation near the implant. Functional MRI (fMRI) is utilized in conjunction with the invasive implants to confirm additional neural network activity during interface tasks. Modifications in the design of electrodes is necessary for experiments involving fMRI (Reference 38).¹³ The majority of invasive experiments to date use animal or even tissue models, though a few human trials have been conducted (with the exception of the cochlear implant described above). OPEN-LOOP DIRECT CORTICAL ARRAY ALGORITHM MODELING In traditional open loop experiments, eye movement systems are utilized to develop a linear model for a physiological system.¹⁴ In such experiments, invasive signals are recorded from the cortex and the motion of the eye is recorded in tandem. The location ¹² This procedure eliminates the need to directly locate the neuron(s) of interest during implantation. ¹³ Field potentials at the points of metal electrodes cause concentration of RF energy from the excitation pulses of the MRI. This effect is used in a similar setup for tissue ablation therapy; however, such energy concentration is undesirable in the studies at hand. ¹⁴ These techniques may be generally applied to any motor control systems.

View the document record ↗ · Physical page 17, counting the cover.

EXCERPT 22 · PHYSICAL PAGE 18

D130, physical page 18: fine motor control models and primate experiments

UNCLASSIFIED/ /P91t 9Ffl@IAL YSIE 8HLY on the cortex to implant cortical arrays is determined from previous experiments in fMRI (References 39, 40). In this way, a map is constructed correlating electrical neural activity with muscle movement. The goal of this exercise is to develop an algorithm that will predict which muscles move based on reading the neural activity alone. The reading of the neural activity for eye movement can then be used to move a device such as a camera lens. There are two main models of fine motor control, one where the cortical motor areas perform all of the control functions and receive all sensory feedback, and a second where the cortical areas direct the function and receive interpreted feedback through sub-cortical or even peripheral networks. For open-loop invasive BMI applications, this is an academic question since peripheral interfaces would receive and send the same signals in both models, and cortical interfaces would blindly adapt external decoding algorithms based on the signals present regardless of model. There have been numerous demonstrations of nonhuman primates controlling robots or graphical cursors in real-time through signals collected from cortical areas that employ open loop experimentation (References 41, 42). Kim, et al. conducted experiments where monkeys are trained on tasks prior to implantation, and then the tasks are repeated multiple times while muscle action and cortical activity are monitored (Reference 42). In these trials, shoulder and elbow torque were measured while the arm itself was constrained in an exoskeleton such that the hand would only move in a plane axial to the monkey's torso. A visual cursor was introduced and projected on a screen above the monkeys hand to follow the 2-D motion from the center starting point to the various task targets, which are also projected on the screen. The shoulder and elbow position recorded the state of flexation of 6 sets of muscle groups, collectively called the musculoskeletal arm model (MAM). Relating the spiking activity from implanted arrays to even this simplified 2-D MAM motion proved quite complex, and no fit correlating the observed movements and neural activity could be obtained with a linear model when kinematic impedance was considered. 15 Even considering the six inputs, the 2-D problem is essentially a computer cursor control and therefore a relatively simple device, fully specified by a Cartesian coordinate system. The ultimate goal of these control systems is to manipulate something much more complex, like an arm, which may have many more degrees of freedom organized in a completely different coordinate system. For these tests a more elaborate "tracking system" may be utilized in teaching a primate to feed itself 16 using a directly observed cortically controlled robotic arm. Open-loop control systems have an inherent drawback in cases where cortical activity controls movement directly via an adaptive algorithm. Training the algorithm is the critical part of interface development. The adaptive algorithms use an iterative process to create a brain-to-cursor motion decoding scheme based on how the neurons fire when different targets are presented and therefore rely on previous normal feedback training - the brain knows how to move an arm because it has been moving an arm for most of its life. 15 Impedance to motion is essential for realistic operation of artificial limbs . 16 Food in this experiment is used as a reward. UNCLASSIFIED/ /F8R 8FFI&I.t.k Y&liii 8,.kY 12
Check the original PDF
on the cortex to implant cortical arrays is determined from previous experiments in fMRI (References 39, 40). In this way, a map is constructed correlating electrical neural activity with muscle movement. The goal of this exercise is to develop an algorithm that will predict which muscles move based on reading the neural activity alone. The reading of the neural activity for eye movement can then be used to move a device such as a camera lens. There are two main models of fine motor control, one where the cortical motor areas perform all of the control functions and receive all sensory feedback, and a second where the cortical areas direct the function and receive interpreted feedback through sub-cortical or even peripheral networks. For open-loop invasive BMI applications, this is an academic question since peripheral interfaces would receive and send the same signals in both models, and cortical interfaces would blindly adapt external decoding algorithms based on the signals present regardless of model. There have been numerous demonstrations of nonhuman primates controlling robots or graphical cursors in real-time through signals collected from cortical areas that employ open loop experimentation (References 41, 42). Kim, et al. conducted experiments where monkeys are trained on tasks prior to implantation, and then the tasks are repeated multiple times while muscle action and cortical activity are monitored (Reference 42). In these trials, shoulder and elbow torque were measured while the arm itself was constrained in an exoskeleton such that the hand would only move in a plane axial to the monkey's torso. A visual cursor was introduced and projected on a screen above the monkeys hand to follow the 2-D motion from the center starting point to the various task targets, which are also projected on the screen. The shoulder and elbow position recorded the state of flexation of 6 sets of muscle groups, collectively called the musculoskeletal arm model (MAM). Relating the spiking activity from implanted arrays to even this simplified 2-D MAM motion proved quite complex, and no fit correlating the observed movements and neural activity could be obtained with a linear model when kinematic impedance was considered.¹⁵ Even considering the six inputs, the 2-D problem is essentially a computer cursor control and therefore a relatively simple device, fully specified by a Cartesian coordinate system. The ultimate goal of these control systems is to manipulate something much more complex, like an arm, which may have many more degrees of freedom organized in a completely different coordinate system. For these tests a more elaborate "tracking system" may be utilized in teaching a primate to feed itself¹⁶ using a directly observed cortically controlled robotic arm. Open-loop control systems have an inherent drawback in cases where cortical activity controls movement directly via an adaptive algorithm. Training the algorithm is the critical part of interface development. The adaptive algorithms use an iterative process to create a brain-to-cursor motion decoding scheme based on how the neurons fire when different targets are presented and therefore rely on previous normal feedback training - the brain knows how to move an arm because it has been moving an arm for most of its life. ¹⁵ Impedance to motion is essential for realistic operation of artificial limbs. ¹⁶ Food in this experiment is used as a reward.

View the document record ↗ · Physical page 18, counting the cover.

EXCERPT 23 · PHYSICAL PAGE 19

D130, physical page 19: limits of the open-loop model, closed-loop peripheral arrays and Figure 4

UNCLASSIFIED/ /FOR OFFI@Il.tk WSI: Ortklf An issue develops when an entirely new device is considered. The form of the movement control algorithm is similar to a population vector in that movement at each time step is determined by a vector sum of the neurons' normal ized firing rates multiplied by a set of linear coefficients. Modern neuroscience has proven that tens of thousands, even up to millions of neurons fire in concert to perform even the most mundane of movements. These extended neural pathways developed through full­ duplex closed loop training. It will thus be quite an issue in an open-loop design to develop an algorithm that can decode control signals for a system the brain has never controlled before, say a 12-direction rocket stabilization system. 17 This places another limitation on the open-loop model, even using complex nonlinear fitting, and has driven development of the closed-loop model. CLOSED-LOOP PERIPHERAL ARRAYS UTILIZING VISUAL FEEDBACK In a closed- loop system that provides feedback to a control system, the differences between the two models of movement become apparent. Sensory feedback within the system is used for error correction of fine motor control, such as balance - without fine motor control and error correction for balance, the human body could not stand up. In the model with abstract cortical control, feedback corrections are processed externally to the BMI and sensory feedback to the brain is usually limited to observation. This is a subtle distinction between open-loop with visual feedback and closed-loop abstract control that includes visual feedback. In the former, the visual feedback is intended to show success of a control command being sent by the brain, whereas in the latter, visual feedback is showing success of supervisory function of a semiautonomous mechanical device. eural Recording JAPAN Figure 4. Experimental Overview of Brain-Controlled Robot in a Closed-Loop With Visual Feedback Experiment. After decoding walking-related Information from a monkey's brain activ ity while walking on a treadmill, these data were relayed from Duke University in USA to the Advanced Telecommunication Research in 17 Twelve directions are the minimum number of positive controls commands to +/- x, y, and z thrust, as well as increasi ng or decreasing roll, pitch , and yaw. These are six degrees of freedom but as far as a BMI control system is concerned, increasing x and decreasing x are separate commands to decode. UNCLASSIFIED/ /iiiOlil OiiiiiilCI0ls !lili OPII.¥ 13
Check the original PDF
An issue develops when an entirely new device is considered. The form of the movement control algorithm is similar to a population vector in that movement at each time step is determined by a vector sum of the neurons' normalized firing rates multiplied by a set of linear coefficients. Modern neuroscience has proven that tens of thousands, even up to millions of neurons fire in concert to perform even the most mundane of movements. These extended neural pathways developed through full-duplex closed loop training. It will thus be quite an issue in an open-loop design to develop an algorithm that can decode control signals for a system the brain has never controlled before, say a 12-direction rocket stabilization system.¹⁷ This places another limitation on the open-loop model, even using complex nonlinear fitting, and has driven development of the closed-loop model. CLOSED-LOOP PERIPHERAL ARRAYS UTILIZING VISUAL FEEDBACK In a closed-loop system that provides feedback to a control system, the differences between the two models of movement become apparent. Sensory feedback within the system is used for error correction of fine motor control, such as balance - without fine motor control and error correction for balance, the human body could not stand up. In the model with abstract cortical control, feedback corrections are processed externally to the BMI and sensory feedback to the brain is usually limited to observation. This is a subtle distinction between open-loop with visual feedback and closed-loop abstract control that includes visual feedback. In the former, the visual feedback is intended to show success of a control command being sent by the brain, whereas in the latter, visual feedback is showing success of supervisory function of a semiautonomous mechanical device. [Figure 4 labels: Neural Recording; Network Interface Architecture; Duke University, USA; Multi-level autonomous control; JST; JAPAN] Figure 4. Experimental Overview of Brain-Controlled Robot in a Closed-Loop With Visual Feedback Experiment. After decoding walking-related information from a monkey's brain activity while walking on a treadmill, these data were relayed from Duke University in USA to the Advanced Telecommunication Research in ¹⁷ Twelve directions are the minimum number of positive controls commands to +/- x, y, and z thrust, as well as increasing or decreasing roll, pitch, and yaw. These are six degrees of freedom but as far as a BMI control system is concerned, increasing x and decreasing x are separate commands to decode.

View the document record ↗ · Physical page 19, counting the cover.

EXCERPT 24 · PHYSICAL PAGE 20

D130, physical page 20: CB-i robot and MEMS, ECoG and PSoC circuits

UNCLASSIFIED/ /P91t 9FFl@IAL YSIE 8HLY Japan in real time. Using visual feedback to the monkey via live stream ing video, the humanoid robot in Japan was shown to execute locomot ion-lik e movements in a similar manner as the monkey . (Reference 43) An example of a closed loop peripheral system is the creation of the humanoid robot called CB-i (Computational Brain Interface) . This system is illustrated in Figure 4. In a recent experiment, CB-i successfully mimicked the physical actions being performed by a monkey that was positioned in a remote location (Reference 43). MEMS , ECOG, AND PSOC CIRCUITRY To address the issue of signal interface between the biological and physical systems, development has focused on hybrid devices that are created by fusing together biomolecules, cells, and other tissues, with innovative micro -size current sensors using Micro Electro Mechanical Systems (MEMS). These systems often employ the use of biomaterials and functional high polymer materials that enable the device to sense information about the human body and the environment with greater speed and sensitivity than conventional metallic sensors. These devices are built from materials and mechanisms that are compatible with the human body, and they are proving to be powerful tools for interfacing between the human body and machines. The emergence of MEMS biotechnology has motivated various strategies to detect electrical signals generated from a stimulated region within the brain into a captured electrical response that is translated to a machine interface. One advantage of these devices is that the fusing of biological to physical circuitry is performed external to the body and the interface connection of the implants is thus biological to biological. This avoids a natural reaction of the nervous system to form scar tissue around penetrating chronic physical probes. 18 Scar tissue leads to degradation of proximal signal transfer over time. These neural -tissue encapsulated chips offer significant advantages over other technologies because of their ability to be rapidly integrated into the biological environment. Noninvasive EEG platforms often utilize a cap that covers the skull and reads the electrical signals generated from the brain on the surface of the skin atop the head. However, a technical limitation in the bandwidth of EEG-based methods often provides low information rates. Currently EEG methods are limited to 20-30 bits/min ( < 0.5 bits/s). This drawback has prompted the use of a more accurate and speedy recording method based on invasive techniques such as the electrocorticogram (ECoG), where electrode arrays are placed on top of the cortex, but electrode penetration into brain tissue is minimal. ECoGs have become synonymous with the pre-surgical monitoring of epileptic seizure foci (Reference 45). Valuable insights can be gained by combining both invasive and noninvasive schemes. For example, combining functional MRI (fMRI) and intracortical recording has yielded important information about metabolic mechanisms that are most highly correlated with recorded neural activity. Microelectric neurochip developments seek to combine signal sensing and processing for bidirectional BMI systems. Studies in the feasibility of using adapt ive input-output models for reconstructing hand trajectories have recently been published. These studies have focused on the 18 Chronic devices are inte nded for long-duration implant, in contrast with acute implanted devices, which are utilized for a short duration and then removed . Formation of scar tissue is dependent on the mater ial used for the electrodes . UNCLASSIFIED/ /FOA OFFI&IAk YSIE 8HL'I 14
Check the original PDF
Japan in real time. Using visual feedback to the monkey via live streaming video, the humanoid robot in Japan was shown to execute locomotion-like movements in a similar manner as the monkey. (Reference 43) An example of a closed loop peripheral system is the creation of the humanoid robot called CB-i (Computational Brain Interface). This system is illustrated in Figure 4. In a recent experiment, CB-i successfully mimicked the physical actions being performed by a monkey that was positioned in a remote location (Reference 43). MEMS, ECOG, AND PSOC CIRCUITRY To address the issue of signal interface between the biological and physical systems, development has focused on hybrid devices that are created by fusing together biomolecules, cells, and other tissues, with innovative micro-size current sensors using Micro Electro Mechanical Systems (MEMS). These systems often employ the use of biomaterials and functional high polymer materials that enable the device to sense information about the human body and the environment with greater speed and sensitivity than conventional metallic sensors. These devices are built from materials and mechanisms that are compatible with the human body, and they are proving to be powerful tools for interfacing between the human body and machines. The emergence of MEMS biotechnology has motivated various strategies to detect electrical signals generated from a stimulated region within the brain into a captured electrical response that is translated to a machine interface. One advantage of these devices is that the fusing of biological to physical circuitry is performed external to the body and the interface connection of the implants is thus biological to biological. This avoids a natural reaction of the nervous system to form scar tissue around penetrating chronic physical probes.¹⁸ Scar tissue leads to degradation of proximal signal transfer over time. These neural-tissue encapsulated chips offer significant advantages over other technologies because of their ability to be rapidly integrated into the biological environment. Noninvasive EEG platforms often utilize a cap that covers the skull and reads the electrical signals generated from the brain on the surface of the skin atop the head. However, a technical limitation in the bandwidth of EEG-based methods often provides low information rates. Currently EEG methods are limited to 20-30 bits/min ( < 0.5 bits/s). This drawback has prompted the use of a more accurate and speedy recording method based on invasive techniques such as the electrocorticogram (ECoG), where electrode arrays are placed on top of the cortex, but electrode penetration into brain tissue is minimal. ECoGs have become synonymous with the pre-surgical monitoring of epileptic seizure foci (Reference 45). Valuable insights can be gained by combining both invasive and noninvasive schemes. For example, combining functional MRI (fMRI) and intracortical recording has yielded important information about metabolic mechanisms that are most highly correlated with recorded neural activity. Microelectric neurochip developments seek to combine signal sensing and processing for bidirectional BMI systems. Studies in the feasibility of using adaptive input-output models for reconstructing hand trajectories have recently been published. These studies have focused on the ¹⁸ Chronic devices are intended for long-duration implant, in contrast with acute implanted devices, which are utilized for a short duration and then removed. Formation of scar tissue is dependent on the material used for the electrodes.

View the document record ↗ · Physical page 20, counting the cover.

EXCERPT 25 · PHYSICAL PAGE 21

D130, physical page 21: Figure 5, Fetz neurochip

UNCLASSIFIED/ ,SfOR 8FFI€il.t.k Wlili QPIIL¥ microelectric design of chronic neural implants. In 2006, Fetz et al. illustrated an intracranial operated neural implant that could function as neural prosthetic to assist upper limb movement for individuals that suffered from spinal cord injuries. The intriguing part of the Fetz design is its ability to funct ion as an autonomous battery operated device. This is a departure from traditional BMI devices that are cumbersome and difficult to operate. Clearly this is a step forward in the development of microwire electrode design applications (Reference 44). Figure 5 illustrates the schematic flow chart of the Fetz MEMS neurochip, also called a programmable system-on-chip (PSoC) architecture . Programmable System on Chip Architecture (1R module) ( eITM>ry) ( MeITM>ry) t t l Prim ry ( Secondary PSoC PSoC( ) J l ! l o :5"' E~w;;:, r.n lf n M icrowire e lectrodes EMG ecllod s Figure 5. Schematic of the Neurochip Functional Blocks. Parallel PSoC microcontrollers record neural and muscle signals to independent memory modules. Primary PSoC also controls a constant-cur rent stimulator circuit and communicates via IR to a PC or hand-held PDA. (Reference 44) Traditional PSoC designs operate on a high power consumption and short battery life of radiotelemetry systems (Reference 46). In the Fetz study, researchers implanted electronic devices that collected data in unrestrained monkeys. The system operated without the power limiting and cumbersome restraints exhibited by these previous systems . For this design, an onboard spike processing and a stimulator circu it were employed to allow for real-time bidirectional interface with the nervous system. After several modifications, Fetz et al. successfully created a device that was able to simultaneously record electromyogram (EMG) activity and neural activity at the implant. The lithium battery operated power source and electronic data systems were skillfully packaged within a compact percutaneous (inner skin) titanium casing that was attached to a monkey's skull; the entire implant weighed only 56 g. Neural data was acquired from 12 microwire electrodes chronically implanted in the primary motor cortex. Leads run subcutaneously from the head casing to a connector on the monkey's back. Two pairs of stainless-steel wires were inserted percutaneously into the forearm muscles where they were attached to an EMG signal recorder (Reference 44). UNCLASSIFIED/ lf81l OfPltlJlcL U:!I! f>flt I 15
Check the original PDF
microelectric design of chronic neural implants. In 2006, Fetz et al. illustrated an intracranial operated neural implant that could function as neural prosthetic to assist upper limb movement for individuals that suffered from spinal cord injuries. The intriguing part of the Fetz design is its ability to function as an autonomous battery operated device. This is a departure from traditional BMI devices that are cumbersome and difficult to operate. Clearly this is a step forward in the development of microwire electrode design applications (Reference 44). Figure 5 illustrates the schematic flow chart of the Fetz MEMS neurochip, also called a programmable system-on-chip (PSoC) architecture. [Figure 5 labels: Programmable System on Chip Architecture; IR module; Memory; Memory; Primary PSoC; Secondary PSoC; Filter + pre-amp; Stimulator; Filter + pre-amp; Microwire electrodes; EMG electrodes] Figure 5. Schematic of the Neurochip Functional Blocks. Parallel PSoC microcontrollers record neural and muscle signals to independent memory modules. Primary PSoC also controls a constant-current stimulator circuit and communicates via IR to a PC or hand-held PDA. (Reference 44) Traditional PSoC designs operate on a high power consumption and short battery life of radiotelemetry systems (Reference 46). In the Fetz study, researchers implanted electronic devices that collected data in unrestrained monkeys. The system operated without the power limiting and cumbersome restraints exhibited by these previous systems. For this design, an onboard spike processing and a stimulator circuit were employed to allow for real-time bidirectional interface with the nervous system. After several modifications, Fetz et al. successfully created a device that was able to simultaneously record electromyogram (EMG) activity and neural activity at the implant. The lithium battery operated power source and electronic data systems were skillfully packaged within a compact percutaneous (inner skin) titanium casing that was attached to a monkey's skull; the entire implant weighed only 56 g. Neural data was acquired from 12 microwire electrodes chronically implanted in the primary motor cortex. Leads run subcutaneously from the head casing to a connector on the monkey's back. Two pairs of stainless-steel wires were inserted percutaneously into the forearm muscles where they were attached to an EMG signal recorder (Reference 44).

View the document record ↗ · Physical page 21, counting the cover.

EXCERPT 26 · PHYSICAL PAGE 22

D130, physical page 22: chronic neural implants and fMRI, Figure 6

UNCLASSIFIED/ /FOR: orr1e1J1tt Y!H: e .. tv CHRONIC NEURAL IMPLANTS AND FMRI While developing microelectric neural chips for functional studies appears revolutionary on the surface, it only presents a piece to the greater puzzle of understanding the feasibility between neuroprosthetic chips and BMI development. For a BMI system to succeed, researchers must understand the brain, its regions of activity and how those area correlate to real time stimulation and neural responses, and how the brain may evolve with training on use of the BMI. This will require the employment of sensitive neural mapping devices such as fMRI. ~ II{ I ! Ill t , i: 0 ..J 04-1.eft Figure 6. Implant Location. Cartoon shows location and orientation of the different electrode sites in the various layers of an animal's neocortical implant (layer thicknesses are approximately scaled). The gray band is the 200µm separation region between the upper and lower layers of the neocortex. To address this question, studies performed by Parikh et al., have targeted tissue­ specific layers within the motor cortex region, essentially a modified ECoG, where penetrating microelectrodes exh ibit the greatest functionality in cortical prosthetic design (Reference 47). The interesting parameter of this experimental design is its ability to successfully employ a behavioral task paradigm where electrodes could accurately record brain activity and animal response based on audible and visual cues. With this information the researchers discovered that the lower layers of the cortex are more likely to encode directional information as compared to units in the upper layers. This understanding has prompted the use of prosthetic neural implants as critical instruments for developing accurate BMI models and the mapping all neurological (brain triggered) responses. For these experiments, accurate measurement of responses was placed solely into the unique design of chronic implantable neural prosthetic devices . These devices enabled investigation of activity in the upper or lower brain tissue layers, including whether either had a preference for ipsilateral (same body side) versus contralateral (opposite side of body) movement. In addition, chronic neural implants prov ided an innovative method to target isolated brain regions. During this experiment a craniotomy was performed over the target cortical area. In this procedure, a 2 mm diameter hole is made into the skull to expose the dura mater. This dura matter is then removed to reveal the cort ical surface. An electrode scaffold array is inserted by hand with the use of fine PTFE-coated forceps into the target cortical area. Typically, the electrode will be UNCLASSIFIED/ /F8R 8FFl@IJltL Y!H! 8,.L'I 16
Check the original PDF
CHRONIC NEURAL IMPLANTS AND FMRI While developing microelectric neural chips for functional studies appears revolutionary on the surface, it only presents a piece to the greater puzzle of understanding the feasibility between neuroprosthetic chips and BMI development. For a BMI system to succeed, researchers must understand the brain, its regions of activity and how those area correlate to real time stimulation and neural responses, and how the brain may evolve with training on use of the BMI. This will require the employment of sensitive neural mapping devices such as fMRI. [Figure 6 labels: Upper (layers I, II, III); separation boundary; Lower (layers V, VI); electrode sites 1 to 16; Reference; D2-Left; D2-Right; D3-Left; D3-Right; D1-Left; D4-Right; D4-Left] Figure 6. Implant Location. Cartoon shows location and orientation of the different electrode sites in the various layers of an animal's neocortical implant (layer thicknesses are approximately scaled). The gray band is the 200µm separation region between the upper and lower layers of the neocortex. To address this question, studies performed by Parikh et al., have targeted tissue-specific layers within the motor cortex region, essentially a modified ECoG, where penetrating microelectrodes exhibit the greatest functionality in cortical prosthetic design (Reference 47). The interesting parameter of this experimental design is its ability to successfully employ a behavioral task paradigm where electrodes could accurately record brain activity and animal response based on audible and visual cues. With this information the researchers discovered that the lower layers of the cortex are more likely to encode directional information as compared to units in the upper layers. This understanding has prompted the use of prosthetic neural implants as critical instruments for developing accurate BMI models and the mapping all neurological (brain triggered) responses. For these experiments, accurate measurement of responses was placed solely into the unique design of chronic implantable neural prosthetic devices. These devices enabled investigation of activity in the upper or lower brain tissue layers, including whether either had a preference for ipsilateral (same body side) versus contralateral (opposite side of body) movement. In addition, chronic neural implants provided an innovative method to target isolated brain regions. During this experiment a craniotomy was performed over the target cortical area. In this procedure, a 2 mm diameter hole is made into the skull to expose the dura mater. This dura matter is then removed to reveal the cortical surface. An electrode scaffold array is inserted by hand with the use of fine PTFE-coated forceps into the target cortical area. Typically, the electrode will be

View the document record ↗ · Physical page 22, counting the cover.

EXCERPT 27 · PHYSICAL PAGE 23

D130, physical page 23: electrode location and Figure 7, histology

UNCLASSIFIED/ ,'FOR: 8Ffl@IJltt t:191!! er•t I localized in a manner where the top site will be below t he cortical surface. The electrode assembly was then wrapped with Gel Foam (Pfizer, I nc. , New York) and then cemented with dental acrylic (Reference 47). Once the experiment was concluded, precise locat ion of the cortical arrays was obtained by passing currents t hough the electrodes to cause micro -lesioning, the n post-mortem examination of brain slices could locate the lesions and reconstruct the precise 3-D position of the electrodes (Figure 7). This test provided an init ial understa nding of brain activity and the ability to utilize microelectrodes to localize specific neural regions. Sample slices from all implants IOOOl)m Multipl sllces from 04 Left Figure 7. Histology and Electrode Tracks. The left panel shows Nissl-stained coronal sections of sample slices from all animals D1-D4 showing electrode tracks or lesion marks for all seven implantations. The black line marks the boundary between the upper and lower layers. The right panel shows seven coronal sections arranged rostro­ caudally, as indicated by the schematic, for one implant (D4Leh) showing alternating lesions and electrode tracks which were used to reconstruct site locations . (Reference 47) UNCLASSIFIED/ /EAR AfifilCl.\k Wlilii o .. tv 17
Check the original PDF
localized in a manner where the top site will be below the cortical surface. The electrode assembly was then wrapped with Gel Foam (Pfizer, Inc., New York) and then cemented with dental acrylic (Reference 47). Once the experiment was concluded, precise location of the cortical arrays was obtained by passing currents though the electrodes to cause micro-lesioning, then post-mortem examination of brain slices could locate the lesions and reconstruct the precise 3-D position of the electrodes (Figure 7). This test provided an initial understanding of brain activity and the ability to utilize microelectrodes to localize specific neural regions. [Figure 7 labels: Sample slices from all implants; D1 Left; D2 Left; D2 Right; D3 Left; D3 Right; D4 Left; D4 Right; Electrode 8; Electrode 5; Electrode 7; 1000µm; 0; 200µm; 300µm; 550µm; 850µm; 900µm; 1000µm; Multiple slices from D4 Left] Figure 7. Histology and Electrode Tracks. The left panel shows Nissl-stained coronal sections of sample slices from all animals D1-D4 showing electrode tracks or lesion marks for all seven implantations. The black line marks the boundary between the upper and lower layers. The right panel shows seven coronal sections arranged rostro- caudally, as indicated by the schematic, for one implant (D4Left) showing alternating lesions and electrode tracks which were used to reconstruct site locations. (Reference 47)

View the document record ↗ · Physical page 23, counting the cover.

EXCERPT 28 · PHYSICAL PAGE 24

D130, physical page 24: new electrode designs and Figure 8

UNCLASSIFIED/ /P91t 9ffl@IAL YSE &P•tlf NEW ELECTRODE DESIGNS Building upon studies like Parikh et al., designs look toward invasive systems capable of pinpointing cortical regions and monitoring their neural activity at or near single neuron resolution. Clement et al. employed microwire neural implants to combine fMRI and intracortical recordings to yield important information about metabolic mechanisms that correlate with neural activity. While modeling studies have been conducted in numerous experiments, they served as a baseline to understand the potential dangers associated with the strong static magnetic field alone or while exposed to typical MRI protocols on the surrounding tissue and the design of an MRI compatible electrical array (References 48, 49). On the surface this may seem a trivial task, however the study shows this is not only a challenging design detail, but decisive in the resulting recorded data of neural activity. Examples of the electrode designs are shown in Figure 8. Figure 8. The Michigan Electrodes. Left: A variety of diffe rent silicon probes have been placed on the back of a U.S. penny . The copper scaffold in the background is the array of columns on the Lincoln Memorial. Right : Four 64- site probes have been assembled into a three -dime nsional structure. (Reference 49) Previous work addressed important issues related to short-term compatibility of silicon microelectrodes. In that report, identification and replacement of appropriate components of a silicon microelectrode system resulted in virtually artifact-free MR images and stable recordings of motor unit activity, although chronic studies were not performed (Reference 50). By utilizing this knowledge the authors designed a microwire electrode array capable of surviving the strong magnetic fluctuations exhibited from an fMRI. Figure 9 shows the device and its related connective components (Reference 51). Figure 10 shows the before and after MR images when connectors and structural screws compatible with MR are employed as well as the compatible electrodes. UNCLASSIFIED/ /f91t 9ffl@IAL Y§E 8Htlf 18
Check the original PDF
NEW ELECTRODE DESIGNS Building upon studies like Parikh et al., designs look toward invasive systems capable of pinpointing cortical regions and monitoring their neural activity at or near single neuron resolution. Clement et al. employed microwire neural implants to combine fMRI and intracortical recordings to yield important information about metabolic mechanisms that correlate with neural activity. While modeling studies have been conducted in numerous experiments, they served as a baseline to understand the potential dangers associated with the strong static magnetic field alone or while exposed to typical MRI protocols on the surrounding tissue and the design of an MRI compatible electrical array (References 48, 49). On the surface this may seem a trivial task, however the study shows this is not only a challenging design detail, but decisive in the resulting recorded data of neural activity. Examples of the electrode designs are shown in Figure 8. Figure 8. The Michigan Electrodes. Left: A variety of different silicon probes have been placed on the back of a U.S. penny. The copper scaffold in the background is the array of columns on the Lincoln Memorial. Right: Four 64-site probes have been assembled into a three-dimensional structure. (Reference 49) Previous work addressed important issues related to short-term compatibility of silicon microelectrodes. In that report, identification and replacement of appropriate components of a silicon microelectrode system resulted in virtually artifact-free MR images and stable recordings of motor unit activity, although chronic studies were not performed (Reference 50). By utilizing this knowledge the authors designed a microwire electrode array capable of surviving the strong magnetic fluctuations exhibited from an fMRI. Figure 9 shows the device and its related connective components (Reference 51). Figure 10 shows the before and after MR images when connectors and structural screws compatible with MR are employed as well as the compatible electrodes.

View the document record ↗ · Physical page 24, counting the cover.

EXCERPT 29 · PHYSICAL PAGE 25

D130, physical page 25: Figures 9 and 10, MRI-compatible electrodes and T2 variability

UNCLASSIFIED/ /FOR OFFI@Il.tk WSI: Ortklf Figure 9. Image Distortion and Custom Microwire Electrode Assembly to Improve It. (A) Image distortion induced by metallic bone screws and connectors . No feature can be identified. Spin echo sequence : TR=ls, TE=6.75ms, NT=4, Matrix=128x128. FOV=60x60mm 2 . Experiment time=512 s. (B) (Top) Microelectrode array used in the study . (Bottom) Close-up of the connector piece that was constructed for multiple connection/disconnection cycles. Interface piece to connect the nano-miniature Omnet ics connector of the head stage with the head-cap-embedded custom connector for extracellular multiun it activity monitoring. (C) Improvement in image quality after replacement of bone screws and connectors with compatible equivalents. TR=3500ms, TE=20ms, averages=2, acquisition matrix=128x96, FOV=21x21mm 2, slice thickness=0.4mm, total acquisition time (TA)=672sec, resolutlon=164µmx220µm . (Reference 51) With this system, the authors successfully recorded sponta neous extracellular multiunit neural activity in 16 electrodes (four in each animal) for 6 weeks post- implant . Of those 16 electrodes, 12 registered data verifying distinct neural activity prior to MR exposure. To determine the overall effectiveness and feasibility of th is procedure, a tissues damage assessment associated with the MRI was conducted by utilizing T2 maps from tissue dissections (Figure 10). Thorough examination of the electrode location and resultant tissue survivability revealed little damage from the operation of the BMI. The locations of the microwires are visible as dark lines in the image (indicated by ovals). $ 009 0011 007 006 005 0 04 003 002 0,01 0 Figure 10. Example of T2 Variability, (A) T2 maps from MRI rat 16 at day 7 post-implant show elevated values proximal to the Implant location (circled). (B) T2 maps from MRI rat 18 at day 30 post-implant shows no difference between the implant and control hemispheres . TR=35 00ms, TE=l0, 20, 30, 40, 50, 60ms, averages=2, acquisition matrix=128x96, FOV=21x21mm 2, slice thickness= 0.4mm, TA=75mins, resolut ion=164µmx220µm. The ovals indicate the site of electrodes . (Reference 51) UNCLASSIFIED/ /fiOlil OfifilCIOP l!SE AN! X 19
Check the original PDF
[Figure 9 labels: (A); (B); (C)] Figure 9. Image Distortion and Custom Microwire Electrode Assembly to Improve It. (A) Image distortion induced by metallic bone screws and connectors. No feature can be identified. Spin echo sequence: TR=1s, TE=6.75ms, NT=4, Matrix=128x128. FOV=60x60mm². Experiment time=512 s. (B) (Top) Microelectrode array used in the study. (Bottom) Close-up of the connector piece that was constructed for multiple connection/disconnection cycles. Interface piece to connect the nano-miniature Omnetics connector of the head stage with the head-cap-embedded custom connector for extracellular multiunit activity monitoring. (C) Improvement in image quality after replacement of bone screws and connectors with compatible equivalents. TR=3500ms, TE=20ms, averages=2, acquisition matrix=128x96, FOV=21x21mm², slice thickness=0.4mm, total acquisition time (TA)=672sec, resolution=164µmx220µm. (Reference 51) With this system, the authors successfully recorded spontaneous extracellular multiunit neural activity in 16 electrodes (four in each animal) for 6 weeks post-implant. Of those 16 electrodes, 12 registered data verifying distinct neural activity prior to MR exposure. To determine the overall effectiveness and feasibility of this procedure, a tissues damage assessment associated with the MRI was conducted by utilizing T2 maps from tissue dissections (Figure 10). Thorough examination of the electrode location and resultant tissue survivability revealed little damage from the operation of the BMI. The locations of the microwires are visible as dark lines in the image (indicated by ovals). [Figure 10 labels: (A); (B); color scale 0 to 0.09] Figure 10. Example of T2 Variability. (A) T2 maps from MRI rat 16 at day 7 post-implant show elevated values proximal to the implant location (circled). (B) T2 maps from MRI rat 18 at day 30 post-implant shows no difference between the implant and control hemispheres. TR=3500ms, TE=10, 20, 30, 40, 50, 60ms, averages=2, acquisition matrix=128x96, FOV=21x21mm², slice thickness= 0.4mm, TA=75mins, resolution=164µmx220µm. The ovals indicate the site of electrodes. (Reference 51)

View the document record ↗ · Physical page 25, counting the cover.

EXCERPT 30 · PHYSICAL PAGE 26

D130, physical page 26: Figure 11, T2 analysis, and hybrid neurorobotic systems

UNCLASSIFIED/ / POI\ OPPlelAL l:l§li &Pn,¥ The results of statistical analysis are shown in Figure 11 comparing the T2 values obtained in the implanted hemisphere versus those in the contralateral (unimplanted) hemisphere. There was no significant difference in T2 values between the two hemispheres. These results prove the feasibility of fMRI neural tracking and the use of microelectrode arrays. With these findings the use of microelectrical implants and fMRI will become a vital instrument in understanding neural activity in invasive BMI. With the growing use of chronic microelectric implants for neurophysiological mapping studies, future studies will be able to explore a new realm of possibilities in BM! applications. Figure 11. T2 Value Analysis Summary of T2 Values in All the Image Slices That Spanned the Electrode Arrays in All Animals. There was no significant difference between the implanted and contralateral control hemispheres in the susceptibility-free regions proximal to electrodes. p-values (one-sided student t-test assuming equal variance): day0 : 0.2, day7 : 0.7, day14 : 0.4, day28 : 0.8, day42: 0.4 . Combining all imaging sessions for all animals : p=0. 60 .-. 50 "' §_ 40 :l 30 ~ .. 20 I- 10 0 0 7 1 28 42 nmePosl-lmplant( Days) HYBRID NEURO-ROBOTIC SYSTEMS FOR TRUE CLOSED-LOOP BMI While many innovations have been seen in BMI technologies that detect neural stimulation from direct cortical regions of monkeys and rats, another approach has been pursued through the use of lamprey eels. Chordates, like the lamprey are ideally suited for neurological studies because of their distinct and readily accessible hollow dorsal nerve cord or brain stem. In the realm of neuroscience the brain stem is often regarded as the most primitive region of the human brain. In one study, Mussa-Ivaldi et al. (References 28, 29) investigated the possibility of using the feedback from a BMI for inducing controlled plastic changes at specific synapses. Figure 12 shows the bidirectional connections between a mobile robotic device and a lamprey brain stem that has been used to investigate the repertoire of operations carried out by neurons in the reticular formation. Signals generated by the two optical sensors of the robot were translated into electrica l stimuli and applied to the vestibular pathways, and to two populations of reticular neurons. The resulting discharge frequency of the reticular neurons commanded the right and left wheels of the robot. In this simple arrangement, the reticular neurons acted as a processing element that determined the closed-loop response of the neuro-robotic system to a source of light. These studies revealed that: • Different behaviors can be generated with different electrode locations. • The input-output relationship of the reticular synapses is well approximated by simple linear models with a recurrent dynamic component. • The prolonged suppression of one input channel leads to altered responsiveness long after it has been restored in the variable frequency pulse generator. The results of this lamprey study hints that cerebellar connections in mamma ls could provide excellent plastic interface points for full closed loop technologies . UNCLASSIFIED/ ,' FOR OFFl@IAL l:l!H! 8HL1/ 20
Check the original PDF
The results of statistical analysis are shown in Figure 11 comparing the T2 values obtained in the implanted hemisphere versus those in the contralateral (unimplanted) hemisphere. There was no significant difference in T2 values between the two hemispheres. These results prove the feasibility of fMRI neural tracking and the use of microelectrode arrays. With these findings the use of microelectrical implants and fMRI will become a vital instrument in understanding neural activity in invasive BMI. With the growing use of chronic microelectric implants for neurophysiological mapping studies, future studies will be able to explore a new realm of possibilities in BMI applications. [Figure 11 labels: Implant; Control; T2 value (ms), 0 to 60; TimePost-Implant(Days), 0, 7, 14, 28, 42] Figure 11. T2 Value Analysis Summary of T2 Values in All the Image Slices That Spanned the Electrode Arrays in All Animals. There was no significant difference between the implanted and contralateral control hemispheres in the susceptibility-free regions proximal to electrodes. p-values (one-sided student t-test assuming equal variance): day0: 0.2, day7: 0.7, day14: 0.4, day28: 0.8, day42: 0.4. Combining all imaging sessions for all animals: p=0. HYBRID NEURO-ROBOTIC SYSTEMS FOR TRUE CLOSED-LOOP BMI While many innovations have been seen in BMI technologies that detect neural stimulation from direct cortical regions of monkeys and rats, another approach has been pursued through the use of lamprey eels. Chordates, like the lamprey are ideally suited for neurological studies because of their distinct and readily accessible hollow dorsal nerve cord or brain stem. In the realm of neuroscience the brain stem is often regarded as the most primitive region of the human brain. In one study, Mussa-Ivaldi et al. (References 28, 29) investigated the possibility of using the feedback from a BMI for inducing controlled plastic changes at specific synapses. Figure 12 shows the bidirectional connections between a mobile robotic device and a lamprey brain stem that has been used to investigate the repertoire of operations carried out by neurons in the reticular formation. Signals generated by the two optical sensors of the robot were translated into electrical stimuli and applied to the vestibular pathways, and to two populations of reticular neurons. The resulting discharge frequency of the reticular neurons commanded the right and left wheels of the robot. In this simple arrangement, the reticular neurons acted as a processing element that determined the closed-loop response of the neuro-robotic system to a source of light. These studies revealed that: • Different behaviors can be generated with different electrode locations. • The input-output relationship of the reticular synapses is well approximated by simple linear models with a recurrent dynamic component. • The prolonged suppression of one input channel leads to altered responsiveness long after it has been restored in the variable frequency pulse generator. The results of this lamprey study hints that cerebellar connections in mammals could provide excellent plastic interface points for full closed loop technologies.

View the document record ↗ · Physical page 26, counting the cover.

EXCERPT 31 · PHYSICAL PAGE 27

D130, physical page 27: Figures 12 and 13, hybrid neurorobotic system and experimental setups

I I , UNCLASSIFIED/ /P91t 9FFl@IAL YSIE 8HLY Lamp1 y bramstem AmplifiersVldoog A c=:;)> Recording ,' I • . , I, I , I Spike de ecttt>n rreq --rt11and low-passpulse fill r ge ' omoor .,_crualC!fs Additional stud ies utiliz ing neurological signals generated from the lamprey have been equally promis ing in eliciti ng cognitive responses that translate a controlled response into a machine's activity. In a similar experiment, Deliagina, and coworke rs (Reference 30) used the act ivity of ret iculospinal neurons recorded from a swimming lamprey to Figure 12. A Hybr id Neuro-Robotic System. Signals from the optical sensors of a Khepera (K-team) mobile robot (bottom) are encoded by the interface into electrical stimulations , the frequency of which depends linearly on the light intensity. These stimuli are delivered by tungsten microelectrodes to the right and left vestibular pathways of a lamprey brainstem (top) that is immersed in artificial cerebrospinal fluid within a recording chamber. The electrical stimuli are delivered to the axons of the intermediate and posterior octavomotor nuclei (nOMI and nOMP, respectively). Glass microelectrodes record extracellular responses to the stimuli from the posterior rhombencepha lic neurons (PRRN). Recorded signals from right and left PRRN are decoded by the interface. First, the electric artifacts generated by the stimulation impulses are removed. Then, population spikes are detected. The resulting spike train is passed through a low-pass filter, which calculates an average firing rate over a 300-millisecond firing window. The average firing rate detected from each electrode is translated into a command to the corresponding wheel of the robot . The angular velocity of the wheel is set to be proportiona l to this average rate. Figure 13. Experimental Arrangements. (A) : arrangement for simultaneo us recordings of neuronal activity, electromyograms (EMGs), and movements in the freely behaving animal. Electrophysiological recordings and the video record ings were synchronized by pulses (1 Hz) recorded simultaneously by both systems (Synchro). (B) : arrangement for recording vestibular responses fn RS neurons during swimming . Centra l, denervated region of the body was fixed in the experimental device. Lamprey could perform locomotor-l ike undulatory movements by its anterior and posterior body parts (indicated by arrows). Device could be rotated manually (a, roll ti lt angle) . UNCLASSIFIED/ /F8R. 8FFI&iIAk Uili QNL¥ Variable ncy rator ___________ 21
Check the original PDF
[Figure 12 labels: nOMI; Lamprey brainstem; nOMP; PRRN; Left; Right; Variable frequency pulse generator; Cancel artifact; Spike detection and low-pass filter; From light sensors; To motor actuators; Khepera mobile robot] Figure 12. A Hybrid Neuro-Robotic System. Signals from the optical sensors of a Khepera (K-team) mobile robot (bottom) are encoded by the interface into electrical stimulations, the frequency of which depends linearly on the light intensity. These stimuli are delivered by tungsten microelectrodes to the right and left vestibular pathways of a lamprey brainstem (top) that is immersed in artificial cerebrospinal fluid within a recording chamber. The electrical stimuli are delivered to the axons of the intermediate and posterior octavomotor nuclei (nOMI and nOMP, respectively). Glass microelectrodes record extracellular responses to the stimuli from the posterior rhombencephalic neurons (PRRN). Recorded signals from right and left PRRN are decoded by the interface. First, the electric artifacts generated by the stimulation impulses are removed. Then, population spikes are detected. The resulting spike train is passed through a low-pass filter, which calculates an average firing rate over a 300-millisecond firing window. The average firing rate detected from each electrode is translated into a command to the corresponding wheel of the robot. The angular velocity of the wheel is set to be proportional to this average rate. [Figure 13 labels: Video; Amplifiers; A; Recording; Synchro; B; α] Figure 13. Experimental Arrangements. (A): arrangement for simultaneous recordings of neuronal activity, electromyograms (EMGs), and movements in the freely behaving animal. Electrophysiological recordings and the video recordings were synchronized by pulses (1 Hz) recorded simultaneously by both systems (Synchro). (B): arrangement for recording vestibular responses in RS neurons during swimming. Central, denervated region of the body was fixed in the experimental device. Lamprey could perform locomotor-like undulatory movements by its anterior and posterior body parts (indicated by arrows). Device could be rotated manually (α, roll tilt angle). Additional studies utilizing neurological signals generated from the lamprey have been equally promising in eliciting cognitive responses that translate a controlled response into a machine's activity. In a similar experiment, Deliagina, and coworkers (Reference 30) used the activity of reticulospinal neurons recorded from a swimming lamprey to

View the document record ↗ · Physical page 27, counting the cover.

EXCERPT 32 · PHYSICAL PAGE 28

D130, physical page 28: human trials and note 19

UNCLASSIFIED/ /POR: err1e1At l:191!! er•t I rotate the platform supporting the fish. The lamprey was able to stabilize the hybrid system, and this compensatory effect was most efficient in combination with undulating swimming motions. The experimental setup is seen in Figure 13. These studies demonstrate the feasibility of closed-loop interactions between a specific region of the nervous system and an artificial device. Closed-loop brain-machine interfaces offer an unparalleled opportunity to investigate how plastic changes can be guided by modulating the input signals of the neurons based on the behaviors generated by the output of the same neurons. Furthermore, in such hybrid systems it is possible to replace the neural tissue with a computational model, thus providing a direct means for testing the predictions of specific hypotheses about neural information processing. Adaptation to the variable dynamics of the limbs and of the limb environment has generated an increasing volume of research that is relevant to brain-machine interfaces. TRIALS USING HUMAN SUBJECTS Testing BMis on normal human subjects presents ethical dilemma since any volunteer outside of the research team itself would likely have difficulty understanding all of the risks involved in neural implantation. Even well-known volunteers such as Jans Naumann now admit they truly did not understand the risks involved and are considering having chronic implants removed. 19 Not all human trials have produced such poor results. Significant ECoG arrays are implanted in epileptic patients prior to surgery to provide high resolution spatial localization of seizure activity (Reference 45). In these clinical tests, the arrays are implanted in the patient and then monitored until seizures takes place. This procedure can take more than a week and the patient has little to do between random onsets of seizure activity. Epilepsy is generally considered a localized pathology, almost always lateralized to the right or left lobe. The remaining brain networks, especially from the nonseizure half of the brain, are generally normal. This provides an opportunity for cohort cognitive studies since they represent minimal additional risk for volunteers undergoing the procedure as a medical necessity. Blakely et al. utilized such a patient to decode brain network patterns associated with different English phonemes (Reference 52). Mapping all of the phonemes could constitute an open-loop technology to communicate without speaking using normal language instead of learned motor patterns. Schalk and colleagues utilized a sample of five pre-surgical epileptics to demonstrate ECoG to control one- and two-dimensional cursor movement. Movement times to target were on the order of 1-2 seconds with up to 75 percent accuracy with training time on the order of 30 minutes or less (Reference 53). Spinal cord injury (SCI) is another clinical condition where the normal brain is intact and ECoG arrays may be implanted for testing a neuroprosthetic. Researchers in Toronto recently reported good hand movement and grasping control using ECoG arrays (Reference 54). Similarly, Hochberg showed good results in 2-D cursor control, but still seconds or more slower than a mouse control, even after 90 days of training. A following task was more successful, though the accuracy for use in fine manipulations needs improvemen t (Reference 55). 19 Jans Naumann was the first recipient of a second-generation artificial vision system (AVS) designed by the Dobelle Institute. The AVS project was based in New York, but the procedures themselves were conducted in Lisbon, Portugal , to avoid U.S. prohibitions against implant surgery. UNCLASSIFIED/ /POR: err1e1At 0!11!! OHLI 22
Check the original PDF
rotate the platform supporting the fish. The lamprey was able to stabilize the hybrid system, and this compensatory effect was most efficient in combination with undulating swimming motions. The experimental setup is seen in Figure 13. These studies demonstrate the feasibility of closed-loop interactions between a specific region of the nervous system and an artificial device. Closed-loop brain-machine interfaces offer an unparalleled opportunity to investigate how plastic changes can be guided by modulating the input signals of the neurons based on the behaviors generated by the output of the same neurons. Furthermore, in such hybrid systems it is possible to replace the neural tissue with a computational model, thus providing a direct means for testing the predictions of specific hypotheses about neural information processing. Adaptation to the variable dynamics of the limbs and of the limb environment has generated an increasing volume of research that is relevant to brain-machine interfaces. TRIALS USING HUMAN SUBJECTS Testing BMIs on normal human subjects presents ethical dilemma since any volunteer outside of the research team itself would likely have difficulty understanding all of the risks involved in neural implantation. Even well-known volunteers such as Jans Naumann now admit they truly did not understand the risks involved and are considering having chronic implants removed.¹⁹ Not all human trials have produced such poor results. Significant ECoG arrays are implanted in epileptic patients prior to surgery to provide high resolution spatial localization of seizure activity (Reference 45). In these clinical tests, the arrays are implanted in the patient and then monitored until seizures takes place. This procedure can take more than a week and the patient has little to do between random onsets of seizure activity. Epilepsy is generally considered a localized pathology, almost always lateralized to the right or left lobe. The remaining brain networks, especially from the nonseizure half of the brain, are generally normal. This provides an opportunity for cohort cognitive studies since they represent minimal additional risk for volunteers undergoing the procedure as a medical necessity. Blakely et al. utilized such a patient to decode brain network patterns associated with different English phonemes (Reference 52). Mapping all of the phonemes could constitute an open-loop technology to communicate without speaking using normal language instead of learned motor patterns. Schalk and colleagues utilized a sample of five pre-surgical epileptics to demonstrate ECoG to control one- and two-dimensional cursor movement. Movement times to target were on the order of 1-2 seconds with up to 75 percent accuracy with training time on the order of 30 minutes or less (Reference 53). Spinal cord injury (SCI) is another clinical condition where the normal brain is intact and ECoG arrays may be implanted for testing a neuroprosthetic. Researchers in Toronto recently reported good hand movement and grasping control using ECoG arrays (Reference 54). Similarly, Hochberg showed good results in 2-D cursor control, but still seconds or more slower than a mouse control, even after 90 days of training. A following task was more successful, though the accuracy for use in fine manipulations needs improvement (Reference 55). ¹⁹ Jans Naumann was the first recipient of a second-generation artificial vision system (AVS) designed by the Dobelle Institute. The AVS project was based in New York, but the procedures themselves were conducted in Lisbon, Portugal, to avoid U.S. prohibitions against implant surgery.

View the document record ↗ · Physical page 28, counting the cover.

EXCERPT 33 · PHYSICAL PAGE 29

D130, physical page 29: EMG interfaces, optical stimulation and beginning of the discussion

UNCLASSIFIED//POlt OPPIEIAL U.!I! 01\LI EMG interfaces for limb amputees have advanced dramatically in the last severa l years, with several devices controlled by remain ing muscles that have been implanted with otherwise unused nerves in an invasive process called reinnervation (References 56, 57). Twelve electrode pairs were util ized in the recording of intended arm motion . The classifier algorithm used to determine hand control was able to provide a new predict ion 10 times a second, and for controls, a motion selection from 1 of 10 possibilities could be achieved in less than 170 milliseconds. Interesting with this procedure is that a direct biological amplification of the neuronal signal is achieved by connecting it to a muscle. The amplified signal is then read by a noninvasive EMG probe. Although not yet approaching normal, the speed and dexterity of these artificial limbs is impressive. Finally, one trial utilizing a normal, healthy human self-experimenter in 2002 showed that sensation and contro l is possible through a peripheral array implant in the median nerve of the left arm. This trial lasted 3 months before the physical connection between the nerve and the microarray dete riorated beyond use. Subsequent exam ination and testing has revealed no long-term damage at the implant site (Reference 58). OPTICAL STIMULATION OF ACTION POTENTIALS A final invasive technology that utilizes light to gate action potentials shows promise (Reference 59). In this technology, the biological switch is controlled by a locally inserted LED and possibly guided using optical fibers, but there is no contact between the physical circu its and neurons, thus avoiding the issue of scar tissue caused by operation of invasive probes. Application to artificial vision have already interesting pre­ clinical results in rat brain tissue (Reference 60). Discussion Any successful BMI hardware technology relies on at least one, and in most cases all, of the follow ing three essential elements: brain plasticity through user training, neural decoding by a machine learning algor ithm, and neuroscience knowledge. Advances in the latter two will help all BMI research paths, but the former element is the most research path dependent since different technologies have different train ing limitations such as the inherent visual feedback delay of a noninvasive BOLD monitor. One approach to the training issue is to greatly simpl ify the control information bandwidth required. Research here has placed a focus on scenario-based controlling that is not from millisecond-to-millisecond updating of some 3-D trajectory like a full­ duplex BMI specified in the introduction would perform, but rather is controlled by high level commands from the user in a low-bandwidth supervisory mode. It is conceivably useful to tell a wheelchair to "Go Left," "Stop," or "Veer Right," and let sensors and actuators on the wheelchair work out the trajectory deta ils, as opposed to constantly setting and resett ing the trajectory of the wheelchair. In this manner, much of the feedback error-correction is done in the physical circuit. This approach can be viewed as a series of simple asynchronous decisions, and relies on the artificial intelligence of the execution algorithms rather than tapping the genera l adaptability of mammalian brain architecture . Mention is made of this research path because it is important to the advancement of the field as a whole, though the concentration in th is treatise is on tapping the plast icity of neural systems rather than creating a program to imitate them . UNCLASSIFIED/ ,'FOR OFFI@IAl WSE OHlY 23
Check the original PDF
EMG interfaces for limb amputees have advanced dramatically in the last several years, with several devices controlled by remaining muscles that have been implanted with otherwise unused nerves in an invasive process called reinnervation (References 56, 57). Twelve electrode pairs were utilized in the recording of intended arm motion. The classifier algorithm used to determine hand control was able to provide a new prediction 10 times a second, and for controls, a motion selection from 1 of 10 possibilities could be achieved in less than 170 milliseconds. Interesting with this procedure is that a direct biological amplification of the neuronal signal is achieved by connecting it to a muscle. The amplified signal is then read by a noninvasive EMG probe. Although not yet approaching normal, the speed and dexterity of these artificial limbs is impressive. Finally, one trial utilizing a normal, healthy human self-experimenter in 2002 showed that sensation and control is possible through a peripheral array implant in the median nerve of the left arm. This trial lasted 3 months before the physical connection between the nerve and the microarray deteriorated beyond use. Subsequent examination and testing has revealed no long-term damage at the implant site (Reference 58). OPTICAL STIMULATION OF ACTION POTENTIALS A final invasive technology that utilizes light to gate action potentials shows promise (Reference 59). In this technology, the biological switch is controlled by a locally inserted LED and possibly guided using optical fibers, but there is no contact between the physical circuits and neurons, thus avoiding the issue of scar tissue caused by operation of invasive probes. Application to artificial vision have already interesting pre-clinical results in rat brain tissue (Reference 60). Discussion Any successful BMI hardware technology relies on at least one, and in most cases all, of the following three essential elements: brain plasticity through user training, neural decoding by a machine learning algorithm, and neuroscience knowledge. Advances in the latter two will help all BMI research paths, but the former element is the most research path dependent since different technologies have different training limitations such as the inherent visual feedback delay of a noninvasive BOLD monitor. One approach to the training issue is to greatly simplify the control information bandwidth required. Research here has placed a focus on scenario-based controlling that is not from millisecond-to-millisecond updating of some 3-D trajectory like a full-duplex BMI specified in the introduction would perform, but rather is controlled by high level commands from the user in a low-bandwidth supervisory mode. It is conceivably useful to tell a wheelchair to "Go Left," "Stop," or "Veer Right," and let sensors and actuators on the wheelchair work out the trajectory details, as opposed to constantly setting and resetting the trajectory of the wheelchair. In this manner, much of the feedback error-correction is done in the physical circuit. This approach can be viewed as a series of simple asynchronous decisions, and relies on the artificial intelligence of the execution algorithms rather than tapping the general adaptability of mammalian brain architecture. Mention is made of this research path because it is important to the advancement of the field as a whole, though the concentration in this treatise is on tapping the plasticity of neural systems rather than creating a program to imitate them.

View the document record ↗ · Physical page 29, counting the cover.

EXCERPT 34 · PHYSICAL PAGE 30

D130, physical page 30: noninvasive electrical devices

UNCLASSIFIED/ /FOR: orr1e1J1tt Y!H: e .. tv The remainder of discussion concentrates on the surveyed studies into five technology areas, and listing their advantages and disadvantages, as well as their critical barriers to further development and likely future paths of research. NONINVASIVE ELECTRICAL DEVICES The current state-of-the-art BMI devices that have shown the most promise in the near term utilize muscle amplification of the neural signal. This is the result of commerc ial investment in development. These primarily EMG based systems are noninvasive connections to existing or constructed nerve-muscle pairs. Neurally operated prosthetics have been demonstrated such as the artificial hand. Decoding algorithms are nearly as fast as muscle response itself at selecting 1 of 10 actions. Commercial products for entertainment are available for normal, healthy consumers. These entertainment devices contain few sensors but make use of more complex decoding algorithms. All sensors don't just turn on and off, rather they can relay amplitude, polarity, and frequency of muscle action, as well as detect underlying spiking signals from neurons. This combination, along with algorithms developed from a support vector machine, will allow device selection of many more actions than the simple binary combinatorics of the number of sensors. The gaming market will drive this noninvasive technology in the next 5 years with advances in signal processing from current sensors. The EMG based systems can be scaled to a large number of sensors for a more complex control task. It has been demonstrated with amputees the feasibility to move existing nerves around to control existing muscles. There has not been a study yet to explore how many nerve-muscle pairs may be available for such use in a normal human, with or without reinnervation. Such a study could be done theoretically based on current and near term work with patients. The longer term for EMG will likely evolve toward very small, wireless chronic implants that operate near the skin surface and are easy to install and remove. Devices based solely on noninvasive detection of EEG signals from the cortex in normal, healthy individuals are unlikely in the next 5 years. This is primarily because of muscle noise filtering issues which will need to be solved through development of better EMG sensors and detection algorithms mentioned above. Even though such devices have been shown to work in laboratory settings, moving them to the arbitrary conditions in naturalistic settings introduces significant complication to signal detection and filtering that greatly limits the information transfer bandwidth to a fraction of the target 5 bits/sec. Also an issue is the origin of surface EEG signals, which are still under theoretical study even after 80 years. Some of the frequency bands direct ly related to spiking activity in axons are somewhat understood, but the whole of the signals contain many transients that are likely the more interesting and possibly more robust parts of brain activity. In the medium to long term, many applications are envisioned in surface or near surface detection of cortical spiking activity or ERP, once the background separation issue in naturalistic environments is addressed . However, these signals still require localized coherent firing of tens of thousands of neurons, a biological requirement that has lim ited the information transfer rates of these techniques to 1 bit/sec or less, which is well below target rates but could be useful for some applications. One can suppose an ultra-high density EEG, thousands of sensors with wireless micro probes embedded subcutaneously that track electrical activity and relative location UNCLASSIFIED/ /FOR. 8FFI@IJltL Y9I!! 9Htl" 24
Check the original PDF
The remainder of discussion concentrates on the surveyed studies into five technology areas, and listing their advantages and disadvantages, as well as their critical barriers to further development and likely future paths of research. NONINVASIVE ELECTRICAL DEVICES The current state-of-the-art BMI devices that have shown the most promise in the near term utilize muscle amplification of the neural signal. This is the result of commercial investment in development. These primarily EMG based systems are noninvasive connections to existing or constructed nerve-muscle pairs. Neurally operated prosthetics have been demonstrated such as the artificial hand. Decoding algorithms are nearly as fast as muscle response itself at selecting 1 of 10 actions. Commercial products for entertainment are available for normal, healthy consumers. These entertainment devices contain few sensors but make use of more complex decoding algorithms. All sensors don't just turn on and off, rather they can relay amplitude, polarity, and frequency of muscle action, as well as detect underlying spiking signals from neurons. This combination, along with algorithms developed from a support vector machine, will allow device selection of many more actions than the simple binary combinatorics of the number of sensors. The gaming market will drive this noninvasive technology in the next 5 years with advances in signal processing from current sensors. The EMG based systems can be scaled to a large number of sensors for a more complex control task. It has been demonstrated with amputees the feasibility to move existing nerves around to control existing muscles. There has not been a study yet to explore how many nerve-muscle pairs may be available for such use in a normal human, with or without reinnervation. Such a study could be done theoretically based on current and near term work with patients. The longer term for EMG will likely evolve toward very small, wireless chronic implants that operate near the skin surface and are easy to install and remove. Devices based solely on noninvasive detection of EEG signals from the cortex in normal, healthy individuals are unlikely in the next 5 years. This is primarily because of muscle noise filtering issues which will need to be solved through development of better EMG sensors and detection algorithms mentioned above. Even though such devices have been shown to work in laboratory settings, moving them to the arbitrary conditions in naturalistic settings introduces significant complication to signal detection and filtering that greatly limits the information transfer bandwidth to a fraction of the target 5 bits/sec. Also an issue is the origin of surface EEG signals, which are still under theoretical study even after 80 years. Some of the frequency bands directly related to spiking activity in axons are somewhat understood, but the whole of the signals contain many transients that are likely the more interesting and possibly more robust parts of brain activity. In the medium to long term, many applications are envisioned in surface or near surface detection of cortical spiking activity or ERP, once the background separation issue in naturalistic environments is addressed. However, these signals still require localized coherent firing of tens of thousands of neurons, a biological requirement that has limited the information transfer rates of these techniques to 1 bit/sec or less, which is well below target rates but could be useful for some applications. One can suppose an ultra-high density EEG, thousands of sensors with wireless micro probes embedded subcutaneously that track electrical activity and relative location

View the document record ↗ · Physical page 30, counting the cover.

EXCERPT 35 · PHYSICAL PAGE 31

D130, physical page 31: limits of EEG and BOLD-based noninvasive devices

UNCLASSIFIED/ /POlt err1e1J1tt U.!I! er\tt I based on skin movement using technology similar to the operation of GPS. This system would have the same inherent problem of signal conduction through tissue from all directions. The key indicator of a future advance in EEG technology would be a study showing noninvasive spiking or ERP signal detection from a coherent group of less than 10,000 neurons. Until progress in localization on this order is demonstrated, EEG-only devices will remain low bit rate application technologies. EEG-only sensor control of devices has been pursued with the supposition that signal transmission directly from the motor cortex will outperform conventional mechanical operation because the signal transmission delay between the neocortex and muscles in the extremities will be augmented via a physical circuit. While this is true, the inherent assumption that complex mechanical interface operation can be replaced with a 1 bit/second low-delay control pathway is incorrect for naturalistic environments. The mill ions of channels of two-way communication between the extremities and the brain naturally present will control naturalistic mechanical devices far better, and provides the ability to react to an ever-changing environment. Adding significant computer control and relegating the motor cortex to a supervisory role of low data bandwidth could have benefits and is a possible path to real-world improved reaction time application. Also beneficial to react ion time is the combined EMG EEG devices mentioned above since the pathways between the brain and facial muscles are far shorter than those to the extremities. NONINVASIVE BOLD - BASED DEVICES The detection resolution of hemodynamic responses using fMRI and NIRS type technologies is expected to improve in the near, medium, and far terms. NIRS has been deployed in naturalistic experiments, specifically, automobile driving, and it is reasonable to envis ion such systems becoming small enough to wear in the medium to far term. The limiting issue with BOLD technologies is that the detectable response is delayed several seconds from neuronal firing, greatly limiting the cognitive control applications available to these technologies. Progress in localization to below 0.5 mm 3 in a mobile device could indicate the possibility of high bit transfer rates with the use of state vector machines, albeit with the inherent delay of the physiology. Until the localization and portability issues are addressed in tandem, BOLD-only devices are unlikely to be used for commercial cognitive control interfaces. The vast majority of experiments in fMRI utilize the General Linear Model (GLM) and something akin to a canonical hemodynamic response. There exists significant physiological noise in these data analyses that are traditionally filtered out. The differential results from Independent Component Analysis (ICA) and GLM analysis of the same data sets indicate that there may be additional circulatory response mechanisms with faster onsets than typical BOLD. Future studies indicating that filtering or analysis methods may be ignoring important detectable signals that have inherently faster response times would provide a breakthrough path for hemodynamic response technologies. The current research to monitor on this matter is the technology known as Inverse MRI which can capture high temporal resolution (100 frames a second for single slices) T2* variations. UNCLASSIFIED/ /POil Offl@IAL YSIE 8Htlf 25
Check the original PDF
based on skin movement using technology similar to the operation of GPS. This system would have the same inherent problem of signal conduction through tissue from all directions. The key indicator of a future advance in EEG technology would be a study showing noninvasive spiking or ERP signal detection from a coherent group of less than 10,000 neurons. Until progress in localization on this order is demonstrated, EEG-only devices will remain low bit rate application technologies. EEG-only sensor control of devices has been pursued with the supposition that signal transmission directly from the motor cortex will outperform conventional mechanical operation because the signal transmission delay between the neocortex and muscles in the extremities will be augmented via a physical circuit. While this is true, the inherent assumption that complex mechanical interface operation can be replaced with a 1 bit/second low-delay control pathway is incorrect for naturalistic environments. The millions of channels of two-way communication between the extremities and the brain naturally present will control naturalistic mechanical devices far better, and provides the ability to react to an ever-changing environment. Adding significant computer control and relegating the motor cortex to a supervisory role of low data bandwidth could have benefits and is a possible path to real-world improved reaction time application. Also beneficial to reaction time is the combined EMG EEG devices mentioned above since the pathways between the brain and facial muscles are far shorter than those to the extremities. NONINVASIVE BOLD- BASED DEVICES The detection resolution of hemodynamic responses using fMRI and NIRS type technologies is expected to improve in the near, medium, and far terms. NIRS has been deployed in naturalistic experiments, specifically, automobile driving, and it is reasonable to envision such systems becoming small enough to wear in the medium to far term. The limiting issue with BOLD technologies is that the detectable response is delayed several seconds from neuronal firing, greatly limiting the cognitive control applications available to these technologies. Progress in localization to below 0.5 mm³ in a mobile device could indicate the possibility of high bit transfer rates with the use of state vector machines, albeit with the inherent delay of the physiology. Until the localization and portability issues are addressed in tandem, BOLD-only devices are unlikely to be used for commercial cognitive control interfaces. The vast majority of experiments in fMRI utilize the General Linear Model (GLM) and something akin to a canonical hemodynamic response. There exists significant physiological noise in these data analyses that are traditionally filtered out. The differential results from Independent Component Analysis (ICA) and GLM analysis of the same data sets indicate that there may be additional circulatory response mechanisms with faster onsets than typical BOLD. Future studies indicating that filtering or analysis methods may be ignoring important detectable signals that have inherently faster response times would provide a breakthrough path for hemodynamic response technologies. The current research to monitor on this matter is the technology known as Inverse MRI which can capture high temporal resolution (100 frames a second for single slices) T2* variations.

View the document record ↗ · Physical page 31, counting the cover.

EXCERPT 36 · PHYSICAL PAGE 32

D130, physical page 32: noninvasive magnetic devices and invasive technologies

UNCLASSIFIED/ fFOlil OFFI&I.t.k WIiii 8Plklf NONINVASIVE MAGNETIC DEVICES Detection of magnetic fields arising from neural activity using MEG or a future technology have the same inherent limitations as EEG-only noninvasive sensors. Resolving these signals from background in any naturalistic environment will not occur without the development of a disruptive technology in shielding that is portable and lightweight enough to be worn comfortably on the head, and will attenuate background amplitude nearly 10 orders of magnitude across the entire range of neural signal frequencies, and the entire range of frequencies where the detection electronics may be sensitive. Body-temperature superconducting materials may accomplish the shielding if engineering development continues, and these could be combined with atomic magnetometer technology to produce a portable system, though the inherent limitations of the method will still be present. INVASIVE TECHNOLOGIES - GENERAL , OPTICAL , AND EX-VIVO ENGINEERING All invasive technologies will have to undergo substantial rigorous testing to determine the long-term side-effects of implantation and operation, as well as drift in the operational performance with extended use. Several pre-clinical devices deta iled above and discussed below show promise, but the handful of human trials show that direct interface technologies based on proximal action potent ial stimulation and detect ion are still a long way off from practical application since the trials themselves in duplex operation show funct ional failure after only a matter of weeks. The mammalian auditory system is well studied, and the cochlear implant has been in use and continued development for more than 30 years, and there is yet to be any practical applicat ion for implanting a cochlear device into a normal healthy individual. Proximal electrode interfaces do not appear to be the answer for high bandwidth BMI, and further development in the machine-biology contact is required. If the 30-year advancement of cochlear is a realistic guide of innovation, the proximal electrical technology path to success is 30-40 years off save for a disruptive advance in the development of penetrating electrodes. Two invasive research paths that are promising are optical stimulation and gating, and ex-vivo growth of neural cells on physical circuits. The advantage of optical stimulation and gating is that one could theoretically design an optical link to act as a connected input dendrite on a single neuron. Theoretically, one should also be able to use spectroscopic sampling to determine if an action potential is progressing down an axon, thus providing a single neuron output (read or monitor) capability as well. This invasive but noncontact full-duplex information channel would effectively hook-up the physical computer seamlessly to the network structure of the brain. Proof of principle studies in this technology could emerge at any time, and given the demonstrated plasticity of neura l networks in both closed-loop visual feedback and lamprey experiments, could provide a disrupt ive path for advancement of BMI. The ex-vivo growth of neural tissue on electrode arrays provides a controlled platform for: • Testing long-term effects of electrode use on proximal neural tissue. UNCLASSIFIED/ /FOlil OFFI€llAL 1:181! 8Htl" 26
Check the original PDF
NONINVASIVE MAGNETIC DEVICES Detection of magnetic fields arising from neural activity using MEG or a future technology have the same inherent limitations as EEG-only noninvasive sensors. Resolving these signals from background in any naturalistic environment will not occur without the development of a disruptive technology in shielding that is portable and lightweight enough to be worn comfortably on the head, and will attenuate background amplitude nearly 10 orders of magnitude across the entire range of neural signal frequencies, and the entire range of frequencies where the detection electronics may be sensitive. Body-temperature superconducting materials may accomplish the shielding if engineering development continues, and these could be combined with atomic magnetometer technology to produce a portable system, though the inherent limitations of the method will still be present. INVASIVE TECHNOLOGIES - GENERAL, OPTICAL, AND EX-VIVO ENGINEERING All invasive technologies will have to undergo substantial rigorous testing to determine the long-term side-effects of implantation and operation, as well as drift in the operational performance with extended use. Several pre-clinical devices detailed above and discussed below show promise, but the handful of human trials show that direct interface technologies based on proximal action potential stimulation and detection are still a long way off from practical application since the trials themselves in duplex operation show functional failure after only a matter of weeks. The mammalian auditory system is well studied, and the cochlear implant has been in use and continued development for more than 30 years, and there is yet to be any practical application for implanting a cochlear device into a normal healthy individual. Proximal electrode interfaces do not appear to be the answer for high bandwidth BMI, and further development in the machine-biology contact is required. If the 30-year advancement of cochlear is a realistic guide of innovation, the proximal electrical technology path to success is 30-40 years off save for a disruptive advance in the development of penetrating electrodes. Two invasive research paths that are promising are optical stimulation and gating, and ex-vivo growth of neural cells on physical circuits. The advantage of optical stimulation and gating is that one could theoretically design an optical link to act as a connected input dendrite on a single neuron. Theoretically, one should also be able to use spectroscopic sampling to determine if an action potential is progressing down an axon, thus providing a single neuron output (read or monitor) capability as well. This invasive but noncontact full-duplex information channel would effectively hook-up the physical computer seamlessly to the network structure of the brain. Proof of principle studies in this technology could emerge at any time, and given the demonstrated plasticity of neural networks in both closed-loop visual feedback and lamprey experiments, could provide a disruptive path for advancement of BMI. The ex-vivo growth of neural tissue on electrode arrays provides a controlled platform for: • Testing long-term effects of electrode use on proximal neural tissue.

View the document record ↗ · Physical page 32, counting the cover.

EXCERPT 37 · PHYSICAL PAGE 34

D130, physical page 34: reference notes (final part of the page)

UNCLASSIFIED/ ,'FOR OFFl&IAk le.ISi: OPtklf directly in the cortex or cerebellum can take the fullest advantage of neural training and processing capability. Two research paths currently showing the most promise are optical interfaces and ex-vivo preparation of electrode arrays encased in engineered neural tissue . New electrode designs that could establish two-way communication with single neurons are also prom ising. The cerebellar connection point is extremely interesting to perhaps provide a connection that would effectively make the external device a part of the body as far as the brain is concerned. The current state of the art using metal electrode arrays for proximal stimulation and sensing does not appear to be advancing toward long duration viability as a commercial BMI without some unforeseen advance in two-way communication. Peripheral connections have some theoretical promise, but an example of such an implant in a human trial did not shown terrific success over several weeks it functioned. Implantation of cortical arrays in human trials has not been conducted on a wide scale for durations longer than a few weeks, and two-way electrical communication has yet to be realistically demonstrated, limiting the possible commercial application portfolio for this technology. Many possible research directions for disruptive advances have been presented. These areas and the physiological-physical interconnection field of study as a whole should be monitored regularly for advances, as well as the ancillary technology areas of brain plasticity, neural signal decoding, and general basic neuroscience. Advances in any and all of these areas could alter the future landscape of commercial applications and dramatically alter our understanding of what is possible through thought-directed control. 1 Alberts B. Molecular biology of the cell. 4th ed. New York : Garland Science; 2002. 2 Polich J. Updating P300: an integrat ive theory of P3a and P3b. Clin Neurophysiol 2007 Oct;118 (10) :2128-48 . 3 Ravden D, Polich J. On P300 measurement stability: habituation, intra-trial block variation, and ultradian rhythms . Biol Psychol 1999 Oct;51(1):59 -76. 4 Sutton S, Braren M, Zubin J, John ER. Evoked-potential correlates of stimulus uncertainty. Science 1965 Nov 26; 150(700): 1187-8. 5 Sawaki R, Katayama J. Top-down directed attention to stimulus features and attentional allocation to bottom -up deviations . J Vis 2008;8(15):4 1-8 . 6 Huettel SA, Song AW, McCarthy G. Functional magnetic resonance imaging. Sunderland, Mass.: Sinauer Associates, Publishers; 2004 . 7 Kandel ER, Schwartz JH, Jessell TM. Principles of neural science. 4th ed. New York : McGraw-Hill, Health Professions Division; 2000. 8 Ogawa 5, Tank DW, Menon R, Ellermann JM, Kim SG , Merkle H, et al. Intrinsic signal changes accompanying sensory stimulation : functional brain mapping with magnetic resonance imaging. Proc Natl Acad Sci US A 1992 Jul 1;89(13) :5951 -5. 9 Emerging Cognit ive Neuroscience and Related Technologies. Washington DC: National Research Council of the National Academies; 2008. 10 Miller MB, Van Horn JD, Wolford GL, Handy TC, Valsangkar-Smyth M, Inati S, et al. Extensive individual differences in brain activations associated with episodic retrieval are reliable over time. J Cogn Neurosci 2002 Nov 15; 14(8): 1200-14. 11 Hatsopoulos NG, Donoghue JP. The Science of Neural Inter face Systems . Annu Rev Neurosci 2009 Mar 24. 12 Fitts PM. The informat ion capacity of the human motor system in controlling the amplitude of movement. J Exp Psychol 1954 Jun;47(6) :381 -91. ' 3 Drury CG, Hoffmann ER. A model for movement time on data -entry keyboards. Ergonomics 1992;35(2):129 - 47 . 14 Choi C, Micera S, Carpanet o J, Kim J. Development and quantitative performance evaluation of a noninvasive EMG computer interface. IEEE Trans Biomed Eng 2009 Jan;56(1):188-91. 15 Soukoreff RW, MacKenzie IS. Theoret ical upper and lower bounds on typing speed using a stylus and soft keyboard. Behaviour & Information Technology 1995;14(6) :370-9. UNCLASSIFIED/ /FOR OFFI@IAL 1:191!!! 9Htl" 28

Editorial note: Bibliographic references kept in their original form (authors, titles and journals), as is standard practice in citations.

Check the original PDF
¹ Alberts B. Molecular biology of the cell. 4th ed. New York: Garland Science; 2002. ² Polich J. Updating P300: an integrative theory of P3a and P3b. Clin Neurophysiol 2007 Oct;118(10):2128-48. ³ Ravden D, Polich J. On P300 measurement stability: habituation, intra-trial block variation, and ultradian rhythms. Biol Psychol 1999 Oct;51(1):59-76. ⁴ Sutton S, Braren M, Zubin J, John ER. Evoked-potential correlates of stimulus uncertainty. Science 1965 Nov 26;150(700):1187-8. ⁵ Sawaki R, Katayama J. Top-down directed attention to stimulus features and attentional allocation to bottom-up deviations. J Vis 2008;8(15):4 1-8. ⁶ Huettel SA, Song AW, McCarthy G. Functional magnetic resonance imaging. Sunderland, Mass.: Sinauer Associates, Publishers; 2004. ⁷ Kandel ER, Schwartz JH, Jessell TM. Principles of neural science. 4th ed. New York: McGraw-Hill, Health Professions Division; 2000. ⁸ Ogawa S, Tank DW, Menon R, Ellermann JM, Kim SG, Merkle H, et al. Intrinsic signal changes accompanying sensory stimulation: functional brain mapping with magnetic resonance imaging. Proc Natl Acad Sci US A 1992 Jul 1;89(13):5951-5. ⁹ Emerging Cognitive Neuroscience and Related Technologies. Washington DC: National Research Council of the National Academies; 2008. ¹⁰ Miller MB, Van Horn JD, Wolford GL, Handy TC, Valsangkar-Smyth M, Inati S, et al. Extensive individual differences in brain activations associated with episodic retrieval are reliable over time. J Cogn Neurosci 2002 Nov 15;14(8):1200-14. ¹¹ Hatsopoulos NG, Donoghue JP. The Science of Neural Interface Systems. Annu Rev Neurosci 2009 Mar 24. ¹² Fitts PM. The information capacity of the human motor system in controlling the amplitude of movement. J Exp Psychol 1954 Jun;47(6):381-91. ¹³ Drury CG, Hoffmann ER. A model for movement time on data-entry keyboards. Ergonomics 1992;35(2):129-47. ¹⁴ Choi C, Micera S, Carpaneto J, Kim J. Development and quantitative performance evaluation of a noninvasive EMG computer interface. IEEE Trans Biomed Eng 2009 Jan;56(1):188-91. ¹⁵ Soukoreff RW, MacKenzie IS. Theoretical upper and lower bounds on typing speed using a stylus and soft keyboard. Behaviour & Information Technology 1995;14(6):370-9.

View the document record ↗ · Physical page 34, counting the cover.

EXCERPT 38 · PHYSICAL PAGE 35

D130, physical page 35: reference notes

UNCLASSIFIED/ /FOA OFFIEIAk Uili 0'11k¥ 16 Cummings ML, Guerlain S. Developing operator capacity estimates for supervisory control of autonomous vehicles . Hum Factors 2007 Feb;49(1):1 -15. 17 Enzinger C, Ropele S, Fazekas F, Loitfelder M, Gorani F, Seifert T, et al. Brain motor system function in a patient with complete spinal cord injury following extensive brain-computer interface training. Exp Brain Res 2008 Sep; 190(2) :215-23. 18 Berger H. Uber das elektrenkephalogramm des menschen . Archiv fur Psychiatrie und Nervenkrankheiten 1929;87(1) :527-80. 19 Davis P. Effects of acoustic stimuli on the waking human brain. Journal of Neurophysiology 1939;2:494-9. 20 Blankertz B, Dornhege G, Krauledat M, Muller KR, Curio G. The non-invasive Berlin Brain-Computer Interfac e: fast acquisition of effective performance in untrained subjects. Neuroimage 2007 Aug 15;37(2):539-50 . 21 Kubler A, Kotchoubey B, Kaiser J, Wolpaw JR, Birbaumer N. Brain-computer communication: unlocking the locked in. Psycho! Bull 2001 May;127(3) :358-75. 22 Bai O, Lin P, Vorbach S, Floeter MK, Hattori N, Hallett M. A high performance sensorimotor beta rhythm -based brain-computer interface associated with human natura l motor behavior. J Neural Eng 2008 Mar;5(1):24 -35. 23 Iversen I, Ghanayim N, Kubler A, Neumann N, Birbaumer N, Kaiser J. Conditional associative learning examined in a paralyzed patient with amyotrophic lateral sclerosis using brain-computer interface technology , Behav Brain Funct 2008;4:53. 24 Iversen IH , Ghanayim N, Kubler A, Neumann N, Birbaumer N, Kaiser J. A brain-computer interface tool to assess cognitive functions in completely paralyzed patients with amyotrophic lateral sclerosis. Clin Neurophysiol 2008 Oct; 119(10):2214-23. 25 Sellers EW, Kubler A, Donchin E. Brain-computer interface research at the University of South Florida Cognitive Psychophysiology Laboratory : the P300 Speller . IEEE Trans Neural Syst Rehabil Eng 2006 Jun; 14(2): 221-4. 26 Greene K. Brain sensor for market research : A startup claims to read people's minds while they view ads. 2007 [May 12, 2009); Available from: http ://www .technologyrev iew.com/Biztech/19833/?a=f . 27 Greene K. Connecting Your Brain to the Game Using an EEG cap, a startup hopes to change the way people interact with video games. 2007 [May 12, 2009]; Available from: http ://www .technoloqyreview .com/Biztech/ 18276 /?a = f. 28 Popescu F, Fazli S, Badower Y, Blankertz B, Muller KR. Single trial classification of motor imagination using 6 dry EEG electrodes. PLoS ONE 2007;2(7) :e637 . 29 van Gerven M, Jensen 0. Attention modulations of posterior alpha as a control signal for two-dimensional brain­ computer interfaces . J Neurosci Methods 2009 Apr 30;179(1) :78-84. 30 Mellinger J, Schalk G, Braun C, Preiss! H, Rosenstiel W, Birbaumer N, et al. An MEG-based brain-computer interface (BCI) . Neuroimage 2007 Jul 1;36(3) :581 -93. 31 Ohta H, Matsui T, Uchikawa Y. Whole-head SQUID system in a superconducting magnetic shield. Neural Clin Neurophysiol 2004;2004:58 . 32 Kraus RH, Jr., Volegov P, Matlachov A, Espy M. Toward direct neural current imaging by resonant mechanisms at ultra-low field. Neuroimage 2008 Jan 1;39(1) :310-7. 33 McDermott R, Lee S, ten Haken B, Trabesinger AH, Pines A, Clarke J. Microtesla MRI with a superconducting quantum interference dev ice. Proc Natl Acad Sci US A 2004 May 25;101(21):7857-61. 34 Chen Y, Intes X, Tailor DR, Regatte RR, Ma H, Ntziachristos V, et al. Probing rat brain oxygenation with near­ infrared spectroscopy (NIRS) and magnetic resonance imaging (MRI). Adv Exp Med Biol 2003;510:199-204. 35 Luu S, Chau T. Decoding subjective preference from single-trial near-infrared spectroscopy signals. J Neural Eng 2009 Feb;6(1):016003 . 36 Loeb GE. Cochlear prosthetics. Annu Rev Neurosci 1990;13 :357-71. 37 Bailey L. New cochlear implant could improve hearing. University of Michigan News Service [serial on t he Internet]. 2006: Available from : http ://www . umich .edu/news/ index . html?Releases/2006/Feb06/r020606a . 38 Cheng YC, Brown RW, Chung YC, Duerk JL, Fujita H, Lewin JS, et al. Calculated RF electric field and temperature distributions in RF therma l ablation: comparison with gel experiments and liver imaging. J Magn Reson Imag ing 1998 Jan-Feb;8(1) :70-6. 39 Kamitani Y, Tong F. Decoding the visual and subjective contents of the human brain . Nat Neurosci 2005 May;8(5): 679-85. 4 °Kamitani Y, Tong F. Decoding seen and attended motion directions from activity in the human visual cortex . Curr Biol 2006 Jun 6;16(11):1096-102 . 41 Fagg AH, Hatsopoulos NG, de Lafuente V, Maxon KA, Nemati S, Rebesco JM, et al. Biomimetic brain machine interfaces for the control of movement. J Neurosci 2007 Oct 31;27(44 ): 11842-6. 42 Kim HK, Carmena JM, Biggs SJ, Hanson TL, Nicolelis MA, Srinivasan MA. The muscle activation method : an approach to impedance control of brain-machine interfaces through a muscu loskeletal model of the arm. IEEE Trans Biomed Eng 2007 Aug;54(8) : 1520 -9. 43 Kawata M. Brain control led robots . HFSP J 2008 Jun;2(3) : 136-42. 44 Jackson A, Moritz CT, Mavoori J, Lucas TH, Fetz EE. The Neurochip BCI: towards a neural prosthesis for upper limb function. IEEE Trans Neura l Syst Rehabil Eng 2006 Jun;14(2): 187-90. 45 Leuthardt EC, Miller KJ, Schalk G, Rao RP, Ojemann JG. Electrocorticography-based brain computer interface- ­ the Seattle experience. IEEE Trans Neural Syst Reha bi I Eng 2006 Jun; 14(2) : 194-8. 46 Diorio C, Mavoori J. Computer electron ics meet animal brains . IEEE Computer 2003;36(1) :69 -75. 4 7 Parikh H, Marzullo TC, Kipke DR. Lower layers in the motor cortex are more effective targets for penetrating microelectrodes in cortical prostheses . J Neural Eng 2009 Apr;6(2):026004 . 29 UNCLASSIFIED/ f FOA QFFI&IAk WSE 8,.L'/

Editorial note: Bibliographic references kept in their original form (authors, titles and journals), as is standard practice in citations.

Check the original PDF
¹⁶ Cummings ML, Guerlain S. Developing operator capacity estimates for supervisory control of autonomous vehicles. Hum Factors 2007 Feb;49(1):1-15. ¹⁷ Enzinger C, Ropele S, Fazekas F, Loitfelder M, Gorani F, Seifert T, et al. Brain motor system function in a patient with complete spinal cord injury following extensive brain-computer interface training. Exp Brain Res 2008 Sep;190(2):215-23. ¹⁸ Berger H. Uber das elektrenkephalogramm des menschen. Archiv fur Psychiatrie und Nervenkrankheiten 1929;87(1):527-80. ¹⁹ Davis P. Effects of acoustic stimuli on the waking human brain. Journal of Neurophysiology 1939;2:494-9. ²⁰ Blankertz B, Dornhege G, Krauledat M, Muller KR, Curio G. The non-invasive Berlin Brain-Computer Interface: fast acquisition of effective performance in untrained subjects. Neuroimage 2007 Aug 15;37(2):539-50. ²¹ Kubler A, Kotchoubey B, Kaiser J, Wolpaw JR, Birbaumer N. Brain-computer communication: unlocking the locked in. Psychol Bull 2001 May;127(3):358-75. ²² Bai O, Lin P, Vorbach S, Floeter MK, Hattori N, Hallett M. A high performance sensorimotor beta rhythm-based brain-computer interface associated with human natural motor behavior. J Neural Eng 2008 Mar;5(1):24-35. ²³ Iversen I, Ghanayim N, Kubler A, Neumann N, Birbaumer N, Kaiser J. Conditional associative learning examined in a paralyzed patient with amyotrophic lateral sclerosis using brain-computer interface technology, Behav Brain Funct 2008;4:53. ²⁴ Iversen IH, Ghanayim N, Kubler A, Neumann N, Birbaumer N, Kaiser J. A brain-computer interface tool to assess cognitive functions in completely paralyzed patients with amyotrophic lateral sclerosis. Clin Neurophysiol 2008 Oct;119(10):2214-23. ²⁵ Sellers EW, Kubler A, Donchin E. Brain-computer interface research at the University of South Florida Cognitive Psychophysiology Laboratory: the P300 Speller. IEEE Trans Neural Syst Rehabil Eng 2006 Jun;14(2):221-4. ²⁶ Greene K. Brain sensor for market research: A startup claims to read people's minds while they view ads. 2007 [May 12, 2009]; Available from: http://www.technologyreview.com/Biztech/19833/?a=f. ²⁷ Greene K. Connecting Your Brain to the Game Using an EEG cap, a startup hopes to change the way people interact with video games. 2007 [May 12, 2009]; Available from: http://www.technologyreview.com/Biztech/18276/?a=f. ²⁸ Popescu F, Fazli S, Badower Y, Blankertz B, Muller KR. Single trial classification of motor imagination using 6 dry EEG electrodes. PLoS ONE 2007;2(7):e637. ²⁹ van Gerven M, Jensen O. Attention modulations of posterior alpha as a control signal for two-dimensional brain-computer interfaces. J Neurosci Methods 2009 Apr 30;179(1):78-84. ³⁰ Mellinger J, Schalk G, Braun C, Preissl H, Rosenstiel W, Birbaumer N, et al. An MEG-based brain-computer interface (BCI). Neuroimage 2007 Jul 1;36(3):581-93. ³¹ Ohta H, Matsui T, Uchikawa Y. Whole-head SQUID system in a superconducting magnetic shield. Neurol Clin Neurophysiol 2004;2004:58. ³² Kraus RH, Jr., Volegov P, Matlachov A, Espy M. Toward direct neural current imaging by resonant mechanisms at ultra-low field. Neuroimage 2008 Jan 1;39(1):310-7. ³³ McDermott R, Lee S, ten Haken B, Trabesinger AH, Pines A, Clarke J. Microtesla MRI with a superconducting quantum interference device. Proc Natl Acad Sci US A 2004 May 25;101(21):7857-61. ³⁴ Chen Y, Intes X, Tailor DR, Regatte RR, Ma H, Ntziachristos V, et al. Probing rat brain oxygenation with near-infrared spectroscopy (NIRS) and magnetic resonance imaging (MRI). Adv Exp Med Biol 2003;510:199-204. ³⁵ Luu S, Chau T. Decoding subjective preference from single-trial near-infrared spectroscopy signals. J Neural Eng 2009 Feb;6(1):016003. ³⁶ Loeb GE. Cochlear prosthetics. Annu Rev Neurosci 1990;13:357-71. ³⁷ Bailey L. New cochlear implant could improve hearing. University of Michigan News Service [serial on the Internet]. 2006: Available from: http://www.umich.edu/news/index.html?Releases/2006/Feb06/r020606a. ³⁸ Cheng YC, Brown RW, Chung YC, Duerk JL, Fujita H, Lewin JS, et al. Calculated RF electric field and temperature distributions in RF thermal ablation: comparison with gel experiments and liver imaging. J Magn Reson Imaging 1998 Jan-Feb;8(1):70-6. ³⁹ Kamitani Y, Tong F. Decoding the visual and subjective contents of the human brain. Nat Neurosci 2005 May;8(5):679-85. ⁴⁰ Kamitani Y, Tong F. Decoding seen and attended motion directions from activity in the human visual cortex. Curr Biol 2006 Jun 6;16(11):1096-102. ⁴¹ Fagg AH, Hatsopoulos NG, de Lafuente V, Maxon KA, Nemati S, Rebesco JM, et al. Biomimetic brain machine interfaces for the control of movement. J Neurosci 2007 Oct 31;27(44):11842-6. ⁴² Kim HK, Carmena JM, Biggs SJ, Hanson TL, Nicolelis MA, Srinivasan MA. The muscle activation method: an approach to impedance control of brain-machine interfaces through a musculoskeletal model of the arm. IEEE Trans Biomed Eng 2007 Aug;54(8): 1520-9. ⁴³ Kawata M. Brain controlled robots. HFSP J 2008 Jun;2(3): 136-42. ⁴⁴ Jackson A, Moritz CT, Mavoori J, Lucas TH, Fetz EE. The Neurochip BCI: towards a neural prosthesis for upper limb function. IEEE Trans Neural Syst Rehabil Eng 2006 Jun;14(2):187-90. ⁴⁵ Leuthardt EC, Miller KJ, Schalk G, Rao RP, Ojemann JG. Electrocorticography-based brain computer interface--the Seattle experience. IEEE Trans Neural Syst Rehabil Eng 2006 Jun;14(2):194-8. ⁴⁶ Diorio C, Mavoori J. Computer electronics meet animal brains. IEEE Computer 2003;36(1):69 -75. ⁴⁷ Parikh H, Marzullo TC, Kipke DR. Lower layers in the motor cortex are more effective targets for penetrating microelectrodes in cortical prostheses. J Neural Eng 2009 Apr;6(2):026004.

View the document record ↗ · Physical page 35, counting the cover.

EXCERPT 39 · PHYSICAL PAGE 36

D130, physical page 36: reference notes

UNCLASSIFIED/ /FOR 8FFl&IAL l:ISE 8HLY 48 Baker KB, Nyenhuis JA, Hrdlicka G, Rezai AR, Tkach JA, Shellock FG. Neurostimulat ion systems: assessment of magnetic field interactions associated with 1.5- and 3-Tesla MR systems . J Magn Reson Imaging 2005 Jan;21(1):72 -7. 49 Wise KO. Silicon microsystems for neuroscience and neural prostheses . IEEE Eng Med Biol Mag 2005 Sep­ Oct;24(5) : 22-9 . 50 Martinez Santiesteban FM, Swanson SD, Noll DC, Anderson DJ. Magnetic resonance compatibility of multichannel silicon microelectrode systems for neural recording and stimulation: design criteria, tests, and recommendat ions. IEEE Trans Biomed Eng 2006 Mar;53(3) :547-58. 51 Paralikar KJ, Neuberge r T, Matsui JT, Barber AJ, Webb A, Clement RS. Feasibility and safety of longitudinal magnetic resonance imaging in a rodent model with intracortical microwire implants. J Neural Eng 2009 Apr 15;6(3) :34001. 52 Blakely T, Miller KJ, Rao RP, Holmes MD, Ojemann JG . Loca lization and classification of phonemes using high spatial resolution electrocorticography (ECoG) grids. Conf Proc IEEE Eng Med Biol Soc 2008;2008:4964-7. 53 Schalk G, Miller KJ, Anderson NR, Wilson JA, Smyth MD, Ojemann JG, et al. Two-dimensional movement control using electrocorticographic signals in humans . J Neural Eng 2008 Mar;5(1):75-84 . 54 Marquez-Chin C, Popovic MR, Cameron T, Lozano AM, Chen R. Control of a neuroprosthesis for grasping using off-line classification of electrocorticographic signals: case study . Spinal Cord 2009 Apr 21. 55 Hochberg LR, Serruya MD, Friehs GM, Mukand JA, Saleh M, Caplan AH, et al. Neuronal ensemble control of prosthetic devices by a human with tetraplegia. Nature 2006 Jul 13;442(7099): 164-71. 56 Kuiken TA, Li G, Lock BA, Lipschutz RD, Miller LA, Stubblef ield KA, et al. Targeted muscle reinnervation for real­ time myoelectric control of multifunction artificial arms . JAMA 2009 Feb 11;301(6):619-28 . 57 Kuiken T. Targeted reinnervation for improved prosthetic function. Phys Med Rehabil Clin N Am 2006 Feb; 17(1) : 1-13 . 58 Warwick K, Gasson M, Hutt B, Goodhew I, Kyberd P, Andrews B, et al. The application of implant techno logy for cybernetic systems. Arch Neural 2003 Oct;60(10) :1369-73. 59 Nagel G, Szellas T, Huhn W, Kateriya S, Adeishvili N, Berthold P, et al. Channelrhodopsin-2, a directly light-gated cation-selective membrane channel . Proc Natl Acad Sci US A 2003 Nov 25;100(24) :13940-5 . 60 Degenaar P, Grossman N, Memon MA, Burrone J, Dawson M, Drakakis E, et al. Optobionic vision--a new genetical ly enhanced light on retinal prosthesis . J Neural Eng 2009 Jun;6(3):035007 . UNCLASSIFIED/ /FOR OFFI&il.t.k W&liii OP•k¥ 30

Editorial note: Bibliographic references kept in their original form (authors, titles and journals), as is standard practice in citations.

Check the original PDF
⁴⁸ Baker KB, Nyenhuis JA, Hrdlicka G, Rezai AR, Tkach JA, Shellock FG. Neurostimulation systems: assessment of magnetic field interactions associated with 1.5- and 3-Tesla MR systems. J Magn Reson Imaging 2005 Jan;21(1):72-7. ⁴⁹ Wise KD. Silicon microsystems for neuroscience and neural prostheses. IEEE Eng Med Biol Mag 2005 Sep-Oct;24(5): 22-9. ⁵⁰ Martinez Santiesteban FM, Swanson SD, Noll DC, Anderson DJ. Magnetic resonance compatibility of multichannel silicon microelectrode systems for neural recording and stimulation: design criteria, tests, and recommendations. IEEE Trans Biomed Eng 2006 Mar;53(3):547-58. ⁵¹ Paralikar KJ, Neuberger T, Matsui JT, Barber AJ, Webb A, Clement RS. Feasibility and safety of longitudinal magnetic resonance imaging in a rodent model with intracortical microwire implants. J Neural Eng 2009 Apr 15;6(3):34001. ⁵² Blakely T, Miller KJ, Rao RP, Holmes MD, Ojemann JG. Localization and classification of phonemes using high spatial resolution electrocorticography (ECoG) grids. Conf Proc IEEE Eng Med Biol Soc 2008;2008:4964-7. ⁵³ Schalk G, Miller KJ, Anderson NR, Wilson JA, Smyth MD, Ojemann JG, et al. Two-dimensional movement control using electrocorticographic signals in humans. J Neural Eng 2008 Mar;5(1):75-84. ⁵⁴ Marquez-Chin C, Popovic MR, Cameron T, Lozano AM, Chen R. Control of a neuroprosthesis for grasping using off-line classification of electrocorticographic signals: case study. Spinal Cord 2009 Apr 21. ⁵⁵ Hochberg LR, Serruya MD, Friehs GM, Mukand JA, Saleh M, Caplan AH, et al. Neuronal ensemble control of prosthetic devices by a human with tetraplegia. Nature 2006 Jul 13;442(7099):164-71. ⁵⁶ Kuiken TA, Li G, Lock BA, Lipschutz RD, Miller LA, Stubblefield KA, et al. Targeted muscle reinnervation for real-time myoelectric control of multifunction artificial arms. JAMA 2009 Feb 11;301(6):619-28. ⁵⁷ Kuiken T. Targeted reinnervation for improved prosthetic function. Phys Med Rehabil Clin N Am 2006 Feb;17(1):1-13. ⁵⁸ Warwick K, Gasson M, Hutt B, Goodhew I, Kyberd P, Andrews B, et al. The application of implant technology for cybernetic systems. Arch Neurol 2003 Oct;60(10):1369-73. ⁵⁹ Nagel G, Szellas T, Huhn W, Kateriya S, Adeishvili N, Berthold P, et al. Channelrhodopsin-2, a directly light-gated cation-selective membrane channel. Proc Natl Acad Sci US A 2003 Nov 25;100(24):13940-5. ⁶⁰ Degenaar P, Grossman N, Memon MA, Burrone J, Dawson M, Drakakis E, et al. Optobionic vision--a new genetically enhanced light on retinal prosthesis. J Neural Eng 2009 Jun;6(3):035007.

View the document record ↗ · Physical page 36, counting the cover.

EXCERPT 40 · PHYSICAL PAGE 3

D136, physical page 3: table of contents

UNCLASSIFIED/ / P'OR: OP'P'l@IA L WS& 0Nk¥ Contents Introduction ..................................................... ........... .. ....... ........ ..... .... ... .......... .... vi What is BioMEMS? ....... .... ........ ...... ........ ...... ..... ..... ........ .. .................... ................... 1 Characteristics of BioMEMS ....... ........ ...... .... ...... ............... .................................. 2 Categories of BioMEMS .... ............ ...... ........ ...................... ............ ...... ........... ...... 3 BioMEMS Micromachines ........................................................................................ 3 Brain -Implanted BioMEMS Mic romachine Neuroelectrodes ................... ..... .... .... 4 Fluidi c BioMEMS ..................................................................................................... 6 Drug-Delivery Pumps ......................................................................................... 7 What is a Biosensor? .............................................................................................. 9 BioMEMS Implantable Sensors ............................................................................. 10 MEMS Blood Glucose Sensors ............................................................................... 13 Commercial Blood Glucose Sensors .................................................................. 14 Enzyme-Based Biosensors ................................................................................ 14 Thermopile Implantable Glucose Sensors ........................................................ 15 Neuroengineering by BioMEMS ............................................................................. 20 Bioelectric Events ............................................................................................. 20 Bionics and Neurointerfaces ................................................................................. 22 Bioelectrodes and Bio MEMS ............................................................................. 22 Microelectrode Array Fabrication ..................................................................... 24 Brain-Machine Interfaces ................................................................................. 25 Polymer BioMEMS Electrodes ........................................................................... 26 Retinal Devices Using BioMEMS ........................................................................ 27 Microscale in Therapeutic Neurostimulation ..................................................... 30 MEMS in Microfluidics ........................................................................................... 32 Lab Chips ......................................................................................................... 33 UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ iii
Check the original PDF
Contents Introduction ... vi What is BioMEMS? ... 1 Characteristics of BioMEMS ... 2 Categories of BioMEMS ... 3 BioMEMS Micromachines ... 3 Brain-Implanted BioMEMS Micromachine Neuroelectrodes ... 4 Fluidic BioMEMS ... 6 Drug-Delivery Pumps ... 7 What is a Biosensor? ... 9 BioMEMS Implantable Sensors ... 10 MEMS Blood Glucose Sensors ... 13 Commercial Blood Glucose Sensors ... 14 Enzyme-Based Biosensors ... 14 Thermopile Implantable Glucose Sensors ... 15 Neuroengineering by BioMEMS ... 20 Bioelectric Events ... 20 Bionics and Neurointerfaces ... 22 Bioelectrodes and BioMEMS ... 22 Microelectrode Array Fabrication ... 24 Brain-Machine Interfaces ... 25 Polymer BioMEMS Electrodes ... 26 Retinal Devices Using BioMEMS ... 27 Microscale in Therapeutic Neurostimulation ... 30 MEMS in Microfluidics ... 32 Lab Chips ... 33

View the document record ↗ · Physical page 3, counting the cover.

EXCERPT 41 · PHYSICAL PAGE 4

D136, physical page 4: table of contents (end) and list of figures (1 to 29)

UNCLASSIFIED/ / P'OR: OP'P'l@IA L WS& 0Nk¥ NASA Space Applications for Microfluidic Systems ........ ........... ......... ......... ...... 34 Microcant ilever MEMs Sensors ....... ....... ...... ... .............. ... ...... .... ............ .... ........ ... 36 Conclus ion ....... ......... ......... ....... ............. ......... ..... .... ............................................. 39 Figures Figure 1. Varieties of BioMEMS and Sensors ..................................................... ...... 2 Figure 3. Schemati c Diagram of a MEMS Motor Complete With a Method of Figure 7. An ISFET (Ion Sensitive Field Effect Transistor) Needle-Type pH Sensor Figure 9. Control of an Insulin-Delivery System by an Implantable Glucose Figure 2. Funct ional MEMS Micromachines At tached to Sensing Bioe lectrodes ... .... 5 Converting Oscillatory Motion to Linear Motion ....................................... 5 Figure 4 . Illustration of the Basic Physical Principle of the BioMEMS Motor ..... ...... 6 Figure 5. Close-up Views of the Mic ro-Moto r Gear .......... .... ................ ................ .... 6 Figu re 6. An Insulin MEMS Pump ............................................................................ 8 for Monitoring Tissue Physiologic Status ............................................... 11 Figure 8. A Fiber Optical Oxygen Sensor .............................................................. 12 Sensor ................................................................................................... 13 Figure 10. Glucose Oxidase .................................................................................. 14 Figure 11. An Experimental MEMS Blood Glucose Sensor ..................................... 15 Figure 12. Photomicrograph ................................................................................. 16 Figure 13. A MEMS Thermopile Glucose Sensor .................................................... 17 Figure 15. Thermopile Glucose Sensor (left) With Functional Illustration (right) Figure 16. Photograph and Illustration of the Thermopile Glucose Sensor in a Figure 18. A Neural Cell Showing Dendritic Inter-Connections That are Electrically Figure 14. Illustration of the Thermocouple Principle .......................................... 18 are Made Using Photolithographic Techniques .................................... 19 Catheter .............................................................................................. 19 Figure 17. A MEMS Biopotential Electrode System ................................................ 20 Active With Other Cells........................................................................ 21 Figure 19. A Neuroprosthetic Interface ................................................................ 22 Figure 20. Scanning Electron Micrograph of a Brain Electrode Array Manufactured From Titanium and Produced by a Process of Electrodischarge Figure 21. Scanning Electron Micrograph of a 1141 Electrode Array Made to Be Figure 22. Polymer Based Cortical Penetrating Neuroelectrodes Made by Processes Figure 23. A MEMS Microelectrode Array Implanted Into the Cortex of a Rat Brain Figure 26. An Illustration of the Retinal Neuroprosthesis Created by the Boston Figure 27. Power Transfer by Magnetic Induction to an Implanted BioMEMS Retinal Figure 28. A New Generation of Implantable Neurostimulation Devices Can Pass Figure 29. Illustration of the Internal Construction of the Ultrasound Powered Machining ............................................................................................ 23 Inserted Into the Surface of the Human Brain .................................... 25 of Thin Film Deposition and RF Etching ............................................... 26 ............................................................................................................ 27 Figure 24. A Representation of the Retinal Prosthesis ......................................... 28 Figure 25. A BioMEMS Fabricated 4x4 Microelectrode Retinal Array ..................... 28 Implant Project ................................................................................... 29 Prosthesis ........................................................................................... 30 Through the Lumen of a Syringe Needle .............................................. 31 Neurostimulator Developed at ASU ..................................................... 32 UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ iv
Check the original PDF
NASA Space Applications for Microfluidic Systems ... 34 Microcantilever MEMs Sensors ... 36 Conclusion ... 39 Figures Figure 1. Varieties of BioMEMS and Sensors ... 2 Figure 2. Functional MEMS Micromachines Attached to Sensing Bioelectrodes ... 5 Figure 3. Schematic Diagram of a MEMS Motor Complete With a Method of Converting Oscillatory Motion to Linear Motion ... 5 Figure 4. Illustration of the Basic Physical Principle of the BioMEMS Motor ... 6 Figure 5. Close-up Views of the Micro-Motor Gear ... 6 Figure 6. An Insulin MEMS Pump ... 8 Figure 7. An ISFET (Ion Sensitive Field Effect Transistor) Needle-Type pH Sensor for Monitoring Tissue Physiologic Status ... 11 Figure 8. A Fiber Optical Oxygen Sensor ... 12 Figure 9. Control of an Insulin-Delivery System by an Implantable Glucose Sensor ... 13 Figure 10. Glucose Oxidase ... 14 Figure 11. An Experimental MEMS Blood Glucose Sensor ... 15 Figure 12. Photomicrograph ... 16 Figure 13. A MEMS Thermopile Glucose Sensor ... 17 Figure 14. Illustration of the Thermocouple Principle ... 18 Figure 15. Thermopile Glucose Sensor (left) With Functional Illustration (right) are Made Using Photolithographic Techniques ... 19 Figure 16. Photograph and Illustration of the Thermopile Glucose Sensor in a Catheter ... 19 Figure 17. A MEMS Biopotential Electrode System ... 20 Figure 18. A Neural Cell Showing Dendritic Inter-Connections That are Electrically Active With Other Cells ... 21 Figure 19. A Neuroprosthetic Interface ... 22 Figure 20. Scanning Electron Micrograph of a Brain Electrode Array Manufactured From Titanium and Produced by a Process of Electrodischarge Machining ... 23 Figure 21. Scanning Electron Micrograph of a 1141 Electrode Array Made to Be Inserted Into the Surface of the Human Brain ... 25 Figure 22. Polymer Based Cortical Penetrating Neuroelectrodes Made by Processes of Thin Film Deposition and RF Etching ... 26 Figure 23. A MEMS Microelectrode Array Implanted Into the Cortex of a Rat Brain ... 27 Figure 24. A Representation of the Retinal Prosthesis ... 28 Figure 25. A BioMEMS Fabricated 4x4 Microelectrode Retinal Array ... 28 Figure 26. An Illustration of the Retinal Neuroprosthesis Created by the Boston Implant Project ... 29 Figure 27. Power Transfer by Magnetic Induction to an Implanted BioMEMS Retinal Prosthesis ... 30 Figure 28. A New Generation of Implantable Neurostimulation Devices Can Pass Through the Lumen of a Syringe Needle ... 31 Figure 29. Illustration of the Internal Construction of the Ultrasound Powered Neurostimulator Developed at ASU ... 32

View the document record ↗ · Physical page 4, counting the cover.

EXCERPT 42 · PHYSICAL PAGE 5

D136, physical page 5: list of figures (30 to 36)

UNCLASSIFIED/ /P"OR: OP"P"l@IAL HS& 91'11.¥ Figure 30. Microfluidics in Glass ........................................................................... 32 Figure 31. Commercial Lab-Chip Devices That Allow Analysis for Biomarkers of Figure 32. Design of an Automated Cell Culture System for NASA Space Applications Incorporating Microfluidics and Integrated Optical Various Diseases Using On-Chip Electrophoresis in Microscale ........... 34 Components ........................................................................................ 35 Figure 33. NASA Space Application of Microfluidic Cell Culture System Made by Figure 34. Principle of a Microcantilever That Bends When It is Loaded With an Figure 35. Scanning Electron Micrograph Showing a Cantilever Beam With a Single Micromachining ................................................................................... 36 Adherent Mass .......................................................................... .......... 37 Vaccinia Virus Particle ......................................................................... 38 Figure 36. Antibodies Attached to a Cantilever Array Create Different Specificities to Substances in Blood That are Indicative of Cancer .......................... 38 UNCLASSIFIED/ (FOR OFFICIO! 1155 01!1.¥ V
Check the original PDF
Figure 30. Microfluidics in Glass ... 32 Figure 31. Commercial Lab-Chip Devices That Allow Analysis for Biomarkers of Various Diseases Using On-Chip Electrophoresis in Microscale ... 34 Figure 32. Design of an Automated Cell Culture System for NASA Space Applications Incorporating Microfluidics and Integrated Optical Components ... 35 Figure 33. NASA Space Application of Microfluidic Cell Culture System Made by Micromachining ... 36 Figure 34. Principle of a Microcantilever That Bends When It is Loaded With an Adherent Mass ... 37 Figure 35. Scanning Electron Micrograph Showing a Cantilever Beam With a Single Vaccinia Virus Particle ... 38 Figure 36. Antibodies Attached to a Cantilever Array Create Different Specificities to Substances in Blood That are Indicative of Cancer ... 38

View the document record ↗ · Physical page 5, counting the cover.

EXCERPT 43 · PHYSICAL PAGE 7

D136, physical page 7: what are BioMEMS?

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ What is BioM EMS? BioMEMS stands for biomedical micro-_glectro-mechanical ~ystems. It is a name applied to biological and medical devices that are created using advanced fabrication processes that allow the devices to be very small relative to comparable devices produced by traditional techniques. BioMEMS devices can also exploit the microscale to provide new functions that are not practical or possible in large-scale devices. The name applies to an exceptionally wide variety of engineered devices that derive from electrical, mechanical, chemical, and molecu lar engineering. The name distinguishes these from nanoMEMS which are submicron in scale such as carbon nanotube structures. Recently BioMEMS has become something of a misnomer as many of the latest technologies are being designed and developed based on nanoscale technologies which are many times smaller than microscale techno logies. While current devices are manufactured mostly on the microscale, many of the functioning parts and the materials they operate on are at the nanoscale level. NanoMEMS for biomedical applications are mostly carbon-based materials that have emerged as prime materials because of their favorable mechanical and electrical properties. Carbon-based nanostr uctures such as graphene exhibit a high Young's modulus (stiffness), high strength, low density, low friction and large surface area. The low friction of a carbon nanotube allows product ion of practically frictionless bearings and has thus been a huge motivation towards applications such as nanomotors. Carbon nanostructure s are much stronger than steel, which allows carbon-based materials to meet high-stress demands in biomedical applications such as weight-bearing prosthetics (like hip-joint or bone replacements), where other materials would fail. The field of BioMEMS encompasses micro devices that are often but not exclusively made by the same photo lithographic techniques used to make computer chips. Their applications include neuroprosthetics, sensors and actuators, and microchemistry systems. A microchemistry system, often called a lab on a chip, can analyze chemical properties of a very small quantity of material such as a tiny blood sample. Advanced systems can perform several tests on the sample at one time. There are also drug-delivery systems, miniature hearing aids, artificial retinas, DNA analysis systems, cancer diagnostics, and an amazing variety of devices which support the function of the human body. Figure 1 shows some devices that were developed by the faculty of Biomedical Engineering at Arizona State Universit y. UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ 1
Check the original PDF
What is BioMEMS? BioMEMS stands for biomedical micro-electro-mechanical systems. It is a name applied to biological and medical devices that are created using advanced fabrication processes that allow the devices to be very small relative to comparable devices produced by traditional techniques. BioMEMS devices can also exploit the microscale to provide new functions that are not practical or possible in large-scale devices. The name applies to an exceptionally wide variety of engineered devices that derive from electrical, mechanical, chemical, and molecular engineering. The name distinguishes these from nanoMEMS which are submicron in scale such as carbon nanotube structures. Recently BioMEMS has become something of a misnomer as many of the latest technologies are being designed and developed based on nanoscale technologies which are many times smaller than microscale technologies. While current devices are manufactured mostly on the microscale, many of the functioning parts and the materials they operate on are at the nanoscale level. NanoMEMS for biomedical applications are mostly carbon-based materials that have emerged as prime materials because of their favorable mechanical and electrical properties. Carbon-based nanostructures such as graphene exhibit a high Young's modulus (stiffness), high strength, low density, low friction and large surface area. The low friction of a carbon nanotube allows production of practically frictionless bearings and has thus been a huge motivation towards applications such as nanomotors. Carbon nanostructures are much stronger than steel, which allows carbon-based materials to meet high-stress demands in biomedical applications such as weight-bearing prosthetics (like hip-joint or bone replacements), where other materials would fail. The field of BioMEMS encompasses micro devices that are often but not exclusively made by the same photolithographic techniques used to make computer chips. Their applications include neuroprosthetics, sensors and actuators, and microchemistry systems. A microchemistry system, often called a lab on a chip, can analyze chemical properties of a very small quantity of material such as a tiny blood sample. Advanced systems can perform several tests on the sample at one time. There are also drug-delivery systems, miniature hearing aids, artificial retinas, DNA analysis systems, cancer diagnostics, and an amazing variety of devices which support the function of the human body. Figure 1 shows some devices that were developed by the faculty of Biomedical Engineering at Arizona State University.

View the document record ↗ · Physical page 7, counting the cover.

EXCERPT 44 · PHYSICAL PAGE 8

D136, physical page 8: Figure 1 and characteristics of BioMEMS

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ Varieties of BioMEMs and Sensors --- ---· ·-•· --- . I . . I . ---· ---· ---· Figure 1. Varietie .s of BioMEMS and Sensors. These BioMEMS devices were made at Arizona State University (ASU). They represent many of the areas of BioMEMS research. CHARACTERISTICS OF BIOMEMS Conceiving and designing BioMEMS devices requires a different perspective of the physical world. These devices can operate on principles such as capillary force, van der Waals forces, and electric-field forces. These forces become relatively strong when the size scale reaches very small dimensions. In the realm of the very small, the force of gravity is far less important than electrical charge and viscosity. From the perspective of microscale devices, engineers need to think about accomplishing tasks on an extremely subtle scale but with an exceptionally effective result. BioMEMS employs engineering sciences in ways that are more than just scaling down familiar devices used in biomedical applications. Rather, employment of new structures and new materials including polymers and biological components is necessary. In addition we need to be concerned about things like biocompatibility (the effect of the device on body tissue) as well as the degradation effects of tissues and body fluids on the device itself. Development of a new product that is targeted for implantatio n into the human body is particularly expensive due to federal regulation of medical devices. Devices must be shown to be effective for their intended use, and above all devices must be proved safe. Bringing a new device to market is not unlike the development of a new drug. In order UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ 2
Check the original PDF
[Figure 1 labels: Varieties of BioMEMs and Sensors; ASU; SEM of gear assembly] Figure 1. Varieties of BioMEMS and Sensors. These BioMEMS devices were made at Arizona State University (ASU). They represent many of the areas of BioMEMS research. CHARACTERISTICS OF BIOMEMS Conceiving and designing BioMEMS devices requires a different perspective of the physical world. These devices can operate on principles such as capillary force, van der Waals forces, and electric-field forces. These forces become relatively strong when the size scale reaches very small dimensions. In the realm of the very small, the force of gravity is far less important than electrical charge and viscosity. From the perspective of microscale devices, engineers need to think about accomplishing tasks on an extremely subtle scale but with an exceptionally effective result. BioMEMS employs engineering sciences in ways that are more than just scaling down familiar devices used in biomedical applications. Rather, employment of new structures and new materials including polymers and biological components is necessary. In addition we need to be concerned about things like biocompatibility (the effect of the device on body tissue) as well as the degradation effects of tissues and body fluids on the device itself. Development of a new product that is targeted for implantation into the human body is particularly expensive due to federal regulation of medical devices. Devices must be shown to be effective for their intended use, and above all devices must be proved safe. Bringing a new device to market is not unlike the development of a new drug. In order

View the document record ↗ · Physical page 8, counting the cover.

EXCERPT 45 · PHYSICAL PAGE 9

D136, physical page 9: BioMEMS categories and BioMEMS micromachines

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ to gain federal approval there may be biocompatibility issues to resolve, clinical trials to perform, and Food and Drug Administration (FDA) requirements to satisfy. CATEGORIES OF BIOMEMS We divide the BioMEMS field into several subcategories. Some devices are targeted to be implanted into the human body or are applied to the body. Many of these are being developed as alternatives to drugs which therapeutically treat illness or disease. There is also activity in using microscale stimulation devices to treat neurological disorders such as epilepsy and Parkinson's disease and to treat neuro logical injuries such as stroke or trauma to the spinal cord. Another promising field of research is directed towards integration of the human brain with microelectrical components. For example implants are being developed which allow volitional (thought) control of machines. Most of this effort is targeted towards rehabilitation of individuals who are quadriplegics in order to allow them some control over their environment. Then there are devices being developed for clinical applications such as rapid blood analysis, and there are those targeted for benchtop biological research. I n this review, the focus is on specific microscale and MEMS-based devices t hat are used in medicine and biology. These include: • Micromachines that interface to brain electrodes. • Blood glucose sensors. • Microfluidics. • Neural Interfaces. • Neurostimulators. • Microbeam sensors. Several of these technologies have been the subject of research by the present author and by colleagues at Arizona State University. BioMEMS Micromachines Micromachines made by photol ithography are among the most complex and sophisticated of all MEMS devices. They have seen some application in various forms of biomedical devices where motion must be achieved with an implantable device. Motion within the human body by a device is difficult since it implies sliding surfaces, a need for electrical power, and long term reliability and stability. Biomedical implants are usually introduced by surgery and so once implanted cannot be easily removed for servicing. UNCLASSIFIED/ (FOR OFFICIO! P!Sli Qllk¥ 3
Check the original PDF
to gain federal approval there may be biocompatibility issues to resolve, clinical trials to perform, and Food and Drug Administration (FDA) requirements to satisfy. CATEGORIES OF BIOMEMS We divide the BioMEMS field into several subcategories. Some devices are targeted to be implanted into the human body or are applied to the body. Many of these are being developed as alternatives to drugs which therapeutically treat illness or disease. There is also activity in using microscale stimulation devices to treat neurological disorders such as epilepsy and Parkinson's disease and to treat neurological injuries such as stroke or trauma to the spinal cord. Another promising field of research is directed towards integration of the human brain with microelectrical components. For example implants are being developed which allow volitional (thought) control of machines. Most of this effort is targeted towards rehabilitation of individuals who are quadriplegics in order to allow them some control over their environment. Then there are devices being developed for clinical applications such as rapid blood analysis, and there are those targeted for benchtop biological research. In this review, the focus is on specific microscale and MEMS-based devices that are used in medicine and biology. These include: • Micromachines that interface to brain electrodes. • Blood glucose sensors. • Microfluidics. • Neural Interfaces. • Neurostimulators. • Microbeam sensors. Several of these technologies have been the subject of research by the present author and by colleagues at Arizona State University. BioMEMS Micromachines Micromachines made by photolithography are among the most complex and sophisticated of all MEMS devices. They have seen some application in various forms of biomedical devices where motion must be achieved with an implantable device. Motion within the human body by a device is difficult since it implies sliding surfaces, a need for electrical power, and long term reliability and stability. Biomedical implants are usually introduced by surgery and so once implanted cannot be easily removed for servicing.

View the document record ↗ · Physical page 9, counting the cover.

EXCERPT 46 · PHYSICAL PAGE 10

D136, physical page 10: BioMEMS micromachine neuroelectrodes implanted in the brain

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ Only a few BioMEMS applications are well known for implanted devices and these are used for positioning and repositioning of sensors. A specific example is application to brain-electrode systems. BRAIN-IMPLANTED BIOMEMS MICROMACHINE NEUROELECTRODES There are applications in biomedicine and research where very small electrodes are implanted into the brain. These microelectrodes are used in the cortex (surface layer) to detect electrical activity associated with the volitional desire to move some part of the body. Electrical activity is recorded as a very small change in voltage within the tissue. Near the top of the human head and about 2 cm beneath the scalp lie the parts of the brain where nerve cells (neurons) are found which control the muscles of the body. Specific locations in the cortex are associated with specific parts of the body. When a person moves a limb , there can be detected a corresponding electrical activity of these neuro ns. Neuroscient ists have recorded these signals and developed a kind of map of the brain t hat defines what brain cells actuate certain muscles of the body. An interesting phenome non occurs in which some of these brain cells become active even when there is intent to move a limb but no actua l movement occurs . In a healt hy person the intent to move can be detected by measureme nt of microvolt signals from the brain cells about 120 milliseconds before any muscle movement occurs. In a person who has lost a limb or has become paralyzed, the intent to move can still be detected in the brain even though there is no limb movement. Thus in principle there is an ability to electr ically record from the brain and dete rmine a person's intent to move. Monitoring of the brain is accomplished by using an array of implanted microelectrodes whose signals ant icipate movement of specific limbs. These signals can in turn be used to contro l machines. This is the idea behind advanced devices that allow quadrip legics to interact with their environment. Signals from implanted electrodes are used by computers to control robotic actuators. A problem recording t he signals occurs because the body naturally tends to encapsulate the electrodes with scar tissue, meaning the electrodes lose electrica l contact with the neuro ns. A solutio n to this problem incorporates a very small electromechan ical actuator attached to the electrode. This device allows the implanted electrodes to change their position occasionally in order to continue to monito r n eural events . By moving t he thin rod-like electrode up or down a small distance after several months of implantat ion, the useful lifetime of the electrode array can be greatly extended. The BioMEMS device described here is meant to be implanted under the skull and on top of the brain cortex . It allows fine adjustme nt of less tha n a millimeter in order to make sure the electrode system, once implanted, is able to contact the desired brain cells even after the electrode has been encapsulated by scar tissue over t ime. Figure 2 shows a photomicrograph of a gear -driven micromachine that was made through collaboration between ASU and Sandia Nationa l Laboratories. The device is driven by an electrostatic vibrating comb moto r . Under a m icroscope it can be seen that the combs move in an oscillatory fashion at about 40 Hz when energized . Electrostat ic forces between two blade- like combs a few tens of microns apart are operative with about 15 volts as the electric field source. UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ 4
Check the original PDF
Only a few BioMEMS applications are well known for implanted devices and these are used for positioning and repositioning of sensors. A specific example is application to brain-electrode systems. BRAIN-IMPLANTED BIOMEMS MICROMACHINE NEUROELECTRODES There are applications in biomedicine and research where very small electrodes are implanted into the brain. These microelectrodes are used in the cortex (surface layer) to detect electrical activity associated with the volitional desire to move some part of the body. Electrical activity is recorded as a very small change in voltage within the tissue. Near the top of the human head and about 2 cm beneath the scalp lie the parts of the brain where nerve cells (neurons) are found which control the muscles of the body. Specific locations in the cortex are associated with specific parts of the body. When a person moves a limb, there can be detected a corresponding electrical activity of these neurons. Neuroscientists have recorded these signals and developed a kind of map of the brain that defines what brain cells actuate certain muscles of the body. An interesting phenomenon occurs in which some of these brain cells become active even when there is intent to move a limb but no actual movement occurs. In a healthy person the intent to move can be detected by measurement of microvolt signals from the brain cells about 120 milliseconds before any muscle movement occurs. In a person who has lost a limb or has become paralyzed, the intent to move can still be detected in the brain even though there is no limb movement. Thus in principle there is an ability to electrically record from the brain and determine a person's intent to move. Monitoring of the brain is accomplished by using an array of implanted microelectrodes whose signals anticipate movement of specific limbs. These signals can in turn be used to control machines. This is the idea behind advanced devices that allow quadriplegics to interact with their environment. Signals from implanted electrodes are used by computers to control robotic actuators. A problem recording the signals occurs because the body naturally tends to encapsulate the electrodes with scar tissue, meaning the electrodes lose electrical contact with the neurons. A solution to this problem incorporates a very small electromechanical actuator attached to the electrode. This device allows the implanted electrodes to change their position occasionally in order to continue to monitor neural events. By moving the thin rod-like electrode up or down a small distance after several months of implantation, the useful lifetime of the electrode array can be greatly extended. The BioMEMS device described here is meant to be implanted under the skull and on top of the brain cortex. It allows fine adjustment of less than a millimeter in order to make sure the electrode system, once implanted, is able to contact the desired brain cells even after the electrode has been encapsulated by scar tissue over time. Figure 2 shows a photomicrograph of a gear-driven micromachine that was made through collaboration between ASU and Sandia National Laboratories. The device is driven by an electrostatic vibrating comb motor. Under a microscope it can be seen that the combs move in an oscillatory fashion at about 40 Hz when energized. Electrostatic forces between two blade-like combs a few tens of microns apart are operative with about 15 volts as the electric field source.

View the document record ↗ · Physical page 10, counting the cover.

EXCERPT 47 · PHYSICAL PAGE 11

D136, physical page 11: the neural probe chip and Figures 2 and 3

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 8NI.¥ The Neural Probe chip enables precise bi-directional positioning of the microelectrodes in the brain with a step resolution in the order of 8.8 µm. The thermal microactuators allow for a movement of the microelectrodes of up to 5 mm in either direction making it suitable for positioning microelectrodes in deep structures of a rodent brain. The rest of the mechanism converts an oscillatory motion to a linear motion through a ratchet-type configuration. Figure 3 illustrates the basic unit where there are two comb­ like arrays on either side. These generate the actual force. They are connected to a cross piece that converts oscillatory motion in concert with a spring to a pulsatile linear motion of the vertical shaft. This connects to some gears which do a mechanical transformation. Figure 2. Functional MEMS Micromachines Attached to Sensing Bioelectrodes. The gears have features as small as 50 microns, less than the size of a period on a printed page. (Courtesy of Dr. J. Muthuswamy, Bioengineering Department, ASU) , fon• 11, ~--- ...~ Figure 3. Schematic Diagram of a MEMS Motor Complete With a Method of Converting Oscillatory Motion to Linear Motion. (Courtesy of Dr. J. Muthuswamy, Bioengineering Department, ASU) UNCLASSIFIED/ {FOR OFFICIO! !Pfli ODIi.¥ 5
Check the original PDF
The Neural Probe chip enables precise bi-directional positioning of the microelectrodes in the brain with a step resolution in the order of 8.8 µm. The thermal microactuators allow for a movement of the microelectrodes of up to 5 mm in either direction making it suitable for positioning microelectrodes in deep structures of a rodent brain. The rest of the mechanism converts an oscillatory motion to a linear motion through a ratchet-type configuration. Figure 3 illustrates the basic unit where there are two comb-like arrays on either side. These generate the actual force. They are connected to a cross piece that converts oscillatory motion in concert with a spring to a pulsatile linear motion of the vertical shaft. This connects to some gears which do a mechanical transformation. Figure 2. Functional MEMS Micromachines Attached to Sensing Bioelectrodes. The gears have features as small as 50 microns, less than the size of a period on a printed page. (Courtesy of Dr. J. Muthuswamy, Bioengineering Department, ASU) Figure 3. Schematic Diagram of a MEMS Motor Complete With a Method of Converting Oscillatory Motion to Linear Motion. (Courtesy of Dr. J. Muthuswamy, Bioengineering Department, ASU)

View the document record ↗ · Physical page 11, counting the cover.

EXCERPT 48 · PHYSICAL PAGE 12

D136, physical page 12: Figures 4 and 5, BioMEMS motor principle and gears, and fluidic BioMEMS

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ Figure 4 illustrates the basic physics where the force is generated. A voltage V, is applied to the horizontal sliding shaft. There arises an electrical field (shown as the curved arrow) that tends to pull the shaft into the cavity between the two outer combs. This is the basic motive force of the device. The force generated by each comb is very small so there are constructed many similar structures that form a comb-array. All of the forces act in parallel. (1) V (3) Figure 4. Illustration of the Basic Physical Principle of the BioMEMS Motor (Muthuswamy et al.) The device is fabricated by using Sandia's Ultraplanar Multi-level MEMS Technology (SUMMiTV) process, a 5-layer polysilicon micromachining technology. The layers are chemically sensitive to different processes and can be selectively removed by etching with different reagents. For example silicon can be removed using an etchant which preferentially removes silicon only along certain crystalline planes. Other layers can be undermined through the use of acids. The components of the micromachine are patterned on the silicon using photoresist masks. A mask is a covering which prevents parts of the silicon from being etched away. Figure 5 gives an idea of the sophistication of this MEMS fabrication technique. The end result is that the long rod at the right of the picture in Figure 3 moves up and down with a speed of about 1-2 mm per second. The speed can be adjusted through the number of teeth designed on the reduction gears. Single unit recordings were obtained from the somatosensory cortex of adult rats over a period of three days demonstrating the feasibility of th is technology. This device has been implanted in rats and its development supported by the neuroprostheses program of the US National Institutes of Health. Fluidic BioMEMS The application of microscale fabrication techniques has allowed the manipulation of very small volumes of fluids on the nanoliter and even picoliter scales. This allows 6 UNCLASSIFIED/ (FOR OFFICIO! P!Sli Qllk¥ Figure s. Close-Up Views of the Micro-Motor Gears (Sandia National Labs)
Check the original PDF
Figure 4 illustrates the basic physics where the force is generated. A voltage V, is applied to the horizontal sliding shaft. There arises an electrical field (shown as the curved arrow) that tends to pull the shaft into the cavity between the two outer combs. This is the basic motive force of the device. The force generated by each comb is very small so there are constructed many similar structures that form a comb-array. All of the forces act in parallel. [Figure 4 labels: (1); (2); (3); d; y; x; V] Figure 4. Illustration of the Basic Physical Principle of the BioMEMS Motor (Muthuswamy et al.) The device is fabricated by using Sandia's Ultraplanar Multi-level MEMS Technology (SUMMiT V) process, a 5-layer polysilicon micromachining technology. The layers are chemically sensitive to different processes and can be selectively removed by etching with different reagents. For example silicon can be removed using an etchant which preferentially removes silicon only along certain crystalline planes. Other layers can be undermined through the use of acids. The components of the micromachine are patterned on the silicon using photoresist masks. A mask is a covering which prevents parts of the silicon from being etched away. Figure 5 gives an idea of the sophistication of this MEMS fabrication technique. Figure 5. Close-Up Views of the Micro-Motor Gears (Sandia National Labs) The end result is that the long rod at the right of the picture in Figure 3 moves up and down with a speed of about 1-2 mm per second. The speed can be adjusted through the number of teeth designed on the reduction gears. Single unit recordings were obtained from the somatosensory cortex of adult rats over a period of three days demonstrating the feasibility of this technology. This device has been implanted in rats and its development supported by the neuroprostheses program of the US National Institutes of Health. Fluidic BioMEMS The application of microscale fabrication techniques has allowed the manipulation of very small volumes of fluids on the nanoliter and even picoliter scales. This allows

View the document record ↗ · Physical page 12, counting the cover.

EXCERPT 49 · PHYSICAL PAGE 13

D136, physical page 13: fluidic BioMEMS and drug delivery pumps

UNCLASSIFIED/ /P'OR: OP'Pl@IAL WS& 0NI.¥ chemical processes such as separations, reactions, and analysis to be conducted with very small amounts of sample. According to a forecast by the Nexus Task Force, the market for BioMEMS is expected to reach $18 Billion in 2005. The commercial success of these devices and the technical potential of other BioMEMS has driven research in a number of areas. As a result, over the past few years, fluidic BioMEMS devices have become the largest and most diverse applications of MEMS devices. Fluidic BioMEMS now include: • Drug-delivering neuroprobes. • Biosensors (general). • Bioreactors. • Cell-handl ing devices. • Drug-delivery devices. • Micro-chromatography systems. • Microfluidics. • Molecular detection/handling. • Neural interface devices. • Optical/retinal sensing. • Surgical devices. • Tissue-handling devices. There are obviously application overlaps within these devices and some are integrated with others to create system-level or multi-sensing devices. Applications run the gamut of the imagination includ ing identification of bacterial or viral agents, drug testing, home testing, environmental safety and security, and drug-delivery technologies. DRUG-DELIVERY PUMPS Drug delivery to the human body for medical therapeutic purposes has long been by swallowing substances or by injection. However this approach creates rapid rises and falls in drug concentration in the blood stream because the dose is typically introduced all at one time. The blood titer of a drug may thus peak at undesirably high levels in an effort to sustain the drug action over a longer period of time. Treatment of many medical conditions, such as cancer by chemotherapeutic drugs would best be accomplished by a steady and long sustained infusion of the drug into the blood. This would keep the tumor-fighting drug at some optimal concentration and so make it maximally effective. High levels of chemotherapeutic drug levels in the blood are toxic and levels that are below some threshold are ineffective. UNCLASSIFIED/ (FOR OFFICIO! P!Sli QDII.¥ 7
Check the original PDF
chemical processes such as separations, reactions, and analysis to be conducted with very small amounts of sample. According to a forecast by the Nexus Task Force, the market for BioMEMS is expected to reach $18 Billion in 2005. The commercial success of these devices and the technical potential of other BioMEMS has driven research in a number of areas. As a result, over the past few years, fluidic BioMEMS devices have become the largest and most diverse applications of MEMS devices. Fluidic BioMEMS now include: • Drug-delivering neuroprobes. • Biosensors (general). • Bioreactors. • Cell-handling devices. • Drug-delivery devices. • Micro-chromatography systems. • Microfluidics. • Molecular detection/handling. • Neural interface devices. • Optical/retinal sensing. • Surgical devices. • Tissue-handling devices. There are obviously application overlaps within these devices and some are integrated with others to create system-level or multi-sensing devices. Applications run the gamut of the imagination including identification of bacterial or viral agents, drug testing, home testing, environmental safety and security, and drug-delivery technologies. DRUG-DELIVERY PUMPS Drug delivery to the human body for medical therapeutic purposes has long been by swallowing substances or by injection. However this approach creates rapid rises and falls in drug concentration in the blood stream because the dose is typically introduced all at one time. The blood titer of a drug may thus peak at undesirably high levels in an effort to sustain the drug action over a longer period of time. Treatment of many medical conditions, such as cancer by chemotherapeutic drugs would best be accomplished by a steady and long sustained infusion of the drug into the blood. This would keep the tumor-fighting drug at some optimal concentration and so make it maximally effective. High levels of chemotherapeutic drug levels in the blood are toxic and levels that are below some threshold are ineffective.

View the document record ↗ · Physical page 13, counting the cover.

EXCERPT 50 · PHYSICAL PAGE 14

D136, physical page 14: Figure 6, MEMS insulin pump, and diabetes

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ Methods of creating a more sustained blood concentration of a given drug are desirable to increase drug effectiveness. Similarly there are other medical applications for controlled-release drug-delivery systems, such as that for insulin, where it is desirable to maintain a more sustained dose over a period of hours. There has been the application of MEMS technologies in the creation of better ways to deliver drugs to the human body by way of small implantable reservoirs that can slowly release their drug over a prolonged period of time. Figure 6 shows a MEMS-based insulin-delive ry pump for the treatment of diabetes. This is perhaps one of the largest applications of BioMEMS in medicine. Subcutaneous drug delivery Debiotech p iezoelec ric in sulin pump S itzerland http://lllww.tfebiotech.com/dobiotoch.h • MEMS technology using Si and glass biocompatibility • Precise control of nl volumes • Prevent under/overdosing and detect occlusions, other problems • Small size: 114th the size of existing monitors • Proprietary hermetic packaging • In he U.S. alone, 60 million people are affec e by diabe es • 15% of worldwide heal h spending goes award rea ing diabe es. • 450,000 people now wear ransportable insulin pumps worldwide. sources: Debiotech ebsite· Advanced Packaging Figure 6. An Insulin MEMS Pump. An implantable drug-delivery device. Diabetes is a disorder in which glucose (blood sugar) is not proper ly taken into the cells of the body. This process is norma lly mediated by the hormone insulin, which is produced by the islet cells of the pancreas. Insulin circulates in the blood to actuate a receptor on tissue cells that causes them to uptake glucose from the blood stream. If there is too little insulin (as in Type 1 diabetes) the cells will not uptake glucose from the blood, the cells will starve, and blood sugar levels become too high from unabsorbed glucose. Alternat ively, cells may not respond properly to normal insulin levels (as in Type 2 diabetes) and require artificially higher levels of insulin to uptake glucose. This is called insulin resista nce. In either case, blood insulin levels can be increased by using insulin injection devices. Brittle diabetes is a conditio n where blood glucose levels fluctuate wildly with eating or fasting causing hyperglycem ia (too high a blood glucose-more than about 100 mg percent) or too low (hypoglycemia-less than about 60 mg percent). Britt le diabetics UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ 8
Check the original PDF
Methods of creating a more sustained blood concentration of a given drug are desirable to increase drug effectiveness. Similarly there are other medical applications for controlled-release drug-delivery systems, such as that for insulin, where it is desirable to maintain a more sustained dose over a period of hours. There has been the application of MEMS technologies in the creation of better ways to deliver drugs to the human body by way of small implantable reservoirs that can slowly release their drug over a prolonged period of time. Figure 6 shows a MEMS-based insulin-delivery pump for the treatment of diabetes. This is perhaps one of the largest applications of BioMEMS in medicine. [Figure 6 content: Subcutaneous drug delivery; Debiotech piezoelectric insulin pump, Switzerland; http://www.debiotech.com/debiotech.html; • MEMS technology using Si and glass biocompatibility • Precise control of nL volumes • Prevent under/overdosing and detect occlusions, other problems • Small size: 1/4th the size of existing monitors • Proprietary hermetic packaging • In the U.S. alone, 60 million people are affected by diabetes • 15% of worldwide health spending goes toward treating diabetes. • 450,000 people now wear transportable insulin pumps worldwide. sources: Debiotech website; Advanced Packaging] Figure 6. An Insulin MEMS Pump. An implantable drug-delivery device. Diabetes is a disorder in which glucose (blood sugar) is not properly taken into the cells of the body. This process is normally mediated by the hormone insulin, which is produced by the islet cells of the pancreas. Insulin circulates in the blood to actuate a receptor on tissue cells that causes them to uptake glucose from the blood stream. If there is too little insulin (as in Type 1 diabetes) the cells will not uptake glucose from the blood, the cells will starve, and blood sugar levels become too high from unabsorbed glucose. Alternatively, cells may not respond properly to normal insulin levels (as in Type 2 diabetes) and require artificially higher levels of insulin to uptake glucose. This is called insulin resistance. In either case, blood insulin levels can be increased by using insulin injection devices. Brittle diabetes is a condition where blood glucose levels fluctuate wildly with eating or fasting causing hyperglycemia (too high a blood glucose—more than about 100 mg percent) or too low (hypoglycemia—less than about 60 mg percent). Brittle diabetics

View the document record ↗ · Physical page 14, counting the cover.

EXCERPT 51 · PHYSICAL PAGE 15

D136, physical page 15: insulin pumps and what a biosensor is

UNCLASSIFIED/ /P'OR: OP'Pl@IAL WS& 0NI.¥ have a significant problem in controlling their blood sugar and sometimes insulin doses are not adjusted finely enough or frequently enough to maintain the blood glucose at healthy levels. This form of diabetes is responsible for fainting (ketoacidosis) and other serious symptoms such as poor blood circulation to the limbs. Poor circulation can result in diabetic ulcers and may sometimes necessitate amputation of the limb. Insulin pumps are often worn by brittle diabetics because a slow infusion of insulin works better in stabilizing blood glucose levels rather than periodic injections. A belt­ worn insulin-delivery system looks something like an old-style audio player. These systems are typically controlled by a small screw-type pump powered by batteries. The reservoir carries several milliliters of insulin for dispensing over an extended period of time. The injection needle is connected (underneath the clothes) to a catheter and then to the pump. The systems are reasonably effective but are cumbersome and require the needle to continuously reside subcutaneously in the abdomen. A MEMS implanted insulin pump is a less cumbersome and perhaps more convenient means of slowly infusing insulin at a programmed rate. The implanted device is refilled periodically by introducing a needle through the skin and tissue to a septum in the device. The MEMS insulin pump shown in Figure 6 is surgically placed under the skin. It has a rubber septum on the top for filling with insulin. This implementation has a piezoelectric element that moves in response to electrical charge. When actuated by a timer the element oscillates, creating a pressure inside the device that dispenses insulin. The device is programmable for dispensing at various rates. Although the implantable MEMS pump was developed for diabetes, the pump has application to the slow measured delivery of many other drugs including 5-fluoruracil used for cancer therapy and theophyllne for treatment of asthma. What is a Biosensor? A primary application of BioMEMS is in the creation of sensors for blood chemistry and other biophysical parameters of the human body. We can define a Biosensor as: • A sensor whose application is primarily in the measurement of quantities within a biological system, such as chemical, electrical, and physical parameters. • A sensor incorporating a biological component (enzymes, living cells, antibodies) typically used to measure chemical concentration. This definition does not require that the sensor be deployed within a biological system. The two definit ions which are somewhat different have their origin with different influential investigators who wrote textbooks in the early days of this field. The latter definition is prevalent in Europe. A biosensor is normally constructed by immobilizing a biologically active mater ial (such as an enzyme) onto an electrical sensor that measures a fundamental physical quantity like electrical current, voltage, mechanical strain, temperature, or frequency. The specific sensor material is chosen because it reacts to a desired measurand (such as UNCLASSIFIED/ {FOR OFFICIO! !PEii ODIi.¥ 9
Check the original PDF
have a significant problem in controlling their blood sugar and sometimes insulin doses are not adjusted finely enough or frequently enough to maintain the blood glucose at healthy levels. This form of diabetes is responsible for fainting (ketoacidosis) and other serious symptoms such as poor blood circulation to the limbs. Poor circulation can result in diabetic ulcers and may sometimes necessitate amputation of the limb. Insulin pumps are often worn by brittle diabetics because a slow infusion of insulin works better in stabilizing blood glucose levels rather than periodic injections. A belt-worn insulin-delivery system looks something like an old-style audio player. These systems are typically controlled by a small screw-type pump powered by batteries. The reservoir carries several milliliters of insulin for dispensing over an extended period of time. The injection needle is connected (underneath the clothes) to a catheter and then to the pump. The systems are reasonably effective but are cumbersome and require the needle to continuously reside subcutaneously in the abdomen. A MEMS implanted insulin pump is a less cumbersome and perhaps more convenient means of slowly infusing insulin at a programmed rate. The implanted device is refilled periodically by introducing a needle through the skin and tissue to a septum in the device. The MEMS insulin pump shown in Figure 6 is surgically placed under the skin. It has a rubber septum on the top for filling with insulin. This implementation has a piezoelectric element that moves in response to electrical charge. When actuated by a timer the element oscillates, creating a pressure inside the device that dispenses insulin. The device is programmable for dispensing at various rates. Although the implantable MEMS pump was developed for diabetes, the pump has application to the slow measured delivery of many other drugs including 5-fluoruracil used for cancer therapy and theophylline for treatment of asthma. What is a Biosensor? A primary application of BioMEMS is in the creation of sensors for blood chemistry and other biophysical parameters of the human body. We can define a Biosensor as: • A sensor whose application is primarily in the measurement of quantities within a biological system, such as chemical, electrical, and physical parameters. • A sensor incorporating a biological component (enzymes, living cells, antibodies) typically used to measure chemical concentration. This definition does not require that the sensor be deployed within a biological system. The two definitions which are somewhat different have their origin with different influential investigators who wrote textbooks in the early days of this field. The latter definition is prevalent in Europe. A biosensor is normally constructed by immobilizing a biologically active material (such as an enzyme) onto an electrical sensor that measures a fundamental physical quantity like electrical current, voltage, mechanical strain, temperature, or frequency. The specific sensor material is chosen because it reacts to a desired measurand (such as

View the document record ↗ · Physical page 15, counting the cover.

EXCERPT 52 · PHYSICAL PAGE 16

D136, physical page 16: implantable BioMEMS sensors

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ concentration of glucose) and thus causes a change in one of these fundamental quantities . Electrical sensors can be inherently small and so we have a combination device with biology and electrical sensing in a small and compact form. When compared to much larger bench top machines, microscale configurations of sensors usually have a superior performance because they are less prone to various interferences such as power-line noise and they have much shorter diffusion distances for sensed molecules. Some physical quantities such as micro-degrees of temperature change are much easier to measure over small distances. BioMEMS Implantable Sensors Biosensors placed inside the body, or in-vivo, measure biological parameters such as blood pH, oxygen, carbon dioxide, and blood glucose. (Blood pH is a measure of the acidity of the blood.) These parameters are the most important in medicine since these are all independent blood chemistries that give a moment-to-moment insight into the physiological state of a living being. Since the early days of the space program NASA has been interested in ways of noninvas ively monitoring these blood parameters in astronauts for the instant assessment of their physiological condition. Until recently, blood withdrawal was the only accurate and reliable way to obtain such information. Indwelling sensors that use needle penetrations are now available but still have trouble with accuracy and longevity . The military has also been inte rested in the assessment of the state of readiness of a soldier which is reflected in his blood chemistry. An exhausted solider will show a highly acidic blood pH (less than about 7.3). Remote electronic readout of biosensor informat ion of a soldier to a central command center is presently the stuff of science fiction movies but reflects real desires of the military. Figure 7 shows a photo of a pH sensor (which measures concentration of hydrogen ions). It is designed as a needle for tissue insertion or placement at the end of a catheter for introduction into the blood stream. The pointed tip is inserted into the medium to be measured, and t he electrical signal and power supply are connected to the device at the gold film contacts at the base. UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ 10
Check the original PDF
concentration of glucose) and thus causes a change in one of these fundamental quantities. Electrical sensors can be inherently small and so we have a combination device with biology and electrical sensing in a small and compact form. When compared to much larger bench top machines, microscale configurations of sensors usually have a superior performance because they are less prone to various interferences such as power-line noise and they have much shorter diffusion distances for sensed molecules. Some physical quantities such as micro-degrees of temperature change are much easier to measure over small distances. BioMEMS Implantable Sensors Biosensors placed inside the body, or in-vivo, measure biological parameters such as blood pH, oxygen, carbon dioxide, and blood glucose. (Blood pH is a measure of the acidity of the blood.) These parameters are the most important in medicine since these are all independent blood chemistries that give a moment-to-moment insight into the physiological state of a living being. Since the early days of the space program NASA has been interested in ways of noninvasively monitoring these blood parameters in astronauts for the instant assessment of their physiological condition. Until recently, blood withdrawal was the only accurate and reliable way to obtain such information. Indwelling sensors that use needle penetrations are now available but still have trouble with accuracy and longevity. The military has also been interested in the assessment of the state of readiness of a soldier which is reflected in his blood chemistry. An exhausted solider will show a highly acidic blood pH (less than about 7.3). Remote electronic readout of biosensor information of a soldier to a central command center is presently the stuff of science fiction movies but reflects real desires of the military. Figure 7 shows a photo of a pH sensor (which measures concentration of hydrogen ions). It is designed as a needle for tissue insertion or placement at the end of a catheter for introduction into the blood stream. The pointed tip is inserted into the medium to be measured, and the electrical signal and power supply are connected to the device at the gold film contacts at the base.

View the document record ↗ · Physical page 16, counting the cover.

EXCERPT 53 · PHYSICAL PAGE 17

D136, physical page 17: Figure 7, ISFET pH sensor

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ Vgs 1: reference 2: gate oxide 3: insulating resin b) 4: channnel S: source D: drain B: bulk Vgs a) V r Vdr MOSFET ISFET Figure 7. An ISFET (Ion Sensitive Field Effect Transistor) Needle-Type pH Sensor for Monitoring Tissue Physiologic Status (http://www .ee.seikei .ac.jp/ ~seiichi/lecture/Biomedical/09/09 -biosensor .html) The sensor element is an ion sensitive field effect transistor (ISFET). This device is micromachined from silicon by using standard semiconductor photolithography processes. The actual active sensor surface is near the tip of the device where there is a thin film of silicon nitride covering the gate region of the transistor. The gate is sensit ive to very small changes in electric field, and these in turn cause relatively large changes (or gain) in the current flow through the transistor. At the center in Figure 7 is a standard transistor diagram showing the gate and its relation to the other contacts. On the right is shown the pH sensitive ISFET system that measures an electric field change across the nitride membrane. The membrane is placed directly in contact with the liquid to be measured. It is not known the exact process that occurs at the membrane that gives rise to electric field shifts on the gate. Presumably hydrogen ions reversibly adsorb onto the interface between the nitride membrane and the solution causing local electric field changes on the gate. This device is not meant for permanent implantation but rather short term applications in research or medical surgery where the sensor is used over just a few hours. Proteins and other biological molecules adhere to the gate region of the ISFET and cause a slow UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ 11
Check the original PDF
[Figure 7 labels: 1: reference; 2: gate oxide; 3: insulating resin; 4: channel; S: source; D: drain; B: bulk; a); b); Vgs; Vdr; solution; MOSFET; ISFET] Figure 7. An ISFET (Ion Sensitive Field Effect Transistor) Needle-Type pH Sensor for Monitoring Tissue Physiologic Status (http://www.ee.seikei.ac.jp/~seiichi/lecture/Biomedical/09/09-biosensor.html) The sensor element is an ion sensitive field effect transistor (ISFET). This device is micromachined from silicon by using standard semiconductor photolithography processes. The actual active sensor surface is near the tip of the device where there is a thin film of silicon nitride covering the gate region of the transistor. The gate is sensitive to very small changes in electric field, and these in turn cause relatively large changes (or gain) in the current flow through the transistor. At the center in Figure 7 is a standard transistor diagram showing the gate and its relation to the other contacts. On the right is shown the pH sensitive ISFET system that measures an electric field change across the nitride membrane. The membrane is placed directly in contact with the liquid to be measured. It is not known the exact process that occurs at the membrane that gives rise to electric field shifts on the gate. Presumably hydrogen ions reversibly adsorb onto the interface between the nitride membrane and the solution causing local electric field changes on the gate. This device is not meant for permanent implantation but rather short term applications in research or medical surgery where the sensor is used over just a few hours. Proteins and other biological molecules adhere to the gate region of the ISFET and cause a slow

View the document record ↗ · Physical page 17, counting the cover.

EXCERPT 54 · PHYSICAL PAGE 18

D136, physical page 18: Figure 8, fiber-optic oxygen sensor

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ drift and offset in the reading and so shifting the calibration. Depending on its exact construction some versions however can be effective for as much as a few days. Figure 8 shows the latest in microdevice oxygen sensors. (This particular version is not specifically a MEMS device since it is not made by photolithography and it is neit her .§lectrical nor mechanical in nature.) It represents however the trend in oxygen sensors towards optical measurement techniques that are evolving towards optical systems based on MEMS. These sensors can be implemented in small sizes with optical fibers that transmit and receive light from the sensor surface at the tip. Variations on this basic principle are used for indwelling blood oxygen catheters during surgery. fiber op cs silicone cover Figure 8. A Fiber Optical Oxygen Sensor Showing Two Optical Fibers Mated to Plastic Prisms That are Coated With an Oxygen-Sensor Coating, Usually a Fluorescent Ruthenium Compound (http://www.imtek.de/content/projekte _en. php?ls= 11) The oxygen sensors respond to changes in absorption of oxygen into the special coating at the tip, or in some versions, they respond to fluorescence of a thin oxygen-sensitive coating placed on the prism surface. The secret to good performance lies in the proprietary selection of the specific chemical species selected for the coating. Blue light is usually transmitted down the optical fiber and the coating glows orange in proportion to the amount of oxygen present. The light from the glow is conducted back toward the supporting instrumentation system. The intensity of the orange light then indicates oxygen levels in the solution. The particular sensor shown in Figure 8 uses two optical fibers. The one on the left side is not sensitive to oxygen, but rather acts as a reference system that is used to compensate for changes temperature, ambient light, and other system variables. UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ 12
Check the original PDF
drift and offset in the reading and so shifting the calibration. Depending on its exact construction some versions however can be effective for as much as a few days. Figure 8 shows the latest in microdevice oxygen sensors. (This particular version is not specifically a MEMS device since it is not made by photolithography and it is neither electrical nor mechanical in nature.) It represents however the trend in oxygen sensors towards optical measurement techniques that are evolving towards optical systems based on MEMS. These sensors can be implemented in small sizes with optical fibers that transmit and receive light from the sensor surface at the tip. Variations on this basic principle are used for indwelling blood oxygen catheters during surgery. [Figure 8 labels: fiber optics; silicone cover; prism; silicone carrier] Figure 8. A Fiber Optical Oxygen Sensor Showing Two Optical Fibers Mated to Plastic Prisms That are Coated With an Oxygen-Sensor Coating, Usually a Fluorescent Ruthenium Compound (http://www.imtek.de/content/projekte_en.php?ls=11) The oxygen sensors respond to changes in absorption of oxygen into the special coating at the tip, or in some versions, they respond to fluorescence of a thin oxygen-sensitive coating placed on the prism surface. The secret to good performance lies in the proprietary selection of the specific chemical species selected for the coating. Blue light is usually transmitted down the optical fiber and the coating glows orange in proportion to the amount of oxygen present. The light from the glow is conducted back toward the supporting instrumentation system. The intensity of the orange light then indicates oxygen levels in the solution. The particular sensor shown in Figure 8 uses two optical fibers. The one on the left side is not sensitive to oxygen, but rather acts as a reference system that is used to compensate for changes temperature, ambient light, and other system variables.

View the document record ↗ · Physical page 18, counting the cover.

EXCERPT 55 · PHYSICAL PAGE 19

D136, physical page 19: MEMS blood glucose sensors and Figure 9

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 8NI.¥ So far, despite decades of work, no continuous monitoring sensor that is self contained and implantable has been successful for long term usage. The human body is an exceptionally hostile environment for foreign materials. Even our most advanced biosensors fail over a period of days or weeks if continuously exposed to the body environment. This failure is mostly due to the sensor chemistry wearing out in one way or another or attack of the sensor interface by the body's immune system. Failure is not generally attr ibuted to the materials of which the sensor is made. MEMS Blood Glucose Sensors Diabetes is an enormous world problem. A significant fraction of the annual world health care expenditures can be traced back to diabetes, and its cousin, obesity. Measurement of blood glucose on a regular basis, usually 3-4 times a day, allows a diabetic to regulate his diet and insulin dose to achieve normal glucose levels. Perhaps one of the most needed biosensors is that for an in-vivo blood glucose sensor. These could be used to automatically control of the output of an insulin-delivery pump. This would constitute a major improvement in the treatment of diabetes by automatically using blood glucose concentration feedback to stabilize the blood glucose levels with the exact level of needed insulin. This kind of system is sometimes called an artific ial endocrine pancreas since it mimics the normal function of the pancreas in regulating insulin release. There are several attempts at using MEMS devices to produce indwelling glucose sensors. These are presently on the market, but currently the sensors have relatively short lifetimes, are disposable, and require replacement every few days. Figure 9 shows this basic idea. An implantable sensor produces an electrical output that reports the blood glucose concentration. Its signal is transmitted to a receiver and then processed by a computer to drive a belt-worn pump. The creation of such a sensor has been a daunting problem from more than 30 years. The most recent attempts have been in the use of micromachining to produce optical devices of very small size and to produce wireless transmitting electrochemical sensor devices small enough to be injected into the body• Figure 9. Control of an Insulin-Delivery System by an Implantable Glucose Sensor (Medtronic Inc.) Coincident with the development of sensors has been the need to develop very small wireless telemetry systems that transmit the sensor data to outside the body. UNCLASSIFIED/ {FOR OFFICIO! !Pfli ODIi.¥ 13
Check the original PDF
So far, despite decades of work, no continuous monitoring sensor that is self contained and implantable has been successful for long term usage. The human body is an exceptionally hostile environment for foreign materials. Even our most advanced biosensors fail over a period of days or weeks if continuously exposed to the body environment. This failure is mostly due to the sensor chemistry wearing out in one way or another or attack of the sensor interface by the body's immune system. Failure is not generally attributed to the materials of which the sensor is made. MEMS Blood Glucose Sensors Diabetes is an enormous world problem. A significant fraction of the annual world health care expenditures can be traced back to diabetes, and its cousin, obesity. Measurement of blood glucose on a regular basis, usually 3-4 times a day, allows a diabetic to regulate his diet and insulin dose to achieve normal glucose levels. Perhaps one of the most needed biosensors is that for an in-vivo blood glucose sensor. These could be used to automatically control of the output of an insulin-delivery pump. This would constitute a major improvement in the treatment of diabetes by automatically using blood glucose concentration feedback to stabilize the blood glucose levels with the exact level of needed insulin. This kind of system is sometimes called an artificial endocrine pancreas since it mimics the normal function of the pancreas in regulating insulin release. There are several attempts at using MEMS devices to produce indwelling glucose sensors. These are presently on the market, but currently the sensors have relatively short lifetimes, are disposable, and require replacement every few days. Figure 9 shows this basic idea. An implantable sensor produces an electrical output that reports the blood glucose concentration. Its signal is transmitted to a receiver and then processed by a computer to drive a belt-worn pump. The creation of such a sensor has been a daunting problem from more than 30 years. The most recent attempts have been in the use of micromachining to produce optical devices of very small size and to produce wireless transmitting electrochemical sensor devices small enough to be injected into the body. [Figure 9 labels: 1 Glucose sensor; 2; 3; Insulin pump] Figure 9. Control of an Insulin-Delivery System by an Implantable Glucose Sensor (Medtronic Inc.) Coincident with the development of sensors has been the need to develop very small wireless telemetry systems that transmit the sensor data to outside the body.

View the document record ↗ · Physical page 19, counting the cover.

EXCERPT 56 · PHYSICAL PAGE 20

D136, physical page 20: commercial glucose sensors, enzymatic biosensors and Figure 10

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ COMMERCIAL BLOOD GLUCOSE SENSORS The present method of blood glucose monitoring depends on a needle puncture of the skin to withdraw a drop of blood to place on a color changing test strip. The test strip is read by a small handheld reader. Glucose test strips do not have to necessarily be small, but by making the sensor very small the amount of blood required for the test is reduced. The sensors often are made by techniques of photolithography or in some cases by microscale screen printing in order to achieve reproducibility. The skin-puncture test is painful and time consuming, and thus noninvasiveness is the key desired characteristic of glucose sensors. Research is being directed at a noninvas ive glucose sensor that is accurate enough to work external to the body and through the skin. Short term (a few days) wearable needle glucose sensors are available from major companies like Medtronic Inc. but fall short of the convenience of a noninvasive sensor. ENZYME-BASED BIOSENSORS The key component in most biosensors is a reactive chemistry on the sensor surface. The sensor chemistry is chosen to give it specificity to only one analyte (such as glucose). The concentration of the analyte is determined by a sensor that can directly measure the analyte reaction products reacting with the sensor surface. For example sensor chemistries to measure glucose are often based on glucose oxidase enzyme which promotes a chemical reaction at the sensor surface. Glucose oxidase enzyme complex structure is seen in Figure 10. Glucose oxidase catalyzes the reaction: glucose + 0 2 (glucose oxidase) ➔ gluconolactone + H2O2 + heat (79 kJ/mole) This reaction of glucose with oxygen (from the air) occurs in the presence of glucose oxidase enzyme. The enzyme itself is a catalyst to the reaction and so is not consumed. Rather it presents favorable conditions and ability to transfer electrons on its molecular structure for glucose and oxygen to come together to react. Figure 10 shows the enzyme structure. Typically in a sensor the enzyme is a large molecule and can be trapped in a porous gel and thus is not able to diffuse away from the sensor surface. Glucose and oxygen, being small molecules, can diffuse through the gel to the enzyme whereby the reaction occurs and the reaction products will diffuse away. The enzyme is unconsumed and the reaction process is continuous as long as glucose is present. UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ Figure 10. Glucose Oxidase Enzymes Like Glucose Oxidase are Large Folded Molecules That Act as Catalysts for a Chemical Reaction (http ://www. innovations- report .de/bilder _neu/17279_gluc.jpg) 14
Check the original PDF
COMMERCIAL BLOOD GLUCOSE SENSORS The present method of blood glucose monitoring depends on a needle puncture of the skin to withdraw a drop of blood to place on a color changing test strip. The test strip is read by a small handheld reader. Glucose test strips do not have to necessarily be small, but by making the sensor very small the amount of blood required for the test is reduced. The sensors often are made by techniques of photolithography or in some cases by microscale screen printing in order to achieve reproducibility. The skin-puncture test is painful and time consuming, and thus noninvasiveness is the key desired characteristic of glucose sensors. Research is being directed at a noninvasive glucose sensor that is accurate enough to work external to the body and through the skin. Short term (a few days) wearable needle glucose sensors are available from major companies like Medtronic Inc. but fall short of the convenience of a noninvasive sensor. ENZYME-BASED BIOSENSORS The key component in most biosensors is a reactive chemistry on the sensor surface. The sensor chemistry is chosen to give it specificity to only one analyte (such as glucose). The concentration of the analyte is determined by a sensor that can directly measure the analyte reaction products reacting with the sensor surface. For example sensor chemistries to measure glucose are often based on glucose oxidase enzyme which promotes a chemical reaction at the sensor surface. Glucose oxidase enzyme complex structure is seen in Figure 10. Glucose oxidase catalyzes the reaction: glucose + O₂ (glucose oxidase) → gluconolactone + H₂O₂ + heat (79 kJ/mole) This reaction of glucose with oxygen (from the air) occurs in the presence of glucose oxidase enzyme. The enzyme itself is a catalyst to the reaction and so is not consumed. Rather it presents favorable conditions and ability to transfer electrons on its molecular structure for glucose and oxygen to come together to react. Figure 10 shows the enzyme structure. Typically in a sensor the enzyme is a large molecule and can be trapped in a porous gel and thus is not able to diffuse away from the sensor surface. Glucose and oxygen, being small molecules, can diffuse through the gel to the enzyme whereby the reaction occurs and the reaction products will diffuse away. The enzyme is unconsumed and the reaction process is continuous as long as glucose is present. Figure 10. Glucose Oxidase. Enzymes Like Glucose Oxidase are Large Folded Molecules That Act as Catalysts for a Chemical Reaction (http://www.innovations-report.de/bilder_neu/17279_gluc.jpg)

View the document record ↗ · Physical page 20, counting the cover.

EXCERPT 57 · PHYSICAL PAGE 21

D136, physical page 21: Figure 11, experimental glucose sensor, and thermopile sensors

UNCLASSIFIED/ /P'OR: OP'Pl@IAL WS& 0NI.¥ An enzyme-gel is applied in a thin layer over a electrically biased metal electrode. An electrical current flows through the electrode when the hydrogen peroxide produced by the glucose reaction is decomposed and causes an electrical current to flow. If there is a fixed concentrat ion of glucose present, a corresponding amount of peroxide will be produced, and this can be measured by the electrical current flow. The amount of peroxide measured is an indicator of the glucose concentration. The actual amount of analyte consumed by a small BioMEMS sensor is exceedingly small and has no significant effect on the local concentration. Figure 11 shows a MEMS implementation of a blood glucose sensor using this kind of approach (Advanced Biosensors Inc). The fine needle geometry is generally meant for insertion into tissue. This device is comprised of multiple independent small sensors and is actually a system of components that adds signal processing and interface electronics to allow its communication with insulin pumps for automated delivery of insulin based on patient need. Adva nced BioSe nsors blood glucose sensor - Flip chip asse mbly AS ICs , power sources and circui componen s Sepa ra e sensors, moun wi h electrical connec ions, add he bioco mpa ible polymer, asse mble he sensor pa ch. Th e sensor base d on glucose oxidase reaction wi h blood plasma from capillaries in h e dermis. - b iochemical coa ing - sensor in place 3 - 7 days - Dock ing par for elec ronics asse mbly wi h amplifier, ADC , wireless transceiver, power source - e ncryp ed digi al da a to wristwa ch-sized morn or/reco rder module In fu ure combine the CG S wi h an insulin pump long x 200 u Ide o produce a close d-loop sys em-a n artificial pancreas . . • - ' • •· -~-s . . -• - - - 2- Figure 11. An Experimental MEMS Blood Glucose Sensor Glucose sensors based on electrical measurement of hydrogen peroxide products have been found to have the significant problem of a drifting baseline over time. It is difficult to maintain calibration of the sensors, and the electrode is affected by proteins and other substances in the blood stream. Although this sensing approach has had some success, its longevity in the body is much less than desired; sensors based on this approach decay alter a few days of use. THERMOPILE IMPLANTABLE GLUCOSE SENSORS Towe et al. at Arizona State University have been working on an improved approach to blood glucose sensing. It depends on the fact that the glucose oxidase reaction generates a small amount of heat as indicated in the above chemical reaction. The UNCLASSIFIED/ (EAR OFFICIO! !Pfli 0111.¥ 15
Check the original PDF
An enzyme-gel is applied in a thin layer over a electrically biased metal electrode. An electrical current flows through the electrode when the hydrogen peroxide produced by the glucose reaction is decomposed and causes an electrical current to flow. If there is a fixed concentration of glucose present, a corresponding amount of peroxide will be produced, and this can be measured by the electrical current flow. The amount of peroxide measured is an indicator of the glucose concentration. The actual amount of analyte consumed by a small BioMEMS sensor is exceedingly small and has no significant effect on the local concentration. Figure 11 shows a MEMS implementation of a blood glucose sensor using this kind of approach (Advanced Biosensors Inc). The fine needle geometry is generally meant for insertion into tissue. This device is comprised of multiple independent small sensors and is actually a system of components that adds signal processing and interface electronics to allow its communication with insulin pumps for automated delivery of insulin based on patient need. [Figure 11 content: Advanced BioSensors blood glucose sensor – Flip chip assembly – ASICs, power sources and circuit components – Separate sensors, mount with electrical connections, add the biocompatible polymer, assemble the sensor patch. – The sensor based on glucose oxidase reaction with blood plasma from capillaries in the dermis. – biochemical coating - sensor in place 3 - 7 days – Docking port for electronics assembly with amplifier, ADC, wireless transceiver, power source – encrypted digital data to wristwatch-sized monitor/recorder module – In future combine the CGMS with an insulin pump to produce a closed-loop system—an artificial pancreas. 1 mm long x 200 um wide. Source: http://www.devicelink.com/mddi/archive/03/06/003.html] Figure 11. An Experimental MEMS Blood Glucose Sensor Glucose sensors based on electrical measurement of hydrogen peroxide products have been found to have the significant problem of a drifting baseline over time. It is difficult to maintain calibration of the sensors, and the electrode is affected by proteins and other substances in the blood stream. Although this sensing approach has had some success, its longevity in the body is much less than desired; sensors based on this approach decay after a few days of use. THERMOPILE IMPLANTABLE GLUCOSE SENSORS Towe et al. at Arizona State University have been working on an improved approach to blood glucose sensing. It depends on the fact that the glucose oxidase reaction generates a small amount of heat as indicated in the above chemical reaction. The

View the document record ↗ · Physical page 21, counting the cover.

EXCERPT 58 · PHYSICAL PAGE 22

D136, physical page 22: Figure 12, photomicrograph of the thermoelectric sensors

UNCLASSIFIED/ /P"OR: OP"P"l@IAL WSli 01'11.¥ released chemical energy warms the surrounding environment to a degree that depends on the energy released in the exothermic reaction, which is characteristic of the particular chemistry and the amount of reactants. The heating is then dependent on the glucose concentration. Figure 12 shows these devices. They are made by MEMS techniques involving the •--· processes of using patterning by exposure to light through a mask (photolithography), metal deposition by evaporation, and sputter etching. The result is the fabrication of sensors in large arrays with many identica l sensors on a single substrate. The figure is a ·---photomicrograph of a part of a wafer production run with nine identical devices. Each one of the devices is less than 1 mm in size and would be cut apart and used independently. The ·--- ·--·darker rectangular areas at the top of ·•- each device are the electrica l bonding pads where wires attach to the device to readout its electrical response. Figure 13 shows the basic process in the Figure 12_Photomicrograph 3 x 3 Array of sensor operation. The sensor is planar Thermoelectric Glucose Sensors Constructed by and composed of a layered structure Towe et al. at ASU consisting of an enzyme gel and a thermoelectric temperature sensor. Glucose from the local medium naturally diffuses to the gel and the temperature sensor underlies a thin film of enzyme gel that conta ins the glucose oxidase. A second enzyme called catalase is used to secondarily break down hydrogen peroxide produced by the first reaction. UNCLASSIFIED/ (FOR OFFICJA 1 1155 01!1.¥ 16
Check the original PDF
released chemical energy warms the surrounding environment to a degree that depends on the energy released in the exothermic reaction, which is characteristic of the particular chemistry and the amount of reactants. The heating is then dependent on the glucose concentration. Figure 12 shows these devices. They are made by MEMS techniques involving the processes of using patterning by exposure to light through a mask (photolithography), metal deposition by evaporation, and sputter etching. The result is the fabrication of sensors in large arrays with many identical sensors on a single substrate. The figure is a photomicrograph of a part of a wafer production run with nine identical devices. Each one of the devices is less than 1 mm in size and would be cut apart and used independently. The darker rectangular areas at the top of each device are the electrical bonding pads where wires attach to the device to readout its electrical response. Figure 12. Photomicrograph 3 x 3 Array of Thermoelectric Glucose Sensors Constructed by Towe et al. at ASU Figure 13 shows the basic process in the sensor operation. The sensor is planar and composed of a layered structure consisting of an enzyme gel and a thermoelectric temperature sensor. Glucose from the local medium naturally diffuses to the gel and the temperature sensor underlies a thin film of enzyme gel that contains the glucose oxidase. A second enzyme called catalase is used to secondarily break down hydrogen peroxide produced by the first reaction.

View the document record ↗ · Physical page 22, counting the cover.

EXCERPT 59 · PHYSICAL PAGE 23

D136, physical page 23: Figure 13, thermopile MEMS glucose sensor, and the Seebeck effect

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ Figure 13. A MEMS Thermopile Glucose Sensor (Towe et al., Arizona State University) Heat energy released in the gel is measured by the thermopile and is characterized in terms of kiloJoules (kJ) per mole of glucose consumed. At concentrations of glucose that are common in the blood stream, the temperature rise is very small, on t he order of a hundredth of a degree (10 millidegrees) . Measuring this temperature change in the presence of ambient body heat or room­ temperature changes of a few degrees is a daunting task, but can be done. The measurement of the small reaction temperature in the face of possible ambient temperature shifts is accomplished by the use of a differential temperature measurement system. This sensor employs what is known as the Seebeck Effect whereby dissimilar metals heated at their junction produce a voltage that is proportional to temperature. This concept is shown in Figure 14. This principle is then implemented as an array of metal junctions that when connected in series produce a higher output in order to detect smaller temperature changes. UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ 17
Check the original PDF
[Figure 13 labels: Thermoelectric Enzyme Sensor Schematic; Glucose + O2 ----------> H2O2 + Gluconic Acid + 79 kJ; H2O2 ----------> H2O + 1/2 O2 + 100 kJ; Oxygen; Gluconic Acid; Glucose; Enzyme Gel Glucose Oxidase & Catalase; Heat; Thin Mylar; Reference Junctions; Sensing Junctions; Reference Junctions; Insulation] Figure 13. A MEMS Thermopile Glucose Sensor (Towe et al., Arizona State University) Heat energy released in the gel is measured by the thermopile and is characterized in terms of kiloJoules (kJ) per mole of glucose consumed. At concentrations of glucose that are common in the blood stream, the temperature rise is very small, on the order of a hundredth of a degree (10 millidegrees). Measuring this temperature change in the presence of ambient body heat or room-temperature changes of a few degrees is a daunting task, but can be done. The measurement of the small reaction temperature in the face of possible ambient temperature shifts is accomplished by the use of a differential temperature measurement system. This sensor employs what is known as the Seebeck Effect whereby dissimilar metals heated at their junction produce a voltage that is proportional to temperature. This concept is shown in Figure 14. This principle is then implemented as an array of metal junctions that when connected in series produce a higher output in order to detect smaller temperature changes.

View the document record ↗ · Physical page 23, counting the cover.

EXCERPT 60 · PHYSICAL PAGE 24

D136, physical page 24: Figure 14, thermocouple principle, and thermopiles

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ Figure 14. Illustration of the Thermocouple Principle (Guilbeau and Towe, ASU) Figure 15 on the left panel shows a photomicrograph of a thermopile temperature sensor that is made from the metals antimony and bismuth. These metals are vacuum deposited as alternating thin films using a masking process to form horizontal lines of conductive metal. Each pair of lines has a sensing junction and a reference junction. When they are heated on their sensing junction with respect to their reference end (that is exposed to the ambient temperature), they generate a small electrical voltage. Each junction is only a few tens of microns in size so it is possible to place dozens of junctions in series in order to increase the voltage signal. Figure 15 on the right panel shows that there are two banks of thermoelectric sensors with the central common junctions supporting an enzyme gel. Thermopiles are thin film temperature sensors and are differential in nature in that they measure temperature differences, and are thus sensitive enough to detect exceedingly small temperature rises. UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ 18
Check the original PDF
[Figure 14 content: Blood Glucose Sensors for Diabetic Monitoring and Biochemical Analyses; Eric Guilbeau and Bruce Towe; Metal A; Measuring Junction; T1; T2; Reference Junction; Metal B; Seebeck Voltage; Seebeck Voltage = Thermoelectric EMF (T1 - T2); Thermoelectric EMF of Antimony/Bismuth ~ 115 µV/°C] Figure 14. Illustration of the Thermocouple Principle (Guilbeau and Towe, ASU) Figure 15 on the left panel shows a photomicrograph of a thermopile temperature sensor that is made from the metals antimony and bismuth. These metals are vacuum deposited as alternating thin films using a masking process to form horizontal lines of conductive metal. Each pair of lines has a sensing junction and a reference junction. When they are heated on their sensing junction with respect to their reference end (that is exposed to the ambient temperature), they generate a small electrical voltage. Each junction is only a few tens of microns in size so it is possible to place dozens of junctions in series in order to increase the voltage signal. Figure 15 on the right panel shows that there are two banks of thermoelectric sensors with the central common junctions supporting an enzyme gel. Thermopiles are thin film temperature sensors and are differential in nature in that they measure temperature differences, and are thus sensitive enough to detect exceedingly small temperature rises.

View the document record ↗ · Physical page 24, counting the cover.

EXCERPT 61 · PHYSICAL PAGE 25

D136, physical page 25: Figures 15 and 16, thermopile glucose sensor and catheter

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 8NI.¥ Thin Mylar Substrate Figure 15. Thermopile Glucose Sensor (left) With Functional Illustration (right) are Made Using Photolithographic Techniques. This large r device is about 8 mm i n length but has appro ximately 50 micron min imum geome tries. (Towe et al. ) At ASU the glucose sensor has been constructed on a thin mylar plastic substrate and so can be curved into a cylinder to form a small tube. This tube is then sensit ive to glucose concentrations on its outside exposure to the blood stream. Figure 16 shows a photograph and an illustration of a glucose sensor implemented in the form of a catheter. The electr ical output signal is routed by wires down the length of the catheter for a remote readout. The device was implanted in a p ig over a short duration and the decrease in blood glucose concentrations in response to admin istrat ion of insulin were recorded and are shown in the right hand panel of Figure 16. 10 min Figure 16. Photograph and Illustration of the Thermopile Glucose Sensor in a Catheter. Its configuration is shown (left) and its response in detect ing changes in blood glucose in a p ig as a result of insul in administ ration to t he animal. (ASU research.) Towe et al. This glucose sensor approach has been found to have limitations in stability when introduced into tissue or blood. Primarily the problems, as with many sensors, arise from the system chemistry and not as much from the electronic port ion of the sensor . The glucose oxidase enzyme slowly decays over time and thus the sensor sensitivity and calibration drifts making it eventually unusable. These problems have no easy solution. Investigators have been working with various forms of blood chemistry sensors for forty years or more. Microfabr icated UNCLASSIFIED/ {FOR OFFICIO! !Pfli ODIi.¥ 19
Check the original PDF
[Figure 15 labels: Antimony; Thin Mylar Substrate; Bismuth; Enzyme; Reference Junctions; Measuring Junctions; Reference Junctions] Figure 15. Thermopile Glucose Sensor (left) With Functional Illustration (right) are Made Using Photolithographic Techniques. This larger device is about 8 mm in length but has approximately 50 micron minimum geometries. (Towe et al.) At ASU the glucose sensor has been constructed on a thin mylar plastic substrate and so can be curved into a cylinder to form a small tube. This tube is then sensitive to glucose concentrations on its outside exposure to the blood stream. Figure 16 shows a photograph and an illustration of a glucose sensor implemented in the form of a catheter. The electrical output signal is routed by wires down the length of the catheter for a remote readout. The device was implanted in a pig over a short duration and the decrease in blood glucose concentrations in response to administration of insulin were recorded and are shown in the right hand panel of Figure 16. [Figure 16 labels: Glucose Catheter Sensor; Polyethylene tube; Thermopile; Enzyme Coating; Shielded wire; 3 mm; Epoxy; Ground Wire; Rolled Mylar with Polyurethane Foam Interior; Insulin; Concentration, mg%, 0 to 200; Time; 10 min] Figure 16. Photograph and Illustration of the Thermopile Glucose Sensor in a Catheter. Its configuration is shown (left) and its response in detecting changes in blood glucose in a pig as a result of insulin administration to the animal. (ASU research.) Towe et al. This glucose sensor approach has been found to have limitations in stability when introduced into tissue or blood. Primarily the problems, as with many sensors, arise from the system chemistry and not as much from the electronic portion of the sensor. The glucose oxidase enzyme slowly decays over time and thus the sensor sensitivity and calibration drifts making it eventually unusable. These problems have no easy solution. Investigators have been working with various forms of blood chemistry sensors for forty years or more. Microfabricated

View the document record ↗ · Physical page 25, counting the cover.

EXCERPT 62 · PHYSICAL PAGE 26

D136, physical page 26: BioMEMS neuroengineering, Figure 17 and bioelectric events

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 8NI.¥ thermoelectric sensors have improved reproducibility of the sensors, but there has only been limited success in applications of implantation into the body. Neuroengineering by BioMEMS BioMEMS types of devices, as we understand them today, were used first in neuroscience. There has been a long history of the study of the electrical nature of body tissue dating back to the days of Galvani and Volta. Frog nerves were found to be electrically stimulatable and the first recordings of bioelectrical events were accomplished very early with the invention of the string galvanometer. More recently, pointed wires inserted into muscle, nerve and brain have given way to MEMS electrode systems that are made on silicon supporting substrates and the processes of photolithography used to define electrical current pathways. Figure 17 shows a modern electrode system for detecting and recording electrical signals from living things. Each of the square regions is an exposed film of platinum while the thinner conductors that contact the pads are insulated by a thin layer of a plastic and conduct the detected electrical signals to a connector system (not shown). Figure 17. A MEMS Biopotential Electrode System. It is approximately 100 microns in width . Each square pad is an electr ically sensitive region. (Wikipedia) BIOELECTRIC EVENTS The living processes of biology can in some ways be likened to that of a battery. The metabolism of life produces the charging of the battery while it discharges through a myriad of bioelectrical events that produce movement, thought, and cognition. The transfer of electrical charge in the form of ions, mostly sodium, potassium and chloride is initiated by bioelectrically excitable cells of the nerves, muscles, and neurons of the brain. Collectively they constitute the wiring of the body. These ions result from the salts that are part of the composition of living things that have evolved from the sea. The movements of these ions constitutes the flow of an electrical current in tissues and are called bioelectrical currents. These currents give rise to electrical potentials that can be detected from the skin or by biopotential electrodes inserted into organs or muscle. UNCLASSIFIED/ {FOR OFFICIO! !Pfli ODIi.¥ 20
Check the original PDF
thermoelectric sensors have improved reproducibility of the sensors, but there has only been limited success in applications of implantation into the body. Neuroengineering by BioMEMS BioMEMS types of devices, as we understand them today, were used first in neuroscience. There has been a long history of the study of the electrical nature of body tissue dating back to the days of Galvani and Volta. Frog nerves were found to be electrically stimulatable and the first recordings of bioelectrical events were accomplished very early with the invention of the string galvanometer. More recently, pointed wires inserted into muscle, nerve and brain have given way to MEMS electrode systems that are made on silicon supporting substrates and the processes of photolithography used to define electrical current pathways. Figure 17 shows a modern electrode system for detecting and recording electrical signals from living things. Each of the square regions is an exposed film of platinum while the thinner conductors that contact the pads are insulated by a thin layer of a plastic and conduct the detected electrical signals to a connector system (not shown). Figure 17. A MEMS Biopotential Electrode System. It is approximately 100 microns in width. Each square pad is an electrically sensitive region. (Wikipedia) BIOELECTRIC EVENTS The living processes of biology can in some ways be likened to that of a battery. The metabolism of life produces the charging of the battery while it discharges through a myriad of bioelectrical events that produce movement, thought, and cognition. The transfer of electrical charge in the form of ions, mostly sodium, potassium and chloride is initiated by bioelectrically excitable cells of the nerves, muscles, and neurons of the brain. Collectively they constitute the wiring of the body. These ions result from the salts that are part of the composition of living things that have evolved from the sea. The movements of these ions constitutes the flow of an electrical current in tissues and are called bioelectrical currents. These currents give rise to electrical potentials that can be detected from the skin or by biopotential electrodes inserted into organs or muscle.

View the document record ↗ · Physical page 26, counting the cover.

EXCERPT 63 · PHYSICAL PAGE 27

D136, physical page 27: Figure 18, neural cell, and electrical interfaces with tissues

UNCLASSIFIED/ /P'OR: OP'Pl@IAL WS& 0NI.¥ Bioelectrical events are generated in tissues when there is an electrochemical change in the membranes of specialized cells of the brain and nervous systems. Neuroelectrical devices interface to the brain and nervous systems through electrodes that touch excitable cell membrane and convert ionic current flows to electron flow in a wire. Conversely current flows in a wire are converted by electrodes to ionic flows in tissue. The function of the entire human body is under control of the brain and the nervous system. So the use of electrodes of various types as a method of monitoring and controlling the function of the nervous system through bioelectrical currents and electrodes is potentially a very powerful method of treating in therapeutic ways. Figure 18 suggests the idea of an excitable cell of the brain having many tendrils or dendr ites that extend outward to interconnect with other cells. Essentially these cells are the relay points of the bioelectrical wiring of the human body. Figure 18. A Neural Cell Showing Dendritic Inter-Connections That are Electrically Active With Other Cells (artist's illustration) An electrical interface to body tissues typically occurs through the use of microelectrode systems. These electrodes are often on the order of tens of microns to millimeter-order in sizes depending on their function. For example electrodes that simply measure bioelectrical activity of the nervous system can resemble needles insulated along their length having micron order tips both because they carry only small electrical currents and also because they need to be placed in very specific places and they contact just a single or few cells that control specific functions. UNCLASSIFIED/ {FOR OFFICIO! !PEii ODIi.¥ 21
Check the original PDF
Bioelectrical events are generated in tissues when there is an electrochemical change in the membranes of specialized cells of the brain and nervous systems. Neuroelectrical devices interface to the brain and nervous systems through electrodes that touch excitable cell membrane and convert ionic current flows to electron flow in a wire. Conversely current flows in a wire are converted by electrodes to ionic flows in tissue. The function of the entire human body is under control of the brain and the nervous system. So the use of electrodes of various types as a method of monitoring and controlling the function of the nervous system through bioelectrical currents and electrodes is potentially a very powerful method of treating in therapeutic ways. Figure 18 suggests the idea of an excitable cell of the brain having many tendrils or dendrites that extend outward to interconnect with other cells. Essentially these cells are the relay points of the bioelectrical wiring of the human body. Figure 18. A Neural Cell Showing Dendritic Inter-Connections That are Electrically Active With Other Cells (artist's illustration) An electrical interface to body tissues typically occurs through the use of microelectrode systems. These electrodes are often on the order of tens of microns to millimeter-order in sizes depending on their function. For example electrodes that simply measure bioelectrical activity of the nervous system can resemble needles insulated along their length having micron order tips both because they carry only small electrical currents and also because they need to be placed in very specific places and they contact just a single or few cells that control specific functions.

View the document record ↗ · Physical page 27, counting the cover.

EXCERPT 64 · PHYSICAL PAGE 28

D136, physical page 28: bionics and neurointerfaces, Figure 19, and bioelectrodes

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ Bionics and Neurointerfaces Neuroprosthetics (also called neural prosthetics) is a discipline related to neuroscience and biomedical engineering concerned with developing neural prostheses. Neural prostheses are devices that attempt to substitute for a motor, sensory or cognitive modality that might have been damaged as a result of an injury or a disease. Bionics and neurointerfacing are relatively new concepts. A neurointerface is a combination of software and hardware that trans lates electrode signals to someth ing which is understood by an electronic system. The term bionics is used when we connect organic matter with something artificia l (human-made). The design and development of neural interface electrodes to the brain or peripheral nerve has been going on for more than twenty years. Figure 19 shows a mockup of a neuroprosthetic Figure 19. A Neuroprosthetic Interface. Adapted to the needs of a quadriplegic for control of his environmentselectrode system for the human brain (Duke University) that is meant to tap into brain signals and then through the use of a computer allow a quadr iplegic to control his environment. BIOELECTRODES AND BIOMEMS Electrodes that interface to the brain or nervous system are the most important components of neuroprosthet ic systems. There are basically of two classes of electrodes. One class does record ing of bioelectr ic events and the other provides current to stimulate bioelectrical responses. Both classes of electrodes need to be designed to be very robust for long term survival in the hostile environment of the human body. For this reason only the noble metals of platinum, iridium, gold, and to some extent the resistant metal tungsten are used for electrodes. Nearly all other metals would corrode in the warm saline environment of living tissues. Electronic exchange reactions occur at the electrode surfaces in both recording and stimulation modes. Many bioelectrodes are nothing more than fine wires insulated down their length and then exposed at a needle tip where an electrical contact exists to tissue. These are usually used in research for trying to understand brain function . Sometimes a single electrode performs both recording as well as stimulation but more frequently the electrode size and material is optimized to do one function or the other. UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ 22
Check the original PDF
Bionics and Neurointerfaces Neuroprosthetics (also called neural prosthetics) is a discipline related to neuroscience and biomedical engineering concerned with developing neural prostheses. Neural prostheses are devices that attempt to substitute for a motor, sensory or cognitive modality that might have been damaged as a result of an injury or a disease. Bionics and neurointerfacing are relatively new concepts. A neurointerface is a combination of software and hardware that translates electrode signals to something which is understood by an electronic system. The term bionics is used when we connect organic matter with something artificial (human-made). The design and development of neural interface electrodes to the brain or peripheral nerve has been going on for more than twenty years. Figure 19 shows a mockup of a neuroprosthetic electrode system for the human brain (Duke University) that is meant to tap into brain signals and then through the use of a computer allow a quadriplegic to control his environment. Figure 19. A Neuroprosthetic Interface. Adapted to the needs of a quadriplegic for control of his environments (Duke University) BIOELECTRODES AND BIOMEMS Electrodes that interface to the brain or nervous system are the most important components of neuroprosthetic systems. There are basically of two classes of electrodes. One class does recording of bioelectric events and the other provides current to stimulate bioelectrical responses. Both classes of electrodes need to be designed to be very robust for long term survival in the hostile environment of the human body. For this reason only the noble metals of platinum, iridium, gold, and to some extent the resistant metal tungsten are used for electrodes. Nearly all other metals would corrode in the warm saline environment of living tissues. Electronic exchange reactions occur at the electrode surfaces in both recording and stimulation modes. Many bioelectrodes are nothing more than fine wires insulated down their length and then exposed at a needle tip where an electrical contact exists to tissue. These are usually used in research for trying to understand brain function. Sometimes a single electrode performs both recording as well as stimulation but more frequently the electrode size and material is optimized to do one function or the other.

View the document record ↗ · Physical page 28, counting the cover.

EXCERPT 65 · PHYSICAL PAGE 29

D136, physical page 29: electrode arrays and Figure 20

UNCLASSIFIED/ /P"OR: OP"P"l@IAL WSli 01'11.¥ Electrode arrays are sometimes used, such as in the case of deep brain stimulation for late-stage Parkinson's disease, which is characterized by tremors of hands. There is a "brain pacemaker" that sends electrical impulses to specific parts of the patient's brain via permanently inserted electrodes. This can stop the tremors for reasons that are not exactly known and for which the best location in a given patient to place the electrode is also not known beforehand. Thus introducing multiple electrodes and stimulating each one in-turn until the best result is found allows a greater degree of possible effectiveness and therapeutic result. MEMS techniques are being employed in this application to permit a greater number of contacts and to reduce the size of the lead wire on the electrodes. MEMS multichannel electrode stimulating and recording electrode systems are also used in brain interface applications to record or stimulate the activity of many neural circuits. Such electrodes allow ability to record or stimulate complex muscle movements associated with the limb such as in walking or in grasping objects with the hands. Figure 20 shows an electrode system looking much like a bed of nails. Figure 20. Scanning Electron Micrograph of a Brain Electrode Array Manufactured From Titanium and Produced by a Process of Electrodischarge Machining ("Electrical Discharge Machining and Chemical Etching", Fofonoff * , Martel, Hatsopoulos, Donoghue, Hunter) All muscles of the body are activated by nerves that route to the brain. It is known from careful studies conducted by many investigators over the years that there is a wiring and physical mapping of the muscles to certain clusters of specialized cells in the motor cortex of the brain. It is also known that when a person plans or strongly imagines moving part of his body, there is a complex electrical activation of the corresponding regions of the brain involving many cells over a local area. UNCLASSIFIED/ (FOR OFFICJA 1 1155 01!1.¥ 23
Check the original PDF
Electrode arrays are sometimes used, such as in the case of deep brain stimulation for late-stage Parkinson's disease, which is characterized by tremors of hands. There is a "brain pacemaker" that sends electrical impulses to specific parts of the patient's brain via permanently inserted electrodes. This can stop the tremors for reasons that are not exactly known and for which the best location in a given patient to place the electrode is also not known beforehand. Thus introducing multiple electrodes and stimulating each one in-turn until the best result is found allows a greater degree of possible effectiveness and therapeutic result. MEMS techniques are being employed in this application to permit a greater number of contacts and to reduce the size of the lead wire on the electrodes. MEMS multichannel electrode stimulating and recording electrode systems are also used in brain interface applications to record or stimulate the activity of many neural circuits. Such electrodes allow ability to record or stimulate complex muscle movements associated with the limb such as in walking or in grasping objects with the hands. Figure 20 shows an electrode system looking much like a bed of nails. Figure 20. Scanning Electron Micrograph of a Brain Electrode Array Manufactured From Titanium and Produced by a Process of Electrodischarge Machining ("Electrical Discharge Machining and Chemical Etching", Fofonoff*, Martel, Hatsopoulos, Donoghue, Hunter) All muscles of the body are activated by nerves that route to the brain. It is known from careful studies conducted by many investigators over the years that there is a wiring and physical mapping of the muscles to certain clusters of specialized cells in the motor cortex of the brain. It is also known that when a person plans or strongly imagines moving part of his body, there is a complex electrical activation of the corresponding regions of the brain involving many cells over a local area.

View the document record ↗ · Physical page 29, counting the cover.

EXCERPT 66 · PHYSICAL PAGE 30

D136, physical page 30: fabrication of microelectrode arrays

UNCLASSIFIED/ /P'OR: OP'Pl@IAL WS& 0NI.¥ Over the years, investigators have figured out how to interpret precursor bioelectrical events in the brain involved in planning of movements. The result is that if enough recording electrodes are placed in the brain in the motor cortex area, it is possible to determine planned muscle motion. This works even if the muscles ultimately do not move, as in the case of a quadriplegic with spinal cord injury. Thus quite a remarkable possibility presents in that a computer program can be taught to interpret large numbers of bioelectrodes signals and so can determine a person's intent to move and then, for example, control a robotic limb that actually performs the operation. Crude forms of these thought-controlled devices have been shown in research laboratories to be feasible, even if they are at present not practical. Among other things, the electrode interface to the brain is not yet sufficiently developed to provide large numbers of functioning electrodes that can work over prolonged periods of time. MICROELECTRODE ARRAY FABRICATION Neuroengineering applications in the brain can require tens to hundreds of electrodes to make contact with a similarly large numbers of cells in the brain. Large numbers of electrodes in arrays inserted into the surface of the brain cortex thus become sensitive to the timing and patterns of cell firings. BioMEMS has been a critical part of this development. The electrode array in Figure 20 is made by a electrochemical process of using a long but stiff wire that acts like a machine tool. Electrical discharge machining (EDM) is a process that makes use of computer -aided design (CAD), that runs under computer numerical control (CNC), and that is capable of batch processing. A block of titanium metal that will ultimately be the array is placed in an electrolyte solution and the working electrode initiates a submerged electrochemical arc. It finely removes metal by a chemical process that does not involve a lot of heat. It can generate intricate features with high aspect ratios and is capable of machining a large variety of conductive materials. In this case, the electrode shaft thicknesses are on the order of 50-100 microns and the entire device is less than a centimeter square with 96 electrode channels. When this device is encapsulated in a polymer at its base and pressed into the brain cortex, each electrode then records from a specific set of neurons that are local to its placement. UNCLASSIFIED/ {FOR OFFICIO! !PEii ODIi.¥ 24
Check the original PDF
Over the years, investigators have figured out how to interpret precursor bioelectrical events in the brain involved in planning of movements. The result is that if enough recording electrodes are placed in the brain in the motor cortex area, it is possible to determine planned muscle motion. This works even if the muscles ultimately do not move, as in the case of a quadriplegic with spinal cord injury. Thus quite a remarkable possibility presents in that a computer program can be taught to interpret large numbers of bioelectrodes signals and so can determine a person's intent to move and then, for example, control a robotic limb that actually performs the operation. Crude forms of these thought-controlled devices have been shown in research laboratories to be feasible, even if they are at present not practical. Among other things, the electrode interface to the brain is not yet sufficiently developed to provide large numbers of functioning electrodes that can work over prolonged periods of time. MICROELECTRODE ARRAY FABRICATION Neuroengineering applications in the brain can require tens to hundreds of electrodes to make contact with a similarly large numbers of cells in the brain. Large numbers of electrodes in arrays inserted into the surface of the brain cortex thus become sensitive to the timing and patterns of cell firings. BioMEMS has been a critical part of this development. The electrode array in Figure 20 is made by a electrochemical process of using a long but stiff wire that acts like a machine tool. Electrical discharge machining (EDM) is a process that makes use of computer-aided design (CAD), that runs under computer numerical control (CNC), and that is capable of batch processing. A block of titanium metal that will ultimately be the array is placed in an electrolyte solution and the working electrode initiates a submerged electrochemical arc. It finely removes metal by a chemical process that does not involve a lot of heat. It can generate intricate features with high aspect ratios and is capable of machining a large variety of conductive materials. In this case, the electrode shaft thicknesses are on the order of 50-100 microns and the entire device is less than a centimeter square with 96 electrode channels. When this device is encapsulated in a polymer at its base and pressed into the brain cortex, each electrode then records from a specific set of neurons that are local to its placement.

View the document record ↗ · Physical page 30, counting the cover.

EXCERPT 67 · PHYSICAL PAGE 31

D136, physical page 31: brain-machine interfaces and Figure 21

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ BRAIN-MACHINE INTERFACES A specific development in MEMS based neuroengineering has been the brain-machine interface (BMI). These devices use computers to interpret brain signals from implanted neural arrays and then use the information to control machines and setup an automated environment. The development of such devices can have a profound impact on the quality of life for those individuals practically isolated because of their disabilities. Connected machines will enable them to enjoy the everyday things we take for granted . For example, a visual prosthesis could potentially restore partial vision to a blind patient by stimulating neurons in the visual cortex using an input BMI. Signals could be recorded from the motor cortex using an output BMI in order to bypass a neural injury and restore some movement to a paralyzed patient. Even a simpler device that would allow a patient to move a cursor on a screen would make a significant impact. It is generally recognized that clinical applications of such BMis may require the activities of hundreds or thousands of neurons to be simultaneously sampled. Figure 21 is an SEM photograph of a dense array of electrodes directed towards BMI applications. Figure 21. Scanning Electron Micrograph of a 1141 Electrode Array Made to Be Inserted Into the Surface of the Human Brain (University of Utah) A significant problem with these devices is that when they get too densely disposed, blood flow and disruption of the natural wiring of the brain causes decline of tissue function. Another very important issue is the biocompatibility of the material that the implants are coated with. The more biocompatible these materials are the less tissue reaction they will cause thus resulting less implant risk and longer implant period. UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ 25
Check the original PDF
BRAIN-MACHINE INTERFACES A specific development in MEMS based neuroengineering has been the brain-machine interface (BMI). These devices use computers to interpret brain signals from implanted neural arrays and then use the information to control machines and setup an automated environment. The development of such devices can have a profound impact on the quality of life for those individuals practically isolated because of their disabilities. Connected machines will enable them to enjoy the everyday things we take for granted. For example, a visual prosthesis could potentially restore partial vision to a blind patient by stimulating neurons in the visual cortex using an input BMI. Signals could be recorded from the motor cortex using an output BMI in order to bypass a neural injury and restore some movement to a paralyzed patient. Even a simpler device that would allow a patient to move a cursor on a screen would make a significant impact. It is generally recognized that clinical applications of such BMIs may require the activities of hundreds or thousands of neurons to be simultaneously sampled. Figure 21 is an SEM photograph of a dense array of electrodes directed towards BMI applications. Figure 21. Scanning Electron Micrograph of a 1141 Electrode Array Made to Be Inserted Into the Surface of the Human Brain (University of Utah) A significant problem with these devices is that when they get too densely disposed, blood flow and disruption of the natural wiring of the brain causes decline of tissue function. Another very important issue is the biocompatibility of the material that the implants are coated with. The more biocompatible these materials are the less tissue reaction they will cause thus resulting less implant risk and longer implant period.

View the document record ↗ · Physical page 31, counting the cover.

EXCERPT 68 · PHYSICAL PAGE 32

D136, physical page 32: polymer BioMEMS electrodes and Figure 22

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ POLYMER BIOMEMS ELECTRODES Polymer materials like polyimide are widely used for neuroprostheses because they are inert, flexible and metal films adhere well to them. Manufacturing of neural electrodes can be achieved by metal vacuum deposition through photolithographic masks and by a process of RF ablation or etching. Figure 22 shows some products of NeuroNexus Inc that result from this process. These electrodes are batch fabricated and have a high reproducibility of geometrical shape, electrical properties, and mechanical properties. Figure 22. Polymer-Based Cortical Penetrating Neuroelectrodes Made by Processes of Thin Film Deposition and RF Etching (Neuronexus Inc) They also have the advantage of small size, resulting in minimal displacement of the neural tissue and their long leg lengths give a high spatial resolution at various depths up to 1 cm. The multiple parallel shanks, provide horizontal spatial sampling and independent recording/stimu lation among sites. Figure 23 shows one of these devices introduced into the cortex of an exposed rat brain. UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ 26
Check the original PDF
POLYMER BIOMEMS ELECTRODES Polymer materials like polyimide are widely used for neuroprostheses because they are inert, flexible and metal films adhere well to them. Manufacturing of neural electrodes can be achieved by metal vacuum deposition through photolithographic masks and by a process of RF ablation or etching. Figure 22 shows some products of NeuroNexus Inc that result from this process. These electrodes are batch fabricated and have a high reproducibility of geometrical shape, electrical properties, and mechanical properties. Figure 22. Polymer-Based Cortical Penetrating Neuroelectrodes Made by Processes of Thin Film Deposition and RF Etching (Neuronexus Inc) They also have the advantage of small size, resulting in minimal displacement of the neural tissue and their long leg lengths give a high spatial resolution at various depths up to 1 cm. The multiple parallel shanks, provide horizontal spatial sampling and independent recording/stimulation among sites. Figure 23 shows one of these devices introduced into the cortex of an exposed rat brain.

View the document record ↗ · Physical page 32, counting the cover.

EXCERPT 69 · PHYSICAL PAGE 33

D136, physical page 33: Figure 23 and retinal devices that use BioMEMS

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ Figure 23. A MEMS Microelectrode Array Implanted Into the Cortex of a Rat Brain. The lead wires from the device can be seen . (NeuroNexus Inc.) RETINAL DEVICES USING BIOMEMS An example of MEMS being used in conjunction with wireless implantable systems is the retinal implant . These devices attempt to augment vision where it has failed due to problems such as macular degeneration and retinitis pigmentosa. The basic idea is to use a miniature video camera and connect it to an electrode array in the eye such that the scene in view is converted to electrical impulses used to stimulate the sensation of sight by direct stimulation of the receptors in the eye. Figure 24 shows this idea. Figure 25 shows a microe lectrode array that has been manufactured on a polymer substrate such that it is exceedingly thin and flexible. The flexibility is needed so that it conforms to the curved shape of the back of the eye. The electrode pads seen are attached by a flexible cable. UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ 27
Check the original PDF
Figure 23. A MEMS Microelectrode Array Implanted Into the Cortex of a Rat Brain. The lead wires from the device can be seen. (NeuroNexus Inc.) RETINAL DEVICES USING BIOMEMS An example of MEMS being used in conjunction with wireless implantable systems is the retinal implant. These devices attempt to augment vision where it has failed due to problems such as macular degeneration and retinitis pigmentosa. The basic idea is to use a miniature video camera and connect it to an electrode array in the eye such that the scene in view is converted to electrical impulses used to stimulate the sensation of sight by direct stimulation of the receptors in the eye. Figure 24 shows this idea. Figure 25 shows a microelectrode array that has been manufactured on a polymer substrate such that it is exceedingly thin and flexible. The flexibility is needed so that it conforms to the curved shape of the back of the eye. The electrode pads seen are attached by a flexible cable.

View the document record ↗ · Physical page 33, counting the cover.

EXCERPT 70 · PHYSICAL PAGE 34

D136, physical page 34: Figures 24 and 25, retinal prosthesis and retinal array

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ Figure 24. A Representation of the Retinal Prosthesis: (A) camera in the glass frame, (B) wireless transmitter, (C) extraocular electronic case (receiver), and (D) intraocular implant electrode array (http ://b iomed .brown .edu/Cou rses/BI108/2006 - 108websites/group03retinal implants/ interoccular . htm) Figure 25. A BioMEMS-Fabricated 4x4 Microelectrode Retinal Array (http ://biomed.brown.edu/Courses/BI 108/2006- 10Swebsites/ group03retinalimplants/interoccular .htm) A retinal based neuroprost hesis is designed to use electrical pulse stimulation of the remaining viable retinal cells to evoke the sensation of light at discrete points within the visual field. These apparent points of light are called phosphenes. The strategy is to pulse the retina with sufficiently close-spaced electrodes such that the phosphenes would combine to present an organized pattern to the patient's perceptions. A completely implanted device is desired that has the electrode array connected to a pulse driver circuit, power, and signal processing. All of these components must be miniaturized as much as possible so the entire device can be implanted. Microimplantable devices based on BioMEMS structures are being developed that capture their power from outside the body by wireless techniques. Bidirectional communication is often needed to provide feedback on device function. Some communication links need a wide bandwidth for real-time data transm ission and this is challenging since such types of communicat ion are inherently of a high power drain . Figure 26 is an artist's conception of the ret inal implant designed by the Boston group. UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ 28
Check the original PDF
[Figure 24 labels: A; B; C; D] Figure 24. A Representation of the Retinal Prosthesis: (A) camera in the glass frame, (B) wireless transmitter, (C) extraocular electronic case (receiver), and (D) intraocular implant electrode array (http://biomed.brown.edu/Courses/BI108/2006-108websites/group03retinalimplants/interoccular.htm) Figure 25. A BioMEMS-Fabricated 4x4 Microelectrode Retinal Array (http://biomed.brown.edu/Courses/BI108/2006-108websites/group03retinalimplants/interoccular.htm) A retinal based neuroprosthesis is designed to use electrical pulse stimulation of the remaining viable retinal cells to evoke the sensation of light at discrete points within the visual field. These apparent points of light are called phosphenes. The strategy is to pulse the retina with sufficiently close-spaced electrodes such that the phosphenes would combine to present an organized pattern to the patient's perceptions. A completely implanted device is desired that has the electrode array connected to a pulse driver circuit, power, and signal processing. All of these components must be miniaturized as much as possible so the entire device can be implanted. Microimplantable devices based on BioMEMS structures are being developed that capture their power from outside the body by wireless techniques. Bidirectional communication is often needed to provide feedback on device function. Some communication links need a wide bandwidth for real-time data transmission and this is challenging since such types of communication are inherently of a high power drain. Figure 26 is an artist's conception of the retinal implant designed by the Boston group.

View the document record ↗ · Physical page 34, counting the cover.

EXCERPT 71 · PHYSICAL PAGE 35

D136, physical page 35: Figure 26, Boston retinal neuroprosthesis, and inductive power transfer

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ Figure 26. An Illustration of the Retinal Neuroprosthesis Created by the Boston Implant Project (http://www. bostonret inaIi mp lant.erg/implant. php ?fontsize= norm a l&h i contrast) The signal processing circuits are on the lelt while the power induction coil is the circular structure. The MEMS stimulating microelectrode array projects out towards the bottom of the picture. The minimal size of the implant means batteries are impractical and forms of wireless power by magnetic induction, ultrasound, or solar energy are required. In addit ion the tissue surrounding the implant is usually very sensitive to temperature rise so the implant must have very low power consumption to ensure it will not harm the tissue. Power by magnetic inductio n is widely used because it allows relatively larger amounts of power transfer compared to ultrasound and solar energy techniques. Parallel coils of wire, one inside the body and one outside, exchange energy by magnetic field coupling in accordance with Faraday's law of induction. Figure 27 is an artist's conception of the magnetic induction method of power transmission. There are two coaxial coils that couple magnetically, one on the inside of the body and one external. The energy of the magnetic field is shown as the curved lines passing through the tissue. A disadvantage of this method is that the coils are relati vely large compared to the size of micro-implants and so tends to define the minimum size. The coil size depends on the amount of energy that needs to be ind uced and on the implant depth with larger diameter coils being required. This type of technology is giving way to improved methods of energy transmission into tissue for implant power by using microscale devices that, although not strictly MEMS, share many of their characteristics. UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ 29
Check the original PDF
Figure 26. An Illustration of the Retinal Neuroprosthesis Created by the Boston Implant Project (http://www.bostonretinalimplant.org/implant.php?fontsize=normal&hicontrast) The signal processing circuits are on the left while the power induction coil is the circular structure. The MEMS stimulating microelectrode array projects out towards the bottom of the picture. The minimal size of the implant means batteries are impractical and forms of wireless power by magnetic induction, ultrasound, or solar energy are required. In addition the tissue surrounding the implant is usually very sensitive to temperature rise so the implant must have very low power consumption to ensure it will not harm the tissue. Power by magnetic induction is widely used because it allows relatively larger amounts of power transfer compared to ultrasound and solar energy techniques. Parallel coils of wire, one inside the body and one outside, exchange energy by magnetic field coupling in accordance with Faraday's law of induction. Figure 27 is an artist's conception of the magnetic induction method of power transmission. There are two coaxial coils that couple magnetically, one on the inside of the body and one external. The energy of the magnetic field is shown as the curved lines passing through the tissue. A disadvantage of this method is that the coils are relatively large compared to the size of micro-implants and so tends to define the minimum size. The coil size depends on the amount of energy that needs to be induced and on the implant depth with larger diameter coils being required. This type of technology is giving way to improved methods of energy transmission into tissue for implant power by using microscale devices that, although not strictly MEMS, share many of their characteristics.

View the document record ↗ · Physical page 35, counting the cover.

EXCERPT 72 · PHYSICAL PAGE 36

D136, physical page 36: Figure 27 and the microscale in therapeutic neurostimulation

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ Figure 27. Power Transfer by Magnetic Induction to an Implanted BioMEMS Retinal Prosthesis. This is the Boston Retinal Implant Project. (http://www. bostonretina Iim plant. org/ retina I approach. php ?fontsize= norm al&hicontrast) MICROSCALE IN THERAPEUTIC NEUROSTIMULATION Some of the biggest excitement in medical neuroprosthetics has been in the notion that we can use micro-implantable devices rather than drugs to reduce or better control the effects of stroke, heart disease, epilepsy, and other disorders of the human condition. Bioelectrical stimulation has effects which are very specific on local tissues rather than indiscriminately affecting all tissues and so may offer fewer side effects of drugs. Such devices can be finely controlled in their effects and provide a greater flexibility in terms of treatment. Any implanted device has to be small in order to be minimally invasive, especially in the brain. Powering of implanted devices by batter ies is only practical in a few biomedical situations. Also implants may need to communicate with the outside world wirelessly. Having wires penetrating the skin is uncomfortab le and could lead to infection in the tissue. The notion of placing bioelectronic stimulation devices inside of the body for therapeutic reasons goes back to the early invention of the pacemaker. These kind of devices have internal batteries to support an electrical pulse generator that paces the rhythm of the heart. Because the amount of energy in each pulse is relatively small the power drain is low and the pacemaker batteries can last years. The difficulty is that they are bulky, must be eventually replaced on the order of seven years, and their placement is invasive. UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ 30
Check the original PDF
[Figure 27 labels: Chip and electrode array connected to Coil (see next figure); Receiving Coil for data and power; Transmission Coil for data and power (wireless transmission); CCD; Miniature camera mounted on a pair of glasses (sends image to transmission coil)] Figure 27. Power Transfer by Magnetic Induction to an Implanted BioMEMS Retinal Prosthesis. This is the Boston Retinal Implant Project. (http://www.bostonretinalimplant.org/retinalapproach.php?fontsize=normal&hicontrast) MICROSCALE IN THERAPEUTIC NEUROSTIMULATION Some of the biggest excitement in medical neuroprosthetics has been in the notion that we can use micro-implantable devices rather than drugs to reduce or better control the effects of stroke, heart disease, epilepsy, and other disorders of the human condition. Bioelectrical stimulation has effects which are very specific on local tissues rather than indiscriminately affecting all tissues and so may offer fewer side effects of drugs. Such devices can be finely controlled in their effects and provide a greater flexibility in terms of treatment. Any implanted device has to be small in order to be minimally invasive, especially in the brain. Powering of implanted devices by batteries is only practical in a few biomedical situations. Also implants may need to communicate with the outside world wirelessly. Having wires penetrating the skin is uncomfortable and could lead to infection in the tissue. The notion of placing bioelectronic stimulation devices inside of the body for therapeutic reasons goes back to the early invention of the pacemaker. These kind of devices have internal batteries to support an electrical pulse generator that paces the rhythm of the heart. Because the amount of energy in each pulse is relatively small the power drain is low and the pacemaker batteries can last years. The difficulty is that they are bulky, must be eventually replaced on the order of seven years, and their placement is invasive.

View the document record ↗ · Physical page 36, counting the cover.

EXCERPT 73 · PHYSICAL PAGE 37

D136, physical page 37: ultrasound-powered neurostimulators and Figure 28

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ Variations of pacemaker devices are used in brain neurostimulation for treatment of Parkinson's disease characterized by the involuntary tremors of the hands and body. In this case the battery pack must be placed outside the brain, typically in the upper chest and a long catheter wire tunneled through tissues to the specific parts of the brain to be treated. Research at Arizona State University has been directed towards overcoming the problems of bulk and need for battery replacement through an approach where the implanted neurostimulation devices are made exceptionally small and where they derive their power by a process of induction from the outside of the body. Figure 28 shows one of these devices. The tiny size of the device reduces tissue trauma upon insertion. Small electrodes at either end of the device contact neural tissue and apply electrical stimulating pulses. The patient wears a type of powering­ Figure 28. A New Generation of Implantable patch on his body over the micro-implant Neurostimulation Devices Can Pass Through the and is supplied by a small cell-phone like Lumen of a Syringe Needle. This device was made at ASU and is powered by ultrasound energy. (Towe et al.)device having batteries that provides the energy for driving the patch. A coin-sized transducer on the skin directs ultrasound energy at about 1 MHz frequency towards an implanted microdevice. A type of piezoelectric plastic material known as PVDF is configured as a ultrasound receiver and works to change pulses of the sound wave energy into a rectified electrical current. This current is then used to stimulate tissues. Due to the fact that ultrasound is a mechanical vibration and carries significant energy in a vibrating wave, the energy transfer across the skin can be more easily achieved than magnetic induction to a similar depth and size and so provide the needed currents for neurostimulat ion. Figure 29 shows a bioelectrical stimulator configuration. The implanted device is 0.9 mm x 1.2 mm and conta ins a Schottky diode . The piezoelectric output current response of PVDF to the ultrasound is increased by stacking thin 25 micron sheets of the material connected so they are in electrical parallel . With bonding layer thicknesses in-between, the overall thickness of the stack is on the order of 250-350 microns and forms a solid structure. UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ 31
Check the original PDF
Variations of pacemaker devices are used in brain neurostimulation for treatment of Parkinson's disease characterized by the involuntary tremors of the hands and body. In this case the battery pack must be placed outside the brain, typically in the upper chest and a long catheter wire tunneled through tissues to the specific parts of the brain to be treated. Research at Arizona State University has been directed towards overcoming the problems of bulk and need for battery replacement through an approach where the implanted neurostimulation devices are made exceptionally small and where they derive their power by a process of induction from the outside of the body. Figure 28 shows one of these devices. The tiny size of the device reduces tissue trauma upon insertion. Small electrodes at either end of the device contact neural tissue and apply electrical stimulating pulses. Figure 28. A New Generation of Implantable Neurostimulation Devices Can Pass Through the Lumen of a Syringe Needle. This device was made at ASU and is powered by ultrasound energy. (Towe et al.) The patient wears a type of powering-patch on his body over the micro-implant and is supplied by a small cell-phone like device having batteries that provides the energy for driving the patch. A coin-sized transducer on the skin directs ultrasound energy at about 1 MHz frequency towards an implanted microdevice. A type of piezoelectric plastic material known as PVDF is configured as a ultrasound receiver and works to change pulses of the sound wave energy into a rectified electrical current. This current is then used to stimulate tissues. Due to the fact that ultrasound is a mechanical vibration and carries significant energy in a vibrating wave, the energy transfer across the skin can be more easily achieved than magnetic induction to a similar depth and size and so provide the needed currents for neurostimulation. Figure 29 shows a bioelectrical stimulator configuration. The implanted device is 0.9 mm x 1.2 mm and contains a Schottky diode. The piezoelectric output current response of PVDF to the ultrasound is increased by stacking thin 25 micron sheets of the material connected so they are in electrical parallel. With bonding layer thicknesses in-between, the overall thickness of the stack is on the order of 250-350 microns and forms a solid structure.

View the document record ↗ · Physical page 37, counting the cover.

EXCERPT 74 · PHYSICAL PAGE 38

D136, physical page 38: Figure 29, ultrasound neurostimulator, MEMS in microfluidics and Figure 30

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 8NI.¥ Silver chloride electrodes (0.8 mm) encapsulation Diode piezoelectric polymer (0.9mm) (variable length 1-5 mm) Figure 29. Illustration of the Internal Construction of the Ultrasound Powered Neurostimulator Developed at ASU. Platinum ball electrodes at either end are the contacts to the tissue . (Towe et al.) This device has been implanted in rats and shown effective in neurostimulation under a wide variety of conditions. It appears suited to near-surface neurost imulations for relief of pain, and in the potential treatment of a variety of nervous system disorders. MEMS in Microfluidics Another major area of applicat ion of BioMEMS is the control of flu ids on very small scales and quantities. This capability is important in rapidly testing blood chemistry from single drops of whole blood, in the laboratory for clinical chemistry, and in working with very small amounts of DNA derived from cellular extracts. Manufacturing small channels that conduct fluids is relatively straight forward using photolithography. A computer generated optical mask is used to expose patterns onto photoresists, then a process of etching by plasma or chemicals is used to carve out parts of the substrate. Substrates are often glass since it is cheap, easily formed, and is a reasonably inert and biocompat ible surface. Figure 30 shows some of these kinds of configurations. Glass is easily etched by hydrofluor ic acid, but also forms of sandblasting with a fine grit have recently been developed to cut holes in glass. Finely carved capillaries in glass can allow nanoliters or even picoliters of fluid to UNCLASSIFIED/ {FOR OFFICIO! !Pfli ODIi.¥ Figure 30. Microfluidics in Glass. Microfluidics In glass take advantage of MEMS to produce microscale devices that can do complex chemical analysis. (http://www. i- micronews. com/interviews/M icronit ­ Microfluldics-d iscusses-product -diversificatio n. html) 32
Check the original PDF
[Figure 29 labels: encapsulation; Silver chloride electrodes (0.8 mm); Diode (0.9mm); piezoelectric polymer (variable length 1-5 mm)] Figure 29. Illustration of the Internal Construction of the Ultrasound Powered Neurostimulator Developed at ASU. Platinum ball electrodes at either end are the contacts to the tissue. (Towe et al.) This device has been implanted in rats and shown effective in neurostimulation under a wide variety of conditions. It appears suited to near-surface neurostimulations for relief of pain, and in the potential treatment of a variety of nervous system disorders. MEMS in Microfluidics Another major area of application of BioMEMS is the control of fluids on very small scales and quantities. This capability is important in rapidly testing blood chemistry from single drops of whole blood, in the laboratory for clinical chemistry, and in working with very small amounts of DNA derived from cellular extracts. Manufacturing small channels that conduct fluids is relatively straight forward using photolithography. A computer generated optical mask is used to expose patterns onto photoresists, then a process of etching by plasma or chemicals is used to carve out parts of the substrate. Substrates are often glass since it is cheap, easily formed, and is a reasonably inert and biocompatible surface. Figure 30 shows some of these kinds of configurations. Glass is easily etched by hydrofluoric acid, but also forms of sandblasting with a fine grit have recently been developed to cut holes in glass. Finely carved capillaries in glass can allow nanoliters or even picoliters of fluid to Figure 30. Microfluidics in Glass. Microfluidics in glass take advantage of MEMS to produce microscale devices that can do complex chemical analysis. (http://www.i-micronews.com/interviews/Micronit-Microfluidics-discusses-product-diversification.html)

View the document record ↗ · Physical page 38, counting the cover.

EXCERPT 75 · PHYSICAL PAGE 39

D136, physical page 39: labs-on-a-chip

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ move through the channels where processes of separation, filtering, mixing, heating, reaction, and waste disposal can occur in a programmed sequence . Color changes after a sequence of chemica l steps might be used to indicate the presence and concentration of an analyte. Optical absorbance or transparency can be read by a simple light emitting diode (LED) and photodetector system that measures light passing through the glass sample cell. LAB CHIPS A class of microflu idic devices known as lab-chips or Lab-on-a-Chip (LOC) have made their appearance in the market place. These devices are miniature chemical analysis systems that replace many of the manual and laborious steps associated with analytical chemistry. They are generally produced by MEMS techniques and often, but not always, incorpora te electrical systems on the devices. Automated MEMS-based lab-on-a-chip platforms have become an established system for basic life science research and drug discovery. They are used to assess the characteristics of isolated DNA or prote ins. One of the most useful products of bioMEMS instrumentation is the ability to manipulate small quantities of DNA using microfluidic pathways to perform chemistry with only the content from a single cell. BioMEMs enable new techniques in genomics (the study of sets of genes, gene products, and their interact ions) and proteomics (the study of proteins, the expression of genes in health and disease). These systems are being made now by companies includ ing Affymetix, Caliper, Nanogen, and Agilent for processing samples on a microflu idic chip for separation and detection. Figure 31 shows the variety of such systems currently on the market. Such devices can replace a number of gel electrophoresis operations and substantially improve work flow sample handling and analysis, lower per sample analys is by 10X and minimize sample and reagent use. The physics of these microfluidic systems enable some unique features, including smooth laminar flow t hrough the microchannels, high surface area to volume ratios, small thermal mass, and strong effects by electric fields. Microfluidic devices also lend themse lves to enhancements for single cell detection, fluorescence detection, sorting schemes, and unique fluid separation methods. The advantages of lab-on-chip devices include: • Improved fluid transport by electrokinetic effects and miniaturized pumps. • Efficient molecular and particle separation and immob ilizatio n. • Smaller sample requirements and carrier volumes. • Reduced reagent consumption and expense. • Integration of channels, mixers, separators, reaction chambers, electrodes, and detectors into single devices. UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ 33
Check the original PDF
move through the channels where processes of separation, filtering, mixing, heating, reaction, and waste disposal can occur in a programmed sequence. Color changes after a sequence of chemical steps might be used to indicate the presence and concentration of an analyte. Optical absorbance or transparency can be read by a simple light emitting diode (LED) and photodetector system that measures light passing through the glass sample cell. LAB CHIPS A class of microfluidic devices known as lab-chips or Lab-on-a-Chip (LOC) have made their appearance in the market place. These devices are miniature chemical analysis systems that replace many of the manual and laborious steps associated with analytical chemistry. They are generally produced by MEMS techniques and often, but not always, incorporate electrical systems on the devices. Automated MEMS-based lab-on-a-chip platforms have become an established system for basic life science research and drug discovery. They are used to assess the characteristics of isolated DNA or proteins. One of the most useful products of bioMEMS instrumentation is the ability to manipulate small quantities of DNA using microfluidic pathways to perform chemistry with only the content from a single cell. BioMEMs enable new techniques in genomics (the study of sets of genes, gene products, and their interactions) and proteomics (the study of proteins, the expression of genes in health and disease). These systems are being made now by companies including Affymetix, Caliper, Nanogen, and Agilent for processing samples on a microfluidic chip for separation and detection. Figure 31 shows the variety of such systems currently on the market. Such devices can replace a number of gel electrophoresis operations and substantially improve work flow sample handling and analysis, lower per sample analysis by 10X and minimize sample and reagent use. The physics of these microfluidic systems enable some unique features, including smooth laminar flow through the microchannels, high surface area to volume ratios, small thermal mass, and strong effects by electric fields. Microfluidic devices also lend themselves to enhancements for single cell detection, fluorescence detection, sorting schemes, and unique fluid separation methods. The advantages of lab-on-chip devices include: • Improved fluid transport by electrokinetic effects and miniaturized pumps. • Efficient molecular and particle separation and immobilization. • Smaller sample requirements and carrier volumes. • Reduced reagent consumption and expense. • Integration of channels, mixers, separators, reaction chambers, electrodes, and detectors into single devices.

View the document record ↗ · Physical page 39, counting the cover.

EXCERPT 76 · PHYSICAL PAGE 40

D136, physical page 40: Figure 31, commercial labs-on-a-chip, and NASA space applications

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ The a noChip(R) 400 cartridge ... oonstructs the user defined panel of e c arkers on one chip Figure 31. Commercial Lab-Chip Devices That Allow Analysis for Biomarkers of Various Diseases Using on-Chip Electrophoresis in Microscale (collage from manufacturers listed) These MEMS devices incorporate micro-scale fluidic components, sensors, actuators, and customized surfaces created by chemical modification or coating with inorganic and organic materials; enabling tissue engineering and cell patterning studies along with the microfluidic control of the culture environment. NASA SPACE APPLICATIONS FOR MICROFLUIDIC SYSTEMS NASA has supported at Arizona State University, the development of new types of microfluidic systems directed towards growing cell cultures on a chip. The specific application is detecting the effects of space flight and microgravity on living things at the cellular scale. Space presents a number of stresses on the cells of the astronaut's body from electromagnetic fields, microgravity, and space cabin environments, which in combination have effects that are likely different than any single stress. Beyond affecting the astronaut directly, space flig ht can change any organism, and actua lly makes some bacter ia more dangerous. Cells can be grown to represent the cells of the astronaut's body. Changes in DNA expression or molecular stress markers in cultured cells can be used to infer effects of space. Culturing mammalian cells in the laborat ory generally requires constant attendance and adjustment, but astronauts have little time for routine culture procedures. Thus NASA supported the desig n of an automated microfluidic system to perform all the steps UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ 34
Check the original PDF
[Figure 31 labels: www.nanogen.com; The NanoChip(R) 400 cartridge ... constructs the user defined panel of genetic markers on one chip; Affymetrix, www.affymetrix.com; Caliper Technologies, www.calipertech.com; Aclara Biosciences] Figure 31. Commercial Lab-Chip Devices That Allow Analysis for Biomarkers of Various Diseases Using on-Chip Electrophoresis in Microscale (collage from manufacturers listed) These MEMS devices incorporate micro-scale fluidic components, sensors, actuators, and customized surfaces created by chemical modification or coating with inorganic and organic materials; enabling tissue engineering and cell patterning studies along with the microfluidic control of the culture environment. NASA SPACE APPLICATIONS FOR MICROFLUIDIC SYSTEMS NASA has supported at Arizona State University, the development of new types of microfluidic systems directed towards growing cell cultures on a chip. The specific application is detecting the effects of space flight and microgravity on living things at the cellular scale. Space presents a number of stresses on the cells of the astronaut's body from electromagnetic fields, microgravity, and space cabin environments, which in combination have effects that are likely different than any single stress. Beyond affecting the astronaut directly, space flight can change any organism, and actually makes some bacteria more dangerous. Cells can be grown to represent the cells of the astronaut's body. Changes in DNA expression or molecular stress markers in cultured cells can be used to infer effects of space. Culturing mammalian cells in the laboratory generally requires constant attendance and adjustment, but astronauts have little time for routine culture procedures. Thus NASA supported the design of an automated microfluidic system to perform all the steps

View the document record ↗ · Physical page 40, counting the cover.

EXCERPT 77 · PHYSICAL PAGE 41

D136, physical page 41: automated cell culture system and Figure 32

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 8NI.¥ needed to culture living cells, in volumes of less than a milliliter. The device contains thermopneumatic micropumps, microvalves, culture media reservoirs, cell culture chamber, and optical readout systems to detect fluorescent markers that the cells express when subjected to certain types of stress. Sensors for glucose, oxygen, and pH monitor the culture medium and work with a servo system to keep culture cond itions within a narrow range. One of the designed cell culture systems can be seen in Figure 32. The system is made from micromachined acrylic, and has fluidic pathways defined as channels in the plastic. The entire system is first laid out using a CAD (computer aided design) system and then machined to fine tolerances and chemically polished. r r Figure 32. Design of an Automated Cell Culture System for NASA Space Applications Incorporating Microfluidics and Integrated Optical Components (Towe et. al.) Figure 33 shows a more compact version of the device which contains two integrated optical cells designed to monitor the expression of green fluorescent protein (GFP) and UNCLASSIFIED/ {FOR OFFICIO! !Pfli ODIi.¥ 35
Check the original PDF
needed to culture living cells, in volumes of less than a milliliter. The device contains thermopneumatic micropumps, microvalves, culture media reservoirs, cell culture chamber, and optical readout systems to detect fluorescent markers that the cells express when subjected to certain types of stress. Sensors for glucose, oxygen, and pH monitor the culture medium and work with a servo system to keep culture conditions within a narrow range. One of the designed cell culture systems can be seen in Figure 32. The system is made from micromachined acrylic, and has fluidic pathways defined as channels in the plastic. The entire system is first laid out using a CAD (computer aided design) system and then machined to fine tolerances and chemically polished. Figure 32. Design of an Automated Cell Culture System for NASA Space Applications Incorporating Microfluidics and Integrated Optical Components (Towe et al.) Figure 33 shows a more compact version of the device which contains two integrated optical cells designed to monitor the expression of green fluorescent protein (GFP) and

View the document record ↗ · Physical page 41, counting the cover.

EXCERPT 78 · PHYSICAL PAGE 42

D136, physical page 42: Figure 33 and microcantilever MEMS sensors

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 8NI.¥ red fluorescent protein (RFP) in E. Coli bacterial cells genetically engineered by ASU microbiologist Dr. Valerie Stout. These bacteria glow when the rec-A gene is active, indicating a certain type of stress or damage to the bacteria due to the space environment. Figure 33. NASA Space Application of Microfluidic Cell Culture System Made by Micromachining (Towe - ASU research) Microcantilever MEMs Sensors The microcantilever is one of the simplest MEMS based biosensor devices, with wide applications in detection of very small amounts of specific chemicals through a process known as affinity sensing . This can detect gas composition, antigens in the air, toxic gases and particulates. The use of microcantilevers as transducers for chemical and biochemical sensing has only become widespread in the last few years, mainly due to their use in the development of microsensor arrays. The idea is quite simple: the surface of the cantilever, a thin rectangular beam clamped at one end, is chemically modified to react with specific compounds. The mass deposition that follows the chemical reaction causes a stress, and this leads to a detectable bending of the cantilever as illustrated in Figure 34. UNCLASSIFIED/ {FOR OFFICIO! !Pfli ODIi.¥ 36
Check the original PDF
red fluorescent protein (RFP) in E. Coli bacterial cells genetically engineered by ASU microbiologist Dr. Valerie Stout. These bacteria glow when the rec-A gene is active, indicating a certain type of stress or damage to the bacteria due to the space environment. Figure 33. NASA Space Application of Microfluidic Cell Culture System Made by Micromachining (Towe - ASU research) Microcantilever MEMs Sensors The microcantilever is one of the simplest MEMS based biosensor devices, with wide applications in detection of very small amounts of specific chemicals through a process known as affinity sensing. This can detect gas composition, antigens in the air, toxic gases and particulates. The use of microcantilevers as transducers for chemical and biochemical sensing has only become widespread in the last few years, mainly due to their use in the development of microsensor arrays. The idea is quite simple: the surface of the cantilever, a thin rectangular beam clamped at one end, is chemically modified to react with specific compounds. The mass deposition that follows the chemical reaction causes a stress, and this leads to a detectable bending of the cantilever as illustrated in Figure 34.

View the document record ↗ · Physical page 42, counting the cover.

EXCERPT 79 · PHYSICAL PAGE 43

D136, physical page 43: Figure 34, microcantilever principle, and static and vibrational sensors

UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥ Microcantilever based sensors fall into two categories: static sensors and vibrational sensors. Static sensing microcantilevers are usually covered with a gold film, which is then coated with a substance having a specific affin ity. Upon binding the specific selective chemical layer ~ L analyte (such as a prote in), stress is ------------------------------·-1 s generated result ing in bending of the microcantilever . The deflection is often measured using a narrow light beam from a small laser. ♦ reacting chemical compound Light reflected off the bottom of the cantilever falls onto a surface, where a position sensitive detector (PSD) can Figure 34. Principle of a Microcantilever That Bendsdetermine how much the beam bends. When It is Loaded With an Adherent Mass Typically the bend is exceedingly slight, but the sensitivity of the optical readout system is high enough that small amounts (nanograms to picograms) of adsorbed material can be detected. These devices are mostly used for measuring th ings in the air and not well suited for immersion in flu ids. In vibrational sensing, an external motor is used to vibrate the microcantilever through a certain range of speeds, and a sensing mechanism then reads out the amplitude of the vibration. By seeing at what speed the cantilever vibrates best, the resonant frequency is obta ined. As bioparticles bind to the microcantilever, the resonant frequency will be slower due to the increased mass. The mass of attached analyte can be determined from the frequency of the microcanti lever. The microcantilever has its own natural frequency w. When a biomolecule binds to the microcantilever, it changes the mass of the microcanti lever. This in turn affects the resonant frequency. We can use that change to determ ine the mass that has been attached to t he microcantilever. In some sense it is like a tuning fork that changes its pitch when touched. The surface has an affin ity for adhesion of a certain material and nothing else. When these materials are present, they adhere and increase the mass and so the pitch moves lower. The sensit ivity of these systems to the loaded mass increases as the mass of the cantilever beam decreases and with it the resonant frequency increases. Decreasing the overall dimensions of the beam results in an corresponding increase in their sensitivity. UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥ 37
Check the original PDF
Microcantilever based sensors fall into two categories: static sensors and vibrational sensors. Static sensing microcantilevers are usually covered with a gold film, which is then coated with a substance having a specific affinity. Upon binding the specific analyte (such as a protein), stress is generated resulting in bending of the microcantilever. [Figure 34 labels: selective chemical layer; h; L; s; reacting chemical compound] Figure 34. Principle of a Microcantilever That Bends When It is Loaded With an Adherent Mass The deflection is often measured using a narrow light beam from a small laser. Light reflected off the bottom of the cantilever falls onto a surface, where a position sensitive detector (PSD) can determine how much the beam bends. Typically the bend is exceedingly slight, but the sensitivity of the optical readout system is high enough that small amounts (nanograms to picograms) of adsorbed material can be detected. These devices are mostly used for measuring things in the air and not well suited for immersion in fluids. In vibrational sensing, an external motor is used to vibrate the microcantilever through a certain range of speeds, and a sensing mechanism then reads out the amplitude of the vibration. By seeing at what speed the cantilever vibrates best, the resonant frequency is obtained. As bioparticles bind to the microcantilever, the resonant frequency will be slower due to the increased mass. The mass of attached analyte can be determined from the frequency of the microcantilever. The microcantilever has its own natural frequency ω. When a biomolecule binds to the microcantilever, it changes the mass of the microcantilever. This in turn affects the resonant frequency. We can use that change to determine the mass that has been attached to the microcantilever. In some sense it is like a tuning fork that changes its pitch when touched. The surface has an affinity for adhesion of a certain material and nothing else. When these materials are present, they adhere and increase the mass and so the pitch moves lower. The sensitivity of these systems to the loaded mass increases as the mass of the cantilever beam decreases and with it the resonant frequency increases. Decreasing the overall dimensions of the beam results in an corresponding increase in their sensitivity.

View the document record ↗ · Physical page 43, counting the cover.

EXCERPT 80 · PHYSICAL PAGE 44

D136, physical page 44: Figures 35 and 36, microcantilevers and antibodies

UNCLASSIFIED/ /P'OR: OP'Pl@IAL WS& 0NI.¥ Thus the trend has been to employ MEMS technology to reduce the size of the cant ilever beams to microscopic proportions. In such cases, even the mass of cells or virus particles can be measured. Figure 35 shows a microcant ilever system that is on the order of one micron in widt h and 10 microns in length. This cantilever beam was used as a mass detector , with sensit ivity to a single vaccinia virus partic le (vaccinia virus forms the basis of the smallpox vaccine). Biomolecular sensors with the ability to "multiplex," or to detect a large number of different molecular species at the same time, are being developed for cancer diagnostics and therapy monitoring. The secret to good performance is finding a coating that has a high sensitivity for a specific material of interest. Antibodies are often used as coatings since they can be tailored to bind to many different molecules. Even so, there are olten problems of antibody shelf-life and they are not perfectly specific and so experience interference from other chemicals in the test sample. Figure 36 illustrates the affinity coating. Antibodies for different proteins are coated onto different micro-cantilever beams, making each beam a sensor. b r Tumour biomarker proteins 0 Figure 35. Scanning Electron Micrograph Showing a Cantilever Beam With a Single Vaccinia Virus Particle Anti ody Figure 36. Antibodies Attached to a Cantilever Array Create Different Specificities to Substances in Blood That are Indicative of Cancer UNCLASSIFIED/ (EAR OFFICIO! !Pfli 0111.¥ 38
Check the original PDF
Thus the trend has been to employ MEMS technology to reduce the size of the cantilever beams to microscopic proportions. In such cases, even the mass of cells or virus particles can be measured. Figure 35 shows a microcantilever system that is on the order of one micron in width and 10 microns in length. This cantilever beam was used as a mass detector, with sensitivity to a single vaccinia virus particle (vaccinia virus forms the basis of the smallpox vaccine). [Figure 35 labels: Vaccinia Virus Particle; Cantilever Beam; 1µm] Figure 35. Scanning Electron Micrograph Showing a Cantilever Beam With a Single Vaccinia Virus Particle Biomolecular sensors with the ability to "multiplex," or to detect a large number of different molecular species at the same time, are being developed for cancer diagnostics and therapy monitoring. The secret to good performance is finding a coating that has a high sensitivity for a specific material of interest. Antibodies are often used as coatings since they can be tailored to bind to many different molecules. Even so, there are often problems of antibody shelf-life and they are not perfectly specific and so experience interference from other chemicals in the test sample. Figure 36 illustrates the affinity coating. Antibodies for different proteins are coated onto different micro-cantilever beams, making each beam a sensor. [Figure 36 labels: b; Tumour biomarker proteins; Antibody; Bent cantilever] Figure 36. Antibodies Attached to a Cantilever Array Create Different Specificities to Substances in Blood That are Indicative of Cancer

View the document record ↗ · Physical page 44, counting the cover.

EXCERPT 81 · PHYSICAL PAGE 6

full page

UNCLASSIFIED/ /P91t 9Ffl@IAL YSIE 8HLY for robust construction of such an interface are optical stimulation, gating, and sensory devices, and chip-based electrode arrays that have been encased in ex-vivo-engineered neural tissue. UNCLASSIFIED/ /FOR. orrlEIAL U.!~ Gilt I vi

Editorial note: Introduction page of the DIA study, with the final sentence about components of a brain-machine interface.

Check the original PDF
UNCLASSIFIED/ /P91t 9Ffl@IAL YSIE 8HLY for robust construction of such an interface are optical stimulation, gating, and sensory devices, and chip-based electrode arrays that have been encased in ex-vivo-engineered neural tissue. UNCLASSIFIED/ /FOR. orrlEIAL U.!~ Gilt I vi

View the document record ↗ · Physical page 6, counting the cover.

Dates and documentary context

Event
23/03/2010 — Cover date of D130; D136 is dated March 31, 2010. ICOD of both: December 1, 2009.
Document
23/03/2010 — Covers, physical page 1 of each report.
Publication
Not established — Released in the DOW-UAP series of the U.S. Department of War.

Origin and release

Defense Intelligence Agency (DIA), Acquisition Support Division (DWO-3), AAWSAP program; D130 by “AAP Person 73”; D136 by “AAP Person 65” · DOW-UAP-D130_AAWSAP-DIRD-Technological-Approaches-to-Controlling-External-Devices-March-23-2010.pdf; DOW-UAP-D136_AAWSAP-DIRD-Biosensors-and-BioMEMS-A-Survey-of-the-Present-Field-March-31-2010.pdf

D130 pages 1, 2, 5, 6, 11, 33 and 34; D136 pages 1, 2, 6, 11 and 45.

Related accounts and their differences

Questions to continue the investigation

  • Did the program intend to apply these interfaces to the cockpit of advanced aircraft, as discussed in the DIRD on cockpits for breakthrough flight?

GEOGRAPHY OF THE CASE

Technical reports, no event location

Technical studies with no episode or observation site.

DOCUMENTARY TRAIL

Go back to the sources

References use physical pages of the PDF, counting the cover. Summaries are presented in English; the documents keep their original language.

  1. DOW-UAP-D130_AAWSAP-DIRD-Technological-Approaches-to-Controlling-External-Devices-March-23-2010.pdf

    Physical pages 1 and 2 (cover and masthead), 5 and 6 (introduction), 11 (Figure 2) and 33 and 34 (conclusions)

    DOW · 36 pages
  2. DOW-UAP-D136_AAWSAP-DIRD-Biosensors-and-BioMEMS-A-Survey-of-the-Present-Field-March-31-2010.pdf

    Physical pages 1 and 2 (cover and masthead), 6 (introduction), 11 (figures 2 and 3) and 45 (conclusion)

    DOW · 45 pages

Editorial summary based on the collection's research notes. How we read the documents.

ONE STORY LEADS TO ANOTHER

Keep exploring.

Back to the archive ↗
Cover with the DIA seal and the title of the report on warp drive and dark energy.Cover of official report

AAWSAP and advanced technologies2010Location: Reports prepared for the DIA's Acquisition Support Division (DWO-3), Washington, D.C., USA

Full dossier

DIA, 2010: two AAWSAP studies discuss, in theory, the “warp drive” and wormholes for faster-than-light travel

Two DIRDs from April 2010 review solutions of general relativity that would, in principle, allow faster-than-light travel: the Alcubierre warp bubble and traversable wormholes. Both require negative energy or “exotic matter” in quantities no one knows how to produce, and the authors themselves acknowledge that there are no instructions for building any of this.

Open the case
Cover with the DIA seal and the title Positron Aerospace Propulsion.Cover of official report

AAWSAP and advanced technologies2010Location: Reports prepared for the DIA's Acquisition Support Division (DWO-3), Washington, D.C., USA

Full dossier

DIA, 2010: AAWSAP studies propose positron-powered aircraft and spacecraft propelled by fusion microexplosions

Two DIRDs from March 2010 deal with extreme-energy propulsion using known physics. One proposes turbojets, missiles and rockets heated by positron annihilation and predicts a round-the-world flight within ten years; the other advocates spacecraft driven by small deuterium fusion explosions reflected by a magnetic mirror.

Open the case
Cover with the DIA seal and the title Invisibility Cloaking: Theory and Experiments.Cover of official report

AAWSAP and advanced technologies2010Location: Reports prepared for the DIA's Acquisition Support Division (DWO-3), Washington, D.C., USA

Full dossier

DIA, 2010: AAWSAP studies assess invisibility cloaks and metamaterials and conclude that hiding from visible light is still uncertain

Two DIRDs from 2010 review artificial materials capable of bending light and microwaves. One concludes that perfect cloaking is impossible and that only microwave invisibility was within reach of technology; the other sees metamaterials mainly as small, lightweight sensors and optical components for aerospace platforms.

Open the case

YOUR CHOICE

Cloudflare measures visits and performance without cookies, in aggregate statistics. Google Analytics only loads if you authorize it below. You can decline the optional items and browse the entire archive.

Read privacy policy